YTTW Mineral Insulated MI Cable 0.6/1kV To 33kV 5 Core Armoured Cable

Brand Name: JinHong
Model Number: YTTW
MOQ: 100m
Price: 10.5-25.99USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Conductormaterial:
Copper Or Aluminum
Cabletype:
Armored Or Unarmored
Sheathmaterial:
PVC, PE, Or LSZH
Maximumoperatingcurrent:
Depends On Cable Size And Type
Installationmethod:
Underground, Overhead, Or Direct Burial
Voltagerating:
0.6/1kV To 33kV
Numberofcores:
1 To 5 Cores
Application:
Power Distribution In Industrial Environments
Flameretardant:
Yes/No
Standardscompliance:
IEC, BS, UL, Or IEEE
Shielding:
Aluminum Foil Or Copper Tape
Temperaturerange:
-40°C To +90°C
Productname:
Industrial Power Cables
Insulationmaterial:
PVC, XLPE, Or Rubber
Bendingradius:
10 To 20 Times Cable Diameter
Highlight:

YTTW Mineral Insulated MI Cable

,

Mineral Insulated MI Cable 0.6/1kV

,

33kV 5 Core Armoured Cable

Product Description

YTTW Mineral Insulated (MI) Cable 0.6/1kV for Fire-Survival LV Power Circuits

YTTW Mineral-Insulated, Metal-Sheathed Low-Voltage Cable

YTTW is a mineral-insulated, metal-sheathed low-voltage cable typically used in applications where fire resistance and circuit continuity are critical for life safety and emergency power. It is the preferred choice for critical feeders in public buildings, transportation hubs, tunnels, and high-rise buildings.

Positioning Instructions

If your drawings require a reliable power supply under extreme temperature conditions, specify YTTW. For critical lines relying on reliable low-voltage power for evacuation, fire protection, and essential services, the MI (Mineral Insulation) construction is preferred.

Characteristics of YTTW

YTTW is typically supplied as a mineral-insulated (MI) metal-sheathed cable. Its primary insulation material is an inorganic mineral material within a metal sheath, rather than relying solely on polymer insulation. This design is widely used in emergency and life-safety circuits because it meets project requirements for circuit integrity and reliability under fire conditions. Depending on the installation environment, an outer protective layer can be specified to improve operability, abrasion resistance, and visibility.

Low Voltage Ratings
Typical Voltage Rating: 0.6/1 kV (depending on the project)
Typical Applications: Emergency feeders and critical low-voltage circuits
Selection Principles: Meet the fire performance requirements specified in your Bill of Quantities (BOQ) and Acceptance Schedule
Applications of YTTW
Life Safety and Emergency Applications
  • Power supply for fire pumps and sprinkler pumps
  • Smoke exhaust fans and booster systems
  • Emergency lighting and evacuation route circuits
  • Power supply for fire control rooms and critical monitoring
  • Emergency power distribution in high-rise building shafts and risers
  • Hospitals, command centers, data and communication rooms
  • Metro stations, tunnels, airports, railway hubs, and public places
Typical Installation Areas
  • Fireproof risers and service shafts
  • Basements, computer rooms, utility corridors, tunnels
  • Areas where smoke risk reduction and continuous circuit availability are prioritized (sheathing requirements depend on specifications)
Why Project Teams Should Purchase YTTW
Fire Performance of Critical Lines

MI design is ideal when the project prioritizes continuous circuit availability in harsh high-temperature environments specified in the project requirements.

Cleaner Public Space Safety Strategies

Projects typically combine MI cable lines with low-smoke installation strategies and appropriate outer sheath requirements to support evacuation and fire safety objectives.

Mechanical Strength of Fixed Lines

A properly installed metal sheath provides robust physical protection for many fixed installation environments.

Long-Lasting Design

YTTW is commonly used in critical lines where factors such as reliability, compliance, and reduced maintenance risks necessitate a higher-performance construction.

Structure Overview (Typical)
Conductor: Copper
Primary Insulation: Inorganic Mineral Insulation
Sheath: Metallic Sheath (depending on specific construction)
Outer Sheath: Optional Protective Outer Sheath (as specified)
Cable Type: Fixed-Insulation Mineral Insulated Cable for Emergency and Critical Low-Voltage Circuits
Process and Technical Specifications
  • Conductor Preparation
    Copper conductors are prepared to meet dimensional and resistance requirements.
  • Mineral Insulation Filling
    Inorganic mineral material is filled around the conductors to form the primary insulation system.
  • Sheath Forming and Sealing
    A metallic sheath is formed around the insulated core to provide sealing and protection. Compaction and Stabilization
  • Compaction and Stabilization
    The cable is compacted and stabilized to ensure its electrical performance and mechanical integrity.
  • Optional Outer Sheath
    A protective outer sheath can be applied to enhance visibility, abrasion resistance, and ease of handling during installation.
  • Routine Inspections
    Typical inspections include conductor resistance, electrical testing according to applicable standards, sheath continuity verification, dimensional checks, and visual inspections.
Common Specifications Overview
Common Number of Cores

1 core / 2 cores / 3 cores / 4 cores / 5 cores (depending on the project)

Common Cross-sectional Dimensions (mm²)

1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240

Examples of High-Demand Configurations
  • 1 core x 6
  • 1 core x 10
  • 1 core x 16
  • 2 cores x 2.5
  • 2 cores x 4
  • 3 cores x 2.5
  • 3 cores x 4
  • 3 cores x 6
  • 4 cores x 10
  • 4 cores x 16
  • 4 cores x 25
  • 5 cores x 10
  • 5 cores x 16
  • 5 cores x 25
Specification Table
Attribute Detail
Model YTTW
Category Mineral Insulation (MI) Metal-Sheathed Cables for Emergency and Critical Circuits
Typical Rated Voltage 0.6/1 kV (depending on project)
Conductor Copper
Primary Insulation Inorganic Mineral Insulation
Sheath Metallic Sheath (depending on construction)
Outer Sheath Optional, depending on line and acceptance specifications
Core Options 1/2/3/4/5 cores
Typical Size Range 1.5 to 240 mm² (depending on core wire and standard)
Typical Applications Fire pumps, smoke exhaust fans, emergency lighting, life safety power supplies, critical low-voltage feeders
Installation Fixed installation on designated emergency lines; external protection according to project design
Packaging Small-size cables are packaged in coils; suitable for large-size cables and reels for project delivery
Options Sheath type, marking language, identification method, length planning, documentation set, inspection support
Buyer's Choice List
  1. Confirm fire resistance requirements (duration/rating and test methods required in your bill of materials)
  2. Confirm voltage rating and system configuration
  3. Select core wire quantity based on circuit design and neutral/PE conductor layout
  4. Based on current and distance Select cross-sectional area based on permissible voltage drop and wiring conditions
  5. Determine if sheathing is required for your environment and identification scheme
  6. Confirm MI termination kit and accessory requirements for your project
  7. Plan lengths to minimize joints on critical lines
  8. Confirm required documentation and inspection requirements for approval and delivery
Quick Inquiry Template
Product: YTTW
Voltage Rating: __
Standard/Acceptance Criteria: __
Fire Resistance Requirements (Duration/Rating): __
Number of Cores: __
Size and Quantity: __
Total Length (meters): __
Installation Route: Riser/Shaft/Tunnel/Corridor/Computer Room
Sheath Required: Yes/No, Type: __
Destination: Country and Port: __
Trade Terms: __
Packaging: Roll/Cylinder
Recommended Length: __
Required Documents: __
Frequently Asked Questions
Question 1: What are the typical applications of YTTW?
Answer: YTTW is typically used in emergency and life safety circuits where project specifications require fire resistance and circuit continuity.
Question 2: Is YTTW suitable for fire pumps and smoke extraction systems?
A: Yes. YTTW is often specified for fire pumps, sprinkler pumps, smoke extraction fans, and booster systems when the design requires continuous operation of the emergency circuit.
Question 3: What are the typical low-voltage ratings?
A: Many projects specify YTTW for 0.6/1kV low-voltage systems, depending on local standards and project requirements.
Q4 Do I need an outer sheath?
A: Many installation projects require an outer sheath for abrasion protection, easy identification, and ease of handling. Whether an outer sheath is needed depends on the line route, environment, and acceptance criteria.
Q5 What are the key points for installation and termination?
A: Insulated cables typically require compatible termination kits and proper installation techniques to maintain sheath continuity and insulation integrity. Please confirm the accessory system required for the project.
Q6 What details will help you provide an accurate quote?
A. Voltage rating, fire resistance requirements, number of conductors, specification list, total length (meters), line type, whether an outer sheath is required, destination, packaging preferences, and required documents.
Service of JinHong Company
Over Productions Service:

JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

Quality Certification Services:

JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

Profession Customer Service:

JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

Delivery And Shipping Services:

While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.