products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Low Voltage Cable
Created with Pixso.

XLPE LSZH Steel Tape Armored Cable WDZ-YJY23 For Underground LV Feeds

XLPE LSZH Steel Tape Armored Cable WDZ-YJY23 For Underground LV Feeds

Brand Name: JinHong
Model Number: WDZ-YJY23
MOQ: 100m
Price: 10-15.99USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Temperaturerange:
-40°C To +90°C
Cabletype:
Single Core, Multi Core
Conductormaterial:
Copper Or Aluminum
Armortype:
Steel Wire Armor (SWA) Or Steel Tape Armor (STA)
Installationenvironment:
Underground, Indoor, Outdoor, Or Submarine
Waterresistance:
Water Resistant Or Water Proof
Standardscompliance:
IEC, BS, UL, Or IEEE Standards
Application:
Power Distribution In Industrial Plants, Factories, And Infrastructure
Productname:
Industrial Power Cables
Insulationmaterial:
XLPE (Cross-linked Polyethylene) Or PVC (Polyvinyl Chloride)
Flameretardant:
Yes
Numberofcores:
1, 2, 3, Or More
Sheathmaterial:
PVC, PE (Polyethylene), Or LSZH (Low Smoke Zero Halogen)
Voltagerating:
0.6/1kV, 3.6/6kV, 6/10kV, 8.7/15kV, 12/20kV
Maximumoperatingvoltage:
Up To 35kV For Medium Voltage Cables
Highlight:

LSZH Steel Tape Armored Cable

,

XLPE LSZH Armored Cable

,

Steel Tape Armored Cable WDZ-YJY23

Product Description

WDZ-YJY23 LSZH Steel-Tape Armored XLPE Cable for Underground LV Feeds

WDZ-YJY23 Product Details

WDZ-YJY23 is a low-smoke halogen-free steel-tape armored cross-linked polyethylene (XLPE) insulated copper core power cable suitable for 0.6/1kV fixed installations. It is ideal for applications requiring low-smoke halogen-free performance and mechanical protection, such as conduits, trenches, and utility corridors.

Product Highlights

WDZ-YJY23 utilizes low-smoke halogen-free materials and steel tape armor to provide stronger protection and enhanced fire resistance for your low-voltage feeder lines, helping your underground and conduit installations meet modern safety and durability requirements.

Product Overview

WDZ-YJY23 is a low-voltage copper core power cable designed for fixed installations where high safety and mechanical reliability are required. It typically features stranded copper conductors, cross-linked polyethylene (XLPE) insulation, an inner liner, steel tape armor, and a low-smoke halogen-free outer sheath system. The Low Smoke Halogen-Free (LSZH) sheath is designed to reduce smoke concentration during fires and prevent the generation of corrosive halogen gases, while the steel tape armor enhances the cable's resistance to compression and external mechanical stresses in conduits, trenches, basements, and utility corridors. This type of cable is commonly used in feeders, indoor-outdoor transitions, and long-distance distribution lines requiring stronger protection than unarmored LSZH power cables.

Low Voltage Ratings

  • Typical Rated Voltage: 0.6/1 kV
  • Applications: Fixed-installation low-voltage feeders, sub-feeders, and distribution lines
  • Item Notes: Please confirm relevant standards and any other testing requirements for the line type.

Applications of WDZ-YJY23

Common Applications

  • Low-voltage power distribution in underground conduits and trenches
  • Power lines in utility corridors, basements, and around buildings
  • Long-distance feeders in industrial parks and commercial facilities
  • Public infrastructure projects requiring Low Smoke Halogen-Free (LSZH) protection within enclosed corridors
  • Outdoor power distribution lines requiring additional mechanical protection
  • Feeder connections between transformer rooms, switch rooms, and main switchboards

Typical Installation Paths

  • Underground conduits and ducts
  • Trenches with protected and controlled backfill
  • Utility tunnels and service corridors
  • Protected outdoor fixed lines

Why Buyers Choose WDZ-YJY23

  • Low Smoke Halogen-Free (LSZH) Protection for Safer Enclosed Wiring

    Utilizing a Low Smoke Halogen-Free (LSZH) sheathing system reduces smoke and prevents the generation of corrosive halogen gases, thereby improving evacuation visibility and reducing the risk of corrosion to electrical equipment.

  • Steel tape armor provides protection against mechanical stress.

    The armor helps protect cables from the compression, impact, and external stresses common in underground ducts and trenches.

  • Cross-linked polyethylene (XLPE) insulation ensures stable performance of low-voltage feeders.

    XLPE insulation provides reliable dielectric properties and thermal stability, ensuring continuous operation of low-voltage lines.

  • More suitable for sourcing complex wiring configurations.

    The armored low-smoke halogen-free (LSZH) construction reduces line risk and helps meet the demands of projects with stringent installation conditions and high compliance requirements.

Structural Overview

  • Conductor: Copper stranded wire
  • Insulation: Cross-linked polyethylene (XLPE)
  • Backing Layer: Inner protective layer at the armor interface (depending on standard)
  • Armor: Steel tape armor (Type 23)
  • Outer Sheath: Low smoke halogen-free (LSZH)
  • Cable Type: Armored low-voltage power cable for fixed installation

Process and Manufacturing Notes

  • Copper Conductor Stranding and Resistance Control

    By controlling the stranding method, resistance is kept stable, improving the performance of long-distance feeders.

  • Cross-linked Polyethylene (XLPE) Insulation Extrusion and Cross-linking

    Extrusion and cross-linking processes are used to form a durable dielectric layer suitable for low-voltage power distribution.

  • Core Identification and Alignment

    Cores are identified and aligned to maintain cable geometry and improve conduit performance.

  • Backing Layer Application

    A backing layer is applied to protect the insulated cores and provide a stable base for the armor.

  • Steel Tape Armor

    Steel tape is wound using controlled overlap and tension to provide mechanical protection against compression and external stress.

  • Low-Smoke Halogen-Free Sheathing and Marking

    Applied with low-smoke halogen-free sheathing compound to ensure safety and environmental protection, and clearly marked for easy traceability.

  • Routine Inspections

    Typical inspections include conductor resistance, insulation thickness, spark testing, voltage testing, dimensional inspection, sheath integrity, and armor coverage verification.

General Specifications Overview

Common Core Wire Configurations (Depending on Project)

  • 2C for Single-Phase Distribution (Depending on Design)
  • 3C for Three-Phase Distribution Without Neutral (Depending on Design)
  • 4C for Three-Phase Distribution with Neutral (Common)
  • 5C for Three-Phase Distribution with Neutral and Protective Electrical Circuits (Depending on Design)
  • 1C Armored Single-Core Feeder Can Be Specified According to Design Specifications

Common Cross-Sectional Areas (mm²) for Armored Low-Voltage Lines

4 6 10 16 25 35 50 70 95 120 150 185 240 300

High-Frequency Underground Feeder Combinations

  • 4C x 10 4C x 16 4C x 25 4C x 35 4C x 50
  • 3C x 10 3C x 16 3C x 25 3C x 35
  • 5C x 10 5C x 16 5C x 25
  • 1 core x 70 1 core x 95 1 core x 120 1 core x 150

Specifications (can be copied directly)

Model WDZ-YJY23
Cable Type Low Smoke Halogen-Free (LSZH) Cross-linked Polyethylene (XLPE) Insulated Copper Armored Low Voltage Power Cable
Rated Voltage 0.6/1 kV
Conductor Copper Stranded Wire
Insulation Cross-linked Polyethylene (XLPE)
Armor Steel Tape (Type 23)
Outer Sheath Low Smoke Halogen-Free (LSZH)
Core Options 1 core, 2 cores, 3 cores, 4 cores, 5 cores (as needed)
Common Sizes 4 to 300 mm² (depending on the number of cores and standard)
Typical Operating Temperature Up to [temperature missing] for XLPE insulated cables 90°C (depending on standard)
Typical Installation Underground conduit, trench, utility corridor, protected outdoor wiring
Packaging Export reel (recommended for armored cables)
Customization Services Markup language, packaging marking, reel length options, documentation suite, inspection support

Selection Guide

  1. Confirm the type of installation route: Underground conduit, trench, utility corridor, or protected outdoor wiring
  2. Confirm the Low Smoke Halogen-Free (LSZH) requirements and acceptance criteria in the project standard
  3. Confirm the armor requirements: Type 23 steel tape armor
  4. Select the number of conductors based on the circuit design and neutral/protected wiring scheme
  5. Select the cross-sectional area based on current, installation route length, environmental or soil conditions, grouping, and voltage drop limitations
  6. Determine the recommended reel length to reduce the number of joints and speed up installation

Quick Inquiry Template

  • Product: WDZ-YJY23
  • Voltage: 0.6/1 kV
  • Required Standard: __
  • Low Smoke Halogen-Free (LSZH) Requirements: __
  • Core Configuration: __
  • Cross-sectional Area and Quantity: __
  • Total Length: __ meters
  • Laying Route Type: Underground Conduit/Trench/Utility Corridor/Protected Outdoor
  • Destination: Country and Port __
  • Trade Terms: __
  • Packaging: Drum
  • Preferred Drum Length: __
  • Required Documents: __
  • Remarks: Markup Language, Delivery Schedule, Inspection Requirements

Frequently Asked Questions

Q1 What is WDZ-YJY23 mainly used for?

A It is used for low-voltage fixed installations requiring low-smoke halogen-free (LSZH) performance and mechanical protection, especially suitable for underground conduits, trenches, and utility corridors.

Q2 What does "23" mean in WDZ-YJY23?

A "23" usually indicates a steel strip armored structure, which improves compressive strength and resistance to external mechanical stress.

Q3 What is the difference between WDZ-YJY23 and WDZ-YJY?

A WDZ-YJY is typically unarmored and used for protected building wiring; while WDZ-YJY23 adds steel tape armor and is suitable for underground and high-risk mechanical installation environments.

Q4 What voltage is WDZ-YJY23 used for?

A It is typically used as a 0.6/1kV low-voltage armored power cable for distribution and feeder circuits.

Q5 What are the commonly used specifications for underground low-voltage feeders?

A 10 to 50 mm² specifications are suitable for many building feeders, while 70 to 240 mm² and above are used for higher loads or longer routes, depending on voltage drop limitations.

Q6 What details will help you provide an accurate quote?

A Standards, Low Smoke Halogen-Free (LSZH) standards, conductor count, specification list, route type, total meters, reel length plan, destination, and documentation requirements.

Service of JinHong Company

  • Over Productions Service:

    JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

  • Quality Certification Services:

    JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

  • Profession Customer Service:

    JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

  • Delivery And Shipping Services:

    While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.