Water Resistant Low Voltage Cable ZR-YJV Fire Resistant Low Smoke Cables

Water Resistant Low Voltage Cable ZR-YJV Fire Resistant Low Smoke Cables

Brand Name: JinHong
Model Number: ZR-YJV
MOQ: 100m
Price: 12.5-25USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Installationmethod:
Underground, Overhead, Or Indoor
Sheathmaterial:
PVC Or PE
Waterresistance:
Water Resistant Or Waterproof
Cablesizerange:
1.5mm² To 1000mm²
Armortype:
Steel Wire Armor (SWA) Or Steel Tape Armor (STA)
Productname:
Industrial Power Cables
Operatingfrequency:
50Hz Or 60Hz
Cabletype:
Single Core Or Multi Core
Temperaturerange:
-40°C To +90°C
Flameretardant:
Yes/No
Standardscompliance:
IEC, BS, UL, Or IEEE
Conductormaterial:
Copper Or Aluminum
Application:
Power Distribution In Industrial Plants
Insulationmaterial:
PVC, XLPE, Or Rubber
Highlight:

Water Resistant Low Voltage Cable

,

Low Voltage Cable ZR-YJV

,

ZR-YJV Fire Resistant Low Smoke Cables

Product Description

Water Resistant Low Voltage Cable ZR-YJV Fire Resistant Low Smoke Cables

ZR-YJV is a 0.6/1kV copper core XLPE insulated, PVC sheathed low-voltage power cable with flame-retardant properties. It is suitable for building power distribution, cable trays, shafts, and utility corridors—locations requiring reduced flame spread risk and stable low-voltage power supply.

Standard YJV cables can be upgraded to flame-retardant versions without changing the installation logic. ZR-YJV retains the reliable performance of copper core + XLPE insulation while adding flame-retardant functionality, helping to limit flame spread along cable paths in densely populated building and industrial environments.

What is ZR-YJV?

ZR-YJV is the flame-retardant version of YJV:

  • YJV: Copper core, cross-linked polyethylene (XLPE) insulated, polyvinyl chloride (PVC) sheathed power cable
  • ZR: Flame retardant requirements (grade/category depends on project specifications and acceptance criteria)

It is suitable for fixed-installation low-voltage power distribution systems and is designed to reduce the spread of flame along cable trays, shafts, corridors, and other densely cabled paths.

Low Voltage Ratings
  • Typical Rated Voltage: 0.6/1 kV
  • Typical Applications: Low voltage feeders and distribution circuits
  • Installation Type: Fixed installation
Application Areas
Common Applications
  • Commercial buildings, residential buildings, and public places where flame-retardant cables are required.
  • Cable tray and trunking systems, with cables laid in groups.
  • Serving shafts, risers, and utility corridors, where limiting flame spread is a safety objective.
  • Industrial plants and warehouses, where cable lines pass through shared corridors and equipment rooms.
  • Renovation projects, upgrading standard YJV cables to flame-retardant cables.
When to Choose Other Cables
  • If low-smoke halogen-free cables must be used, specify the LSZH flame-retardant cable construction.
  • If emergency systems need to maintain circuit continuity under direct fire, specify fire-resistant cables.
  • If underground high-risk wiring requires strong mechanical protection, consider armored cables.
Why Buyers Specify ZR-YJV
  • Flame-retardant wiring safety

    Designed to limit the spread of flame along cable lines, provided that installation and testing meet the required acceptance level.

  • XLPE Insulation Performance

    XLPE insulation ensures stable dielectric properties and practical thermal performance suitable for low-voltage power distribution.

  • Procurement Efficiency

    Mainstream models, supporting common specifications, quick quotes available, and project bill of quantities can be integrated.

  • Easy Installation

    Maintains the same overall usage logic as standard YJV cables, simplifying replacement and upgrade decisions.

Structural Overview
  • Conductor: Copper stranded wire
  • Insulation: XLPE
  • Outer Sheath: PVC (flame retardant compound added upon request)
  • Armor: None (ZR-YJV; armored version to be specified separately)
  • Cable Type: Flame-retardant low-voltage power cable for fixed installation
Process and Manufacturing Notes
  • Copper Conductor Stranding

    The stranding method is controlled to achieve resistance targets and facilitate installation.

  • XLPE Insulation Layer Structure

    The insulation layer is extruded and cross-linked to form a stable dielectric layer suitable for low-voltage applications.

  • Core Assembly

    The cores are stacked to ensure stable cable geometry, suitable for cable trays, conduits, and shafts.

  • Flame-retardant Sheath Configuration

    The required flame-retardant rating is ensured through material selection and process control.

  • Sheath and Labeling

    PVC sheaths are used for protection and labeling, and printing is applied for traceability.

  • Routine Inspections

    Typical inspections include conductor resistance, insulation thickness control, electrical testing according to standards, dimensional inspection, and flame-retardant verification according to the acceptance plan.

Common Specifications Overview
Common Core Material Quantities
  • 1C / 2C / 3C / 4C / 5C (Depending on the project)
High-Demand Cross-Section Sizes (mm²)

1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

Common Project Combinations (Examples)
  • 3C x 10
  • 3C x 16
  • 3C x 25
  • 3C x 35
  • 4C x 10
  • 4C x 16
  • 4C x 25
  • 4C x 35
  • 4C x 50
  • 4C x 70
  • 4C x 95
  • 5C x 10
  • 5C x 16
  • 5C x 25
  • 1C x 120
  • 1C x 150
  • 1C x 240
Specifications Table (Can be copied directly)
Attribute Value
Model ZR-YJV
Rated Voltage 0.6/1 kV
Cable Type Flame-retardant copper conductor, XLPE insulation, PVC sheath low-voltage power cable
Conductor Copper, stranded
Insulation XLPE
Outer Sheath PVC (flame-retardant compound, according to required grade)
Armor None
Core Options 1 core/2 core/3 core/4 core/5 core
Typical Size Range 1.5 to 300 mm² (depending on core count and applicable standards)
Typical Applications Low-voltage distribution, feeders, cable trays, shafts, corridors, equipment rooms
Installation Method Fixed installation
Packaging Small-size cable reels; export-size large-size cable reels
Options Sheath color, marking language, core identification method, reel length planning, documentation package, inspection support
Buyer Selection Guide
  1. Confirm the flame retardant requirements and grade/class (ZR) in your Bill of Materials (BOQ)
  2. Confirm installation path (tray, shaft, corridor, conduit) and cable grouping.
  3. Select core quantity based on system design (neutral and PE conductor layout).
  4. Determine dimensions based on current carrying capacity and voltage drop (distance, grouping, environmental conditions, installation method).
  5. Plan length to reduce joints and improve path reliability.
  6. Confirm document package for approval and acceptance.
Quick Inquiry Template
Product:
ZR-YJV
Voltage:
0.6/1 kV
Standard/Requirement:
__
Flame Retardant Requirements (Rating/Category):
__
Core Quantity:
__
Cross-section and Quantity:
__
Total Length (meters):
__
Path:
Tray/Shaft/Corridor/Conduit/Indoor
Destination: Country and Port:
__
Trade Terms:
__
Packaging:
Coil/Reel
Preferred Reel Length:
__
Required Documents:
__
Special Requirements:
Marking Language/Sheath Color/Inspection/Delivery Schedule
Frequently Asked Questions (FAQ)
Q1 What are the uses of ZR-YJV?
A. It is used in low-voltage power distribution and feeder circuits, where flame retardant properties are crucial for limiting the spread of flame along cable paths (e.g., trays, risers, and corridors).
Q2. What does ZR mean?
A. ZR generally indicates a flame retardant requirement. The specific rating or category depends on project standards and acceptance criteria.
Q3. How is ZR-YJV different from YJV?
A. YJV is a standard copper core XLPE insulated PVC sheathed cable. ZR-YJV adds flame retardant materials and testing requirements to meet flame retardant acceptance criteria.
Q4. Is ZR-YJV suitable for cable trays and risers?
A. Yes, ZR-YJV is commonly used in cable trays, risers, corridors, and areas with dense wiring when flame retardant properties are required. Specific applications must comply with project standards and local regulations.
Q5. Is ZR-YJV low-smoke halogen-free?
A. Standard ZR-YJV uses a PVC sheath. If low-smoke halogen-free (LSZH) cable is required, specify LSZH flame-retardant cable instead of PVC sheath.
Q6. What information is needed for an accurate quote?
A. Required information includes: standards/guidelines, flame retardant rating requirements, conductor count, specification list, total meters, cabling type, destination, packaging requirements, and required documentation.
Service of JinHong Company
  • Over Productions Service:

    JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

  • Quality Certification Services:

    JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

  • Profession Customer Service:

    JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

  • Delivery And Shipping Services:

    While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.