VV Copper PVC/PVC Power Cable 0.6/1kV for Building Wiring and LV Distribution
Product Summary
Product Details
0.6/1kv low voltage cable
,35kv low voltage cable
Product Description
If you require a reliable low-voltage cable and your installers are familiar with its operation, VV cables are a safe and cost-effective option. VV cables feature copper conductors and a PVC/PVC construction, and are widely used in fixed installation wiring, distribution panel feeders, and general low-voltage power distribution in residential, commercial, and light industrial projects.
VV cables are low-voltage power cables, typically consisting of stranded copper conductors, PVC insulation, and a PVC outer sheath. They are designed for fixed installations in protected pathways such as conduits, cable trays, and cable ducts. VV cables are commonly used for building interior power distribution, branch circuits, and general low-voltage wiring, especially suitable for projects requiring no armor protection, low smoke halogen-free (LSZH), or fire-resistant ratings. Due to their wide range of specifications, stable supply, and ease of installation, VV cables are a popular standard product in cross-border procurement.
Typical Rated Voltage: 0.6/1 kV
Applications: Low-voltage power distribution and fixed wiring circuits
- Interior power distribution and branch circuits in buildings
- Lighting and socket wiring in conduit and cable tray systems
- Face-to-face connections and auxiliary feeders
- Cable trays and shafts for fixed installations
- Commercial premises, warehouses, residential developments, and general utilities
- Indoor fixed wiring and protected outdoor wiring
- Not recommended for repeated bending, dragging, or dynamic pulling operations
- For underground or high-mechanical-risk wiring, choose armored cables instead of VV cables
- Standardized and Widely Recognized
VV cables are a universal standard for building wiring and general low-voltage power distribution, facilitating Bill of Quantities (BOQ) matching and reducing substitution risks.
- Copper Conductor Reliability
Copper conductors provide stable conductivity and reliable termination for general power distribution circuits.
- PVC/PVC structure, easy installation
The PVC insulation and sheath are easy to peel, terminate, and handle on-site, helping installers work efficiently.
- Balanced pricing and availability
PVC products are widely produced and in ample stock to meet project schedules and repeat purchase needs.
- Conductor: Copper, stranded wire
- Insulation: PVC
- Outer Sheath: PVC
- Armor: None (Unarmored)
- Installation Type: Fixed installation, protective wiring
- Copper Conductor Drawing and Stranding
Copper is processed and stranded to meet resistance targets and ensure stable bending performance during installation.
- PVC Insulation Extrusion
The PVC insulation layer is extruded using a controlled thickness and concentricity process to ensure consistent dielectric properties.
- Core Identification and Wiring
Cores are identified and assembled with a stable geometry to maintain roundness and allow for smoother drawing.
- PVC Sheath and Marking
The PVC sheath enhances abrasion resistance and environmental protection performance and is suitable for typical building wiring. Marking is then applied for traceability.
- Routine Inspections
Routine inspections include conductor resistance, insulation thickness verification, spark testing, voltage testing, dimensional inspection, and sheath integrity.
- 1C Single-core Feeder and Dedicated Circuit
- 2C Single-phase Circuit
- 3C Three-phase Circuit without Neutral (Depending on Design)
- 4C Three-phase with Neutral (Common)
- 5C Three-phase with Neutral and Protective Power Supply (Depending on Design)
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
- 2C x 1.5 2C x 2.5 2C x 4
- 3C x 2.5 3C x 4 3C x 6
- 4C x 10 4C x 16 4C x 25 4C x 35 4C x 50
- 5C x 10 5C x 16 5C x 25
| Item | Details |
|---|---|
| Model | VV |
| Cable Type | Copper Core PVC Insulated PVC Sheathed Low-Voltage Power Cable |
| Rated Voltage | 0.6/1 kV |
| Conductor | Copper, Stranded |
| Insulation | PVC |
| Outer Sheath | PVC |
| Armor | None |
| Core Options | 1 Core 2 Cores 3 Cores 4 Cores 5 Cores |
| Common Size Range | 1.5 to 300 mm² (depending on core count and standard) |
| Typical Installation Methods | Conduit, Cable Tray, Reel, Shaft, Protected Circuit |
| Packaging | Smaller sizes are packaged in reels; larger sizes are packaged in export reels. |
| Options | Markup Language, Packaging Markings, Reel Length Diagram, Documentation Suite |
- When a project requires standard copper core low-voltage cable for fixed installation of protected circuits and does not require armor, select the VV model.
- Select the number of core wires based on circuit design, neutral requirements, and protective circuit layout.
- Select the appropriate cross-sectional area based on load current, line length, ambient temperature, grouping, and allowable voltage drop.
- If the line includes underground sections, presents a significant risk of compression, or is subject to high mechanical shock, armored cable should be selected.
- If the project requires flame retardancy, low smoke halogen-free (LSZH), or fire resistance, specify the required category to match different cable series.
- Product:
- VV
- Voltage:
- 0.6/1 kV
- Required Standard:
- __
- Core Wire Configuration:
- __
- Cross-section and Quantity:
- __
- Total Length:
- __ meters
- Installation Path:
- Conduit/Trough/Tray/Shaft/Outdoor Protection
- Destination Country and Port:
- __
- Trade Terms:
- __
- Packaging:
- Reel/Spool
- Spool Length Requirement:
- __
- Required Documents:
- __
- Remarks:
- Markup Language, Delivery Schedule, Inspection Requirements
- Q1 What are the uses of VV cables?
VV cables are used for fixed-installation low-voltage wiring and general power distribution, suitable for protected pathways such as conduits, cable trays, cable trays, and shafts.
- Q2 What is the typical rated voltage of a VV cable?
VV cables are typically supplied as 0.6/1 kV low-voltage power cables.
- Q3 Is VV cable suitable for underground installation?
VV cables are primarily used for protected pathways. For underground conduits, a protective layer can be used, but for high mechanical risks or direct burial, armored construction is usually specified.
- Q4 What is the difference between VV and YJV?
A VV uses PVC insulation, while YJV uses XLPE insulation. YJV is typically used in applications requiring higher thermal insulation, while VV is used for practical and cost-effective building wiring.
- Q5 What are the commonly used wire diameters in building projects?
A Branch circuits typically use wire diameters of 1.5 to 10 mm², while distribution lines typically use wire diameters of 16 to 50 mm², depending on the load and distance.
- Q6 What information is needed for a quick quote?
A Standard configuration, wire core configuration, wire gauge list, total meters, installation route, destination, packaging preferences, and documentation requirements.
- Over Productions Service:
JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.
- Quality Certification Services:
JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.
- Profession Customer Service:
JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.
- Delivery And Shipping Services:
While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.
JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.