products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Low Voltage Cable
Created with Pixso.

VV Copper PVC/PVC Power Cable 0.6/1kV for Building Wiring and LV Distribution

VV Copper PVC/PVC Power Cable 0.6/1kV for Building Wiring and LV Distribution

Brand Name: JinHong
Model Number: VV
MOQ: 100m
Price: 6.55-30.99USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Cable Type:
Armored, Unarmored
Installation Method:
Direct Burial, Cable Trays, Conduits
Standards Compliance:
IEC, BS, UL, IEEE
Flame Retardant:
Yes/No
Conductor Material:
Copper Or Aluminum
Insulation Material:
PVC, XLPE, Rubber
Application:
Power Distribution In Industrial Plants, Factories, Construction Sites
Temperature Range:
-40°C To +90°C
Sheath Material:
PVC, PE, LSZH
Voltage Rating:
0.6/1kV, 3.6/6kV, 6/10kV, Up To 35kV
Number Of Cores:
1, 2, 3, 4 Or More
Maximum Operating Voltage:
Up To 35kV
Shielding:
Aluminum Foil, Copper Tape, Or None
Mechanical Protection:
Steel Wire Armor, Steel Tape Armor
Highlight:

0.6/1kv low voltage cable

,

35kv low voltage cable

Product Description

If you require a reliable low-voltage cable and your installers are familiar with its operation, VV cables are a safe and cost-effective option. VV cables feature copper conductors and a PVC/PVC construction, and are widely used in fixed installation wiring, distribution panel feeders, and general low-voltage power distribution in residential, commercial, and light industrial projects.

Product Overview

VV cables are low-voltage power cables, typically consisting of stranded copper conductors, PVC insulation, and a PVC outer sheath. They are designed for fixed installations in protected pathways such as conduits, cable trays, and cable ducts. VV cables are commonly used for building interior power distribution, branch circuits, and general low-voltage wiring, especially suitable for projects requiring no armor protection, low smoke halogen-free (LSZH), or fire-resistant ratings. Due to their wide range of specifications, stable supply, and ease of installation, VV cables are a popular standard product in cross-border procurement.

Low Voltage Ratings

Typical Rated Voltage: 0.6/1 kV

Applications: Low-voltage power distribution and fixed wiring circuits

VV Cable Application Scenarios
Typical Applications
  • Interior power distribution and branch circuits in buildings
  • Lighting and socket wiring in conduit and cable tray systems
  • Face-to-face connections and auxiliary feeders
  • Cable trays and shafts for fixed installations
  • Commercial premises, warehouses, residential developments, and general utilities
Typical Wiring Conditions
  • Indoor fixed wiring and protected outdoor wiring
  • Not recommended for repeated bending, dragging, or dynamic pulling operations
  • For underground or high-mechanical-risk wiring, choose armored cables instead of VV cables
Reasons Buyers Choose VV Cables
  • Standardized and Widely Recognized

    VV cables are a universal standard for building wiring and general low-voltage power distribution, facilitating Bill of Quantities (BOQ) matching and reducing substitution risks.

  • Copper Conductor Reliability

    Copper conductors provide stable conductivity and reliable termination for general power distribution circuits.

  • PVC/PVC structure, easy installation

    The PVC insulation and sheath are easy to peel, terminate, and handle on-site, helping installers work efficiently.

  • Balanced pricing and availability

    PVC products are widely produced and in ample stock to meet project schedules and repeat purchase needs.

Structural Overview
  • Conductor: Copper, stranded wire
  • Insulation: PVC
  • Outer Sheath: PVC
  • Armor: None (Unarmored)
  • Installation Type: Fixed installation, protective wiring
Manufacturing and Process Description
  • Copper Conductor Drawing and Stranding

    Copper is processed and stranded to meet resistance targets and ensure stable bending performance during installation.

  • PVC Insulation Extrusion

    The PVC insulation layer is extruded using a controlled thickness and concentricity process to ensure consistent dielectric properties.

  • Core Identification and Wiring

    Cores are identified and assembled with a stable geometry to maintain roundness and allow for smoother drawing.

  • PVC Sheath and Marking

    The PVC sheath enhances abrasion resistance and environmental protection performance and is suitable for typical building wiring. Marking is then applied for traceability.

  • Routine Inspections

    Routine inspections include conductor resistance, insulation thickness verification, spark testing, voltage testing, dimensional inspection, and sheath integrity.

Common Specifications Overview
Common Core Wire Configurations (Depending on Project)
  • 1C Single-core Feeder and Dedicated Circuit
  • 2C Single-phase Circuit
  • 3C Three-phase Circuit without Neutral (Depending on Design)
  • 4C Three-phase with Neutral (Common)
  • 5C Three-phase with Neutral and Protective Power Supply (Depending on Design)
Common Cross-sectional Area (mm²)

1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

Common Building Power Distribution Combinations
  • 2C x 1.5 2C x 2.5 2C x 4
  • 3C x 2.5 3C x 4 3C x 6
  • 4C x 10 4C x 16 4C x 25 4C x 35 4C x 50
  • 5C x 10 5C x 16 5C x 25
Specifications
Item Details
Model VV
Cable Type Copper Core PVC Insulated PVC Sheathed Low-Voltage Power Cable
Rated Voltage 0.6/1 kV
Conductor Copper, Stranded
Insulation PVC
Outer Sheath PVC
Armor None
Core Options 1 Core 2 Cores 3 Cores 4 Cores 5 Cores
Common Size Range 1.5 to 300 mm² (depending on core count and standard)
Typical Installation Methods Conduit, Cable Tray, Reel, Shaft, Protected Circuit
Packaging Smaller sizes are packaged in reels; larger sizes are packaged in export reels.
Options Markup Language, Packaging Markings, Reel Length Diagram, Documentation Suite
Selection Guide
  1. When a project requires standard copper core low-voltage cable for fixed installation of protected circuits and does not require armor, select the VV model.
  2. Select the number of core wires based on circuit design, neutral requirements, and protective circuit layout.
  3. Select the appropriate cross-sectional area based on load current, line length, ambient temperature, grouping, and allowable voltage drop.
  4. If the line includes underground sections, presents a significant risk of compression, or is subject to high mechanical shock, armored cable should be selected.
  5. If the project requires flame retardancy, low smoke halogen-free (LSZH), or fire resistance, specify the required category to match different cable series.
Quick Inquiry Template
Product:
VV
Voltage:
0.6/1 kV
Required Standard:
__
Core Wire Configuration:
__
Cross-section and Quantity:
__
Total Length:
__ meters
Installation Path:
Conduit/Trough/Tray/Shaft/Outdoor Protection
Destination Country and Port:
__
Trade Terms:
__
Packaging:
Reel/Spool
Spool Length Requirement:
__
Required Documents:
__
Remarks:
Markup Language, Delivery Schedule, Inspection Requirements
Frequently Asked Questions
  • Q1 What are the uses of VV cables?

    VV cables are used for fixed-installation low-voltage wiring and general power distribution, suitable for protected pathways such as conduits, cable trays, cable trays, and shafts.

  • Q2 What is the typical rated voltage of a VV cable?

    VV cables are typically supplied as 0.6/1 kV low-voltage power cables.

  • Q3 Is VV cable suitable for underground installation?

    VV cables are primarily used for protected pathways. For underground conduits, a protective layer can be used, but for high mechanical risks or direct burial, armored construction is usually specified.

  • Q4 What is the difference between VV and YJV?

    A VV uses PVC insulation, while YJV uses XLPE insulation. YJV is typically used in applications requiring higher thermal insulation, while VV is used for practical and cost-effective building wiring.

  • Q5 What are the commonly used wire diameters in building projects?

    A Branch circuits typically use wire diameters of 1.5 to 10 mm², while distribution lines typically use wire diameters of 16 to 50 mm², depending on the load and distance.

  • Q6 What information is needed for a quick quote?

    A Standard configuration, wire core configuration, wire gauge list, total meters, installation route, destination, packaging preferences, and documentation requirements.

Service of JinHong Company
  • Over Productions Service:

    JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

  • Quality Certification Services:

    JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

  • Profession Customer Service:

    JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

  • Delivery And Shipping Services:

    While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.