products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Low Voltage Cable
Created with Pixso.

YTTW 0.6/1kV MI Cable 1000mm2 Conductor Low Voltage Wire 1 To 5 Cores

YTTW 0.6/1kV MI Cable 1000mm2 Conductor Low Voltage Wire 1 To 5 Cores

Brand Name: JinHong
Model Number: YTTW
MOQ: 200m
Price: 12.4-35USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Voltagerating:
600V To 35kV
Conductormaterial:
Copper Or Aluminum
Mechanicalprotection:
Steel Wire Armor, Steel Tape Armor
Maximumconductorsize:
Up To 1000 Mm²
Numberofcores:
1 To 5 Cores
Productname:
Industrial Power Cables
Sheathmaterial:
PVC, PE, LSZH
Insulationmaterial:
PVC, XLPE, EPR
Cabletype:
Armored, Unarmored, Flexible
Temperaturerating:
-40°C To 90°C
Application:
Industrial Machinery, Power Distribution
Flameretardant:
Yes/No
Standardscompliance:
IEC, BS, UL, IEEE
Shielding:
Aluminum Foil, Copper Tape
Installationenvironment:
Underground, Overhead, Indoor
Highlight:

YTTW 0.6/1kV MI Cable

,

1000mm2 Conductor Low Voltage Wire

,

MI Cable 1000mm2 Conductor

Product Description

YTTW MI Cable 0.6/1kV for Fire-Survival Low-Voltage Power and Life Safety

YTTW is a mineral-insulated, metal-sheathed low-voltage cable commonly used in fire-resistant circuits. It is specifically designed for applications with extremely high compliance and reliability requirements, such as emergency power supplies, fire pumps, smoke extraction systems, and life safety systems, ensuring circuit integrity.

For emergency circuits, downtime is unacceptable. If your project requires fire resistance, stable low-voltage power supply, and long-term reliability in high-rise buildings, transportation facilities, and public buildings, YTTW mineral-insulated cable is the ideal choice.

YTTW Introduction

YTTW is typically supplied as mineral-insulated (MI) cable with a metal sheath. Unlike standard polymer-insulated cables, MI cables use an inorganic mineral insulation layer as the primary medium, protected and isolated by a metal sheath. This structure is widely used in life safety and emergency systems because it maintains circuit integrity under harsh fire conditions and meets relevant acceptance standards. Depending on the route and environment, many projects also specify an outer sheath for identification, abrasion protection, and ease of installation.

Low Voltage Ratings
Typical Voltage Rating: 0.6/1 kV (depending on the project)
Typical Applications: Emergency feeders, critical power circuits, and life safety systems
Selection Basis: Meets the standards, test methods, and circuit integrity requirements specified in your Bill of Materials (BOQ)
Applications of YTTW
Life Safety and Emergency Systems
  • Fire pump power and sprinkler pump feeders
  • Smoke exhaust and booster fan feeders
  • Emergency lighting and evacuation routes
  • Fire control rooms and critical monitoring power
  • Elevator emergency power and critical vertical transport circuits
  • Hospitals, data centers, control centers, and critical service facilities
  • Subways, tunnels, airports, and transportation hubs with stringent fire safety regulations
  • Public buildings requiring low smoke and circuit continuity along specific emergency routes
Environmental Suitability
  • High-temperature risk paths and fire shafts
  • Basements, service tunnels, and utility corridors
  • Site conditions requiring enhanced flame retardancy, heat resistance, and harsh environmental performance (depending on the wiring)
Why Buyers Specify YTTW
  • Focus on Fire Integrity of Circuits For projects where specifications require critical circuits to operate continuously in fire environments, metallic insulation (MI) constructions are typically chosen.
  • Low Smoke Strategy in Public Areas (Outer Sheath Optional) Many projects opt for outer sheaths to meet low smoke and low toxicity requirements in enclosed spaces and evacuation routes.
  • High Mechanical Strength and Long Service Life Metallic sheath designs provide durable circuit protection and robust long-term stability for critical systems.
  • Compliance-Driven Procurement YTTW is often used when consultants and inspectors require recognized MI constructions for emergency services and life safety circuits.
Structure Overview (Typical)
  • Conductor: Copper
  • Insulation: Inorganic mineral insulation
  • Sheath: Metallic sheath (depending on construction)
  • Outer Sheath: Optional, depending on wiring and handling requirements
  • Armoring: Typically not required as the metallic sheath provides protection; external protection may be used depending on the circuit design.
  • Cable Type: MI Fire-Resistant Low-Voltage Cable for Fixed Installation
Process and Technical Specifications
  • Conductor Preparation Copper conductors require preparation to meet resistance and dimensional targets.
  • Mineral Insulation Filling and Compaction Inorganic mineral insulating material is filled around the conductors and compacted to form the primary insulation system.
  • Metal Sheath Forming A metal sheath is formed around the mineral-insulated core wires to provide sealing and protection.
  • Dimensional Control and Stabilization The cable's dimensions and stability must meet requirements to maintain consistent electrical performance and operation.
  • Outer Sheath (if specified) An outer sheath may be applied to provide abrasion protection, line marking, and ease of installation.
  • Routine Validation Typical checks include conductor resistance, insulation integrity testing, standard-compliant electrical testing, sheath continuity testing, dimensional checks, and visual inspection.
COMMON SPECIFICATIONS SUMMARY
Category Details
Common core counts 1C / 2C / 3C / 4C / 5C (project dependent)
Common cross-sections (mm2) frequently specified 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240
High-rotation configurations (examples) 1C x 4
1C x 6
1C x 10
1C x 16
2C x 2.5
2C x 4
2C x 6
3C x 2.5
3C x 4
3C x 6
4C x 10
4C x 16
4C x 25
5C x 10
5C x 16
5C x 25
SPECIFICATION TABLE (COPY-READY)
Model YTTW
Cable category mineral insulated (MI) metal-sheathed fire-survival LV power cable
Typical voltage grade 0.6/1 kV (project dependent)
Conductor copper
Primary insulation inorganic mineral insulation
Sheath metal sheath (construction dependent)
Outer oversheath optional, as specified
Core options 1C / 2C / 3C / 4C / 5C
Typical size range 1.5 to 240 mm2 (depends on core count and standard)
Typical applications fire pump feeders, smoke control fans, emergency lighting, life-safety and emergency circuits
Installation fixed installation on defined fire-rated routes; route protection per project design
Packing coils for small sizes; drums for larger sizes and project supply
Options oversheath type, marking language, identification color, length plan, documentation set, inspection support
BUYER SELECTION CHECKLIST
  1. Confirm the fire-survival requirement in the BOQ (integrity duration/class and test method)
  2. Confirm voltage grade and system configuration
  3. Choose core count based on circuit design and neutral/PE plan
  4. Size cross-section by current, distance, voltage drop, and installation condition
  5. Confirm route details (shaft, tunnel, corridor, plant room) and whether oversheath is required
  6. Confirm termination kits and accessory system for MI cables
  7. Define length planning to reduce joints on critical routes
  8. Confirm documentation package for inspection and acceptance
FAST RFQ TEMPLATE
Product: YTTW
Voltage grade: __
Standard/criteria: __
Fire-survival requirement (duration/class): __
Core count: __
Cross-sections and quantities: __
Total length (m): __
Installation route: riser / shaft / tunnel / corridor / plant room
Oversheath requirement: yes/no, type: __
Destination: country and port __
Trade term: __
Packing: coil/drum
Preferred lengths: __
Documents required: __
FAQ
Q1 What is YTTW used for
A YTTW is used for emergency and life-safety circuits requiring fire-survival performance, such as fire pumps, smoke control fans, emergency lighting, and critical power routes.
Q2 What is the advantage of mineral insulated construction
A MI construction uses inorganic mineral insulation and a metal sheath, which is selected for maintaining circuit integrity under high heat and fire exposure conditions according to the required acceptance criteria.
Q3 Is YTTW a low-voltage cable
A It is commonly specified for low-voltage systems, often at 0.6/1kV, depending on project requirements.
Q4 Do I need an oversheath
A Many projects specify an oversheath for identification, abrasion protection, and improved handling. The requirement depends on installation route and the governing standard.
Q5 What should I consider for termination
A MI cables typically require compatible termination kits and correct installation practices to maintain insulation integrity and sheath continuity. Confirm the accessory system required in your project.
Q6 What information is needed for accurate quotation
A Voltage grade, fire-survival requirement, core count, cross-sections, total length, route type, oversheath requirement, destination, packing preference, and documentation requirements.
Service of JinHong Company

Over Productions Service: JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

Quality Certification Services: JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

Profession Customer Service: JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

Delivery And Shipping Services: While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.