YJV22 Armored Copper XLPE Cable
,Armored Copper XLPE Cable 0.6/1kV
,Duct Low Voltage Cable
Product Description
The YJV22 is a 0.6/1kV copper-core XLPE insulated, steel-tape armored low-voltage power cable suitable for fixed installations. It is specifically designed for conduits, protected trenches, and utility corridors requiring mechanical protection and stable low-voltage power supply.
The high efficiency of the copper core combined with armor protection makes it suitable for low-voltage lines where damage, delays, or rework are unacceptable.
-
Armor-Prioritized Reliability
The steel-tape armor helps protect the cable from the compressive and external stresses common in underground conduits and construction environments.
-
Copper Core Reliability
Lower conductor resistance contributes to efficient low-voltage power supply and predictable termination performance.
-
XLPE Insulation Stability
XLPE insulation is widely used due to its stable dielectric properties in continuous low-voltage distribution applications.
-
Easy Installation for Installers
Designed for fixed installations in conduits and protected trenches, it is easy to install and ensures line reliability when installed correctly.
-
Procurement Consistency
Universal specifications and core counts help standardize the Bill of Materials (BOQ) and manage phased deliveries.
YJV22 is an armored low-voltage power cable, typically consisting of stranded copper conductors and cross-linked polyethylene (XLPE) insulation, reinforced with padding and steel tape armor, and finally covered with a protective outer sheath (usually PVC, depending on the standard used). It is suitable for stationary installations requiring enhanced mechanical protection.
- Typical Rated Voltage: 0.6/1 kV
- Typical Applications: Low-voltage feeders, branch lines, and distribution lines
- Typical Laying Paths: Underground conduits, protective trenches, basements, utility corridors, protected outdoor feeder sections
- Main feeders from transformers/main distribution boxes to distribution panels
- Conduit-type power distribution in campuses and industrial parks
- Peripheral feeders and road crossings via conduits
- Basement and service tunnel lines subject to higher compression/shock risks
- Industrial facilities where line robustness reduces downtime and maintenance risks
- If low-smoke halogen-free cables are required, select the Low Smoke Halogen-Free (LSZH) model.
- If emergency lines require fire integrity, specify the fire-resistant structure.
- If the line needs to be directly buried, confirm the standards, burial methods, and protection requirements before final installation.
- Conductor: Stranded copper wire
- Insulation: Cross-linked polyethylene (XLPE)
- Inner/Padding Layer: Supports the armor interface and protects the core (depending on standard)
- Armor: Steel tape (22 structure)
- Outer Sheath: Protective sheath (usually PVC, depending on standard)
- Cable Type: Low-voltage armored power cable for fixed installations
-
Copper Stranding
Copper conductors are stranded to achieve resistance control and give them flexibility for easy pulling and wiring.
-
Cross-linked Polyethylene (XLPE) Insulation
The insulation layer is formed using extrusion and cross-linking processes to create a uniform dielectric layer suitable for low-voltage applications.
-
Core
The cores are geometrically controlled stranded to maintain the cable's round shape and allow for smooth passage through conduits.
-
Padding and Armor Layer
A protective padding layer is applied first, followed by a steel tape armor layer wound in a controlled overlap pattern to provide mechanical protection.
-
Sheath and Marking
The outer sheath is manufactured using an extrusion molding process, providing abrasion resistance and environmental protection, and is printed with markings and traceability information.
-
Routine Verification
Typical inspection items include conductor resistance, insulation thickness control, standard-compliant electrical testing, dimensional inspection, and armor/sheath integrity checks.
- 1C, 2C, 3C, 4C, 5C (depending on project)
- 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300
- 4C x 10, 4C x 16, 4C x 25, 4C x 35, 4C x 50, 4C x 70, 4C x 95
- 3C x 10, 3C x 16, 3C x 25, 3C x 35, 3C x 50
- 5C x 10, 5C x 16, 5C x 25, 5 cores x 35
- 1 core x 120, 1 core x 150, 1 core x 185, 1 core x 240
| Model | YJV22 |
|---|---|
| Rated Voltage | 0.6/1 kV |
| Cable Type | Copper core, XLPE insulated, steel tape armored, sheathed low-voltage power cable |
| Conductor | Copper, stranded |
| Insulation | XLPE |
| Armor | Steel tape (22-layer structure) |
| Outer Sheath | Protective sheath (usually PVC, depending on standard) |
| Core Options | 1 core/2 cores/3 cores/4 cores/5 cores |
| Size Range | 2.5 to 300 mm² (depending on core count and applicable standard) |
| Installation Methods | Fixed installation in conduits, protective trenches, utility corridors, protective outdoor lines |
| Typical Applications | Underground low-voltage feeder distribution circuits |
| Packaging | Export drum packaging is recommended for armored specifications; small-size coils are available upon agreement. |
| Options | Sheath color, marking language, reel length scheme, packaging marking, documentation kit, inspection support |
- Confirmation of Standards/Acceptance Standards and Voltage Rating (typical values are...) 0.6/1kV
- Confirm cabling type (cable trench, protective trench, corridor) and mechanical risks
- Select conductor quantity based on system design and neutral/protective conductor scheme
- Determine dimensions based on current carrying capacity and voltage drop (distance, grouping, environmental/soil conditions, installation method)
- Determine reel length strategy to reduce joints in underground cabling
- Confirm termination method, terminal blocks, and installation procedure for armored copper cable
| Product | YJV22 |
|---|---|
| Voltage | 0.6/1 kV |
| Standard/Requirement | __ |
| Number of conductors | __ |
| Cross-section and quantity | __ |
| Total length (meters) | __ |
| Cabling method | Cable trench/Protective trench/Corridor/Protective outdoor |
| Destination country and port | __ |
| Trade terms | __ |
| Packaging | Reel |
| Preferred reel length | __ |
| Required documents | __ |
| Special requirements | Marking language/Sheath color/Inspection/Delivery schedule |
A: YJV22 is used for fixed-installation low-voltage feeders and distribution lines requiring steel-belt armor, especially suitable for underground pipelines, protective trenches, and utility corridors.
A: It usually indicates a steel-belt armored structure to enhance the mechanical protection against pressure and external stress in fixed installation paths.
A: YJV is usually used for protective paths and is not armored. YJV22 adds steel-belt armor and is suitable for environments with high mechanical risks, such as pipelines and trenches.
A: Yes, it is commonly used for underground pipelines and protective trenches. Please confirm the installation method and acceptance testing according to the project standards.
A: It is commonly used for pipelines and protective trenches. If direct burial is required, please confirm the standard requirements, burial depth, backfill soil, and additional protective measures before selection.
A. Standards/guidelines, core sample quantity, specification list, total meters, line type, destination, reel length requirements, and documentation requirements.
-
Over Productions Service:
JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.
-
Quality Certification Services:
JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.
-
Profession Customer Service:
JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.
-
Delivery And Shipping Services:
While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.
JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.