| Brand Name: | Jinhong |
| Model Number: | YJV22 |
| MOQ: | 100m |
| Price: | 5.15-25USD/m |
| Payment Terms: | T/T |
YJV22 is a 0.6/1kV copper core, XLPE insulated, steel tape armored, PVC sheathed power cable suitable for fixed installations. It is ideal for underground conduits, protective trenches, and utility corridors, providing enhanced mechanical protection and stable low-voltage performance.
When your lines require more protection than the basic sheath, choose YJV22. This armored low-voltage power cable is designed to withstand installation stresses, effectively preventing compression and maintaining stable feeder performance in underground and conduit environments where reliability is critical.
YJV22 is a widely used armored low-voltage power cable for fixed installations. It typically uses stranded copper core conductors for efficient power transmission, an XLPE insulation layer for strong dielectric properties, an inner liner to support the armor interface, steel tape armor for mechanical protection, and a PVC outer sheath to enhance its abrasion and environmental resistance in common installation environments. YJV22 cables are commonly used in underground cable trenches, protective trenches, and equipment access areas, where unarmored cables may be subject to higher compressive forces, construction loads, or impact risks.
Not suitable for dragging, coiling, or repeated moving
Size Selection
Select the cross-sectional area based on current, distance, permissible voltage drop, grouping, environmental or soil conditions, and installation method. Voltage drop control is typically a priority for long feeders.
Termination and Connections
Use certified terminals and the correct crimping tools, applying controlled torque. Plan the drum length to minimize field joints, especially in underground wiring.
Line Design
If direct burial is required, confirm relevant standards and specify appropriate construction and burial protection methods.
Copper Stranded Wire and Resistance Control
Conductor stranding is controlled to ensure stable resistance and facilitate installation.
XLPE Insulation Molding
Extrusion and cross-linking processes are used to form a uniform dielectric layer suitable for low-voltage applications.
Core Assembly and Geometry Control
Core wires are stranded to maintain roundness and improve conduit insertion performance.
Protective Layer and Armor Structure
The protective layer protects the insulated core wires; the steel tape armor layer is wound in a controlled overlap manner to provide mechanical protection.
Sheath and Marking
A polyvinyl chloride (PVC) sheath is used to enhance abrasion resistance and protection, and features clear markings for easy traceability.
Routine Inspections
Typical inspection items include conductor resistance, insulation thickness, spark/voltage testing according to standards, dimensional inspection, and sheath/armor integrity checks.
| Model | YJV22 |
|---|---|
| Cable Type | Copper core XLPE insulated steel tape armored PVC sheathed low-voltage power cable |
| Rated Voltage | 0.6/1 kV |
| Conductor | Copper, stranded |
| Insulation | XLPE |
| Armor | Steel tape (Type 22) |
| Outer Sheath | PVC (depending on standard) |
| Number of Cores Options | 1 core/2 cores/3 cores/4 cores/5 cores |
| Typical Size Range | 2.5 to 300 mm² (depending on core count and standard) |
| Typical Applications | Underground low-voltage feeders, conduits, protective trenches, utility corridors |
| Installation Method | Fixed installation |
| Packaging | Export reels are recommended for armored cables; coil packaging is available for small-size cables upon request. |
| Customization | Sheath color, marking language, reel length options, packaging markings, document package, inspection support |
Q1 What is YJV22 mainly used for?
A. It is a low-voltage feeder used for fixed installations, suitable for underground conduits, protected trenches, and laying routes with high mechanical risks requiring steel-tape armor.
Q2. What does the "22" in YJV22 mean?
A. It usually indicates a steel-tape armored structure to enhance mechanical protection against compression and external stresses.
Q3. What is the difference between YJV22 and YJV?
A. YJV is usually unarmored and used for indoor protection of wiring; while YJV22 uses steel-tape armor and is suitable for underground and high-stress installation environments.
Q4. Is YJV22 suitable for direct burial?
A. It is usually used for conduits and protected trenches. If direct burial is required, please confirm the project standards, burial method, and protection requirements.
Q5. What is the common core wire configuration for three-phase power distribution?
Three-phase plus neutral wire typically uses 4 cores. When a dedicated PE conductor is required, 5 cores are used. The final selection depends on design specifications and local regulations.
Q6. What details help in providing an accurate quote?
A. Required standards, core quantity, specification list, total meters, line type, destination, reel length requirements, and documentation requirements.
Over Productions Service:
JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.
Quality Certification Services:
JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.
Profession Customer Service:
JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.
Delivery And Shipping Services:
While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.
Packaging of JinHong:
JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.