products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Low Voltage Cable
Created with Pixso.

1 To 5 Cores Armored Aluminum XLPE Cable 0.6/1kV To 33kV Multicore Cable

1 To 5 Cores Armored Aluminum XLPE Cable 0.6/1kV To 33kV Multicore Cable

Brand Name: JinHong
Model Number: YJLV22
MOQ: 100m
Price: 6.55-18USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Insulationmaterial:
PVC, XLPE, Or Rubber
Voltagerating:
Up To 35kV
Productname:
Industrial Power Cables
Maximumoperatingvoltage:
0.6/1kV To 33kV
Waterresistance:
Yes, Suitable For Underground And Underwater Use
Cabletype:
Single Core Or Multi-core
Application:
Power Distribution In Industrial Environments
Conductormaterial:
Copper Or Aluminum
Temperaturerange:
-40°C To 90°C
Standardscompliance:
IEC, BS, UL, Or IEEE
Flameretardant:
Yes
Sheathmaterial:
PVC Or PE
Armortype:
Steel Wire Armor (SWA) Or Aluminum Wire Armor (AWA)
Numberofcores:
1 To 5 Cores
Highlight:

Armored Aluminum XLPE Cable

,

5 Cores Aluminum XLPE Cable

,

33kV Multicore Cable

Product Description

YJLV22 is a 0.6/1kV aluminum core XLPE insulated steel tape armored low-voltage power cable suitable for fixed installations. It is specifically designed for locations requiring mechanical protection and cost-effective wiring, such as conduits, protected trenches, and utility corridors.

Product Highlights

YJLV22 is a practical underground feeder cable suitable for large projects. It combines the advantages of an aluminum core with V22 steel tape armor protection, helping you control costs, reduce weight, and improve the reliability of lines installed in conduits and trenches.

Product Overview

YJLV22 is an armored low-voltage distribution cable typically featuring a stranded aluminum core and XLPE insulation, reinforced with a padding layer and steel tape armor, and finally coated with a protective outer sheath. It is suitable for fixed installations where the cable may be subject to compression risks, construction loads, or high installation stresses, such as underground conduits, protected trenches, basements, and utility corridors. This cable model is widely used in rice cable bills of quantities (BOQs) due to its aluminum conductor, which improves project cost-effectiveness and reduces cable weight for easier installation. Furthermore, the V22 armored design provides superior line protection compared to unarmored aluminum feeder cables.

Low Voltage Ratings

Typical Rated Voltage: 0.6/1 kV

Typical Applications: Fixed low-voltage feeder and distribution lines

Project Notes: Please confirm the standards, sheath material requirements, and installation conditions in your BOQ.

YJLV22 Application Areas
Core Applications
  • Main feeders for residential buildings, commercial buildings, and industrial facilities
  • Underground conduit and protective trench wiring
  • Perimeter power distribution and indoor/outdoor transitions
  • Basement service corridors and equipment room access routes
  • Low-voltage distribution networks in industrial parks and campuses
Typical Installation Paths
  • Underground conduit and ductwork
  • Protective trenches with proper backfilling
  • Utility corridors and fixed protective outdoor wiring
  • Not suitable for dragging, coiling, or continuous movement
Reasons Buyers Choose YJLV22
  • Economic Benefits for Long-Distance Lines

    Aluminum conductors reduce material costs and overall cable weight, improving logistics and installation efficiency for high-volume feeders.

  • V22 Armor Provides Enhanced Mechanical Protection

    Steel tape armor helps resist compressive and external mechanical stresses common in underground and built environments.

  • XLPE Insulation Ensures Stable Low-Voltage Circuit Operation

    XLPE insulation provides reliable dielectric strength and continuous operational reliability for low-voltage feeder circuits.

  • Easy for construction workers to use

    Common specifications and export drum packaging facilitate repeat orders, phased delivery, and help speed up installation plans.

Engineering Considerations for Procurement
  • Cross-section Selection

    Aluminum typically requires a larger conductor cross-section than copper to achieve similar voltage drop and current capacity. Size selection should be calculated based on load, distance, grouping, and the thermal conditions of the soil or piping.

  • Termination Specifications

    Use aluminum terminal blocks or bimetallic terminal blocks where necessary, and follow the installation procedure using the correct crimping die, controlling torque, and applying antioxidants. Clean termination specifications are a key factor in ensuring long-term performance.

  • Joint Planning

    Determine reel length and joint locations early to reduce the number of joints in the field and speed up commissioning.

Typical Structure Overview
Conductor:
Aluminum stranded wire
Insulation:
Cross-linked polyethylene (XLPE)
Inner Liner/Padding:
Armored interface protective padding (depending on standard)
Armor:
Steel tape (V22 type)
Outer Sheath:
Protective sheath (usually PVC, depending on standard)
Cable Type:
Armored low-voltage power cable for fixed installation
Process and Manufacturing Notes
  • Aluminum Conductor Stranding

    Stretching method is strictly controlled to ensure consistent resistance and improve operability during installation.

  • Cross-linked Polyethylene (XLPE) Insulation Extrusion and Cross-linking

    Insulation layer molding ensures excellent low-voltage dielectric properties and stable service life.

  • Core Structure and Geometry Control

    Stable roundness is maintained during core assembly, thereby improving traction performance in conduits.

  • Padding Coating and Steel Tape Armoring

    Padding protects the insulated cores, followed by armor coating with controlled overlap to improve mechanical protection.

  • Outer Sheath Extrusion Molding and Marking

    The sheath provides abrasion resistance and environmental protection, and features clear markings for traceability.

  • Routine Inspections

    Typical inspections include conductor resistance, insulation thickness, spark/voltage testing, dimensional inspection, and armor/sheath integrity verification.

General Specifications Overview
Common Core Wire Configurations (Depending on Project)
  • 1C for Single-Core Feeders
  • 2C for Single-Phase Circuits
  • 3C for Three-Phase Circuits Without Neutral (Depending on Design)
  • 4C for Three-Phase Feeders with Neutral (Common)
  • 5C for Three-Phase Feeders with Neutral and Protection Circuits (Depending on Design)
Common Cross-Sectional Areas (mm²)

16 25 35 50 70 95 120 150 185 240 300 400 500

Common Configurations
  • 4C x 25 4C x 35 4C x 50 4C x 70 4C x 95 4C x 120
  • 3C x 35 3C x 50 3C x 70 3C x 95 3C x 120
  • 1C x 150 1C x 185 1 core x 240 1 core x 300
  • 5 cores x 25 5 cores x 35 5 cores x 50 5 cores x 70
Specifications (can be copied directly)
Model:
YJLV22
Cable Type:
Aluminum core, cross-linked polyethylene (XLPE) insulated, V22 steel tape armored low-voltage power cable
Rated Voltage:
0.6/1 kV
Conductor:
Aluminum stranded wire
Insulation:
Cross-linked polyethylene (XLPE)
Armor:
Steel tape (V22)
Outer Sheath:
Protective sheath (usually PVC, depending on standard)
Core Wire Specifications:
1 core, 2 cores, 3 cores, 4 cores, 5 cores
Common Specifications:
16 to 500 mm² (Specific specifications depend on the order)
Typical Installations:
Conduit, Protective Trench, Utility Corridor, Protected Outdoor Lines
Typical Applications:
Building Main Feeders, Industrial and Park Power Distribution, Underground Low-Voltage Lines
Packaging:
Export packaging recommended for armored feeder sizes.
Customization Options:
Core Marking, Sheath Color, Marking Language, Reel Length Options, Packaging Marking, Documentation Kit, Inspection Support
Quick Selection Guide
  1. Confirm 0.6/1kV Voltage Rating and Relevant Standards
  2. Confirm Line Type and Mechanical Protection Requirements (Why a V22 Reel is Needed)
  3. Select the Number of Cores Based on System Design and Neutral/Sheath Requirements
  4. Select the Cross-Sectional Area Based on Current Carrying Capacity, Distance, Grouping Method, and Voltage Drop Limitations
  5. Confirm the Terminal Accessories and Installation Procedures for Aluminum Conductors
  6. Determine the Reel Length and Connector Options to Reduce Risks in Underground Lines
Quick Inquiry Template
Product:
YJLV22
Voltage:
0.6/1kV kV
Required Standard:
__
Core Configuration:
__
Cross-sectional Area and Quantity:
__
Total Length:
__ meters
Line Type:
Conduit/Protective Trench/Utility Corridor/Protective Outdoor Line
Destination:
Country and Port __
Trade Terms:
Packaging: Drum
Recommended Drum Length:
__
Required Documents:
__
Remarks:
Marking Language, Inspection Requirements, Delivery Schedule
Frequently Asked Questions

Q1 What is YJLV22 mainly used for?

A It is used for low-voltage fixed installation feeders requiring V22 steel-tape armored mechanical protection, such as in underground pipelines, protective trenches, and utility corridors.

Q2 What does V22 mean?

A V22 generally indicates a steel-tape armored structure, designed to improve compressive strength and resistance to external mechanical stresses in fixed installation routes.

Q3 How is YJLV22 different from YJLV?

A YJLV is typically an unarmored aluminum-clad cross-linked polyethylene (XLPE) feeder cable, while YJLV22 adds steel-tape armor to better handle underground and mechanically hazardous routes.

Q4 Do aluminum feeders require larger dimensions than copper feeders?

A Generally yes. Aluminum typically requires a larger cross-sectional area to match copper wire in terms of voltage drop and current carrying capacity. The final selection must be calculated based on your design.

Q5 Is YJLV22 suitable for direct burial?

A. It is typically used for pipelines and protective trenches. For direct burial, please confirm the route conditions and develop a construction plan according to project standards.

Q6. What information is needed for a quick quote?

A. Required information includes: standards, number of core samples, cross-section, total length (meters), route type, destination, core tube length requirements, and required documents.

Service of JinHong Company
Over Productions Service:
JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.
Quality Certification Services:
JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.
Profession Customer Service:
JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.
Delivery And Shipping Services:
While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.
Packaging of JinHong:
JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.