products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Low Voltage Cable
Created with Pixso.

0.6/1kV LV Power Cable WDZ-KYJYRP LSZH Shielded XLPE Control Cable

0.6/1kV LV Power Cable WDZ-KYJYRP LSZH Shielded XLPE Control Cable

Brand Name: JinHong
Model Number: WDZ-KYJYRP
MOQ: 100m
Price: 9.15-23 USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Gases Corrosivity:
IEC 60754
Sheath:
PVC
Type:
Coaxial
Approval:
CE|RoHS|FCC|UL|SAA
Outer Sheath:
UV Ray Resistant PVC
Amour:
Steel Tape
Direct Burial:
Yes
Insulation:
XLPE 2XI1
Insulation Material:
XLPE
Conductormaterial:
Copper Or Aluminum
Fire Resistance:
Yes
Colour:
Customize
Shielding:
Available/Not Available
Input Frequency:
47~63Hz
Installation Type:
Surface Mount
Highlight:

0.6/1kV LV Power Cable

,

LV Power Cable WDZ-KYJYRP

,

LSZH Shielded XLPE Control Cable

Product Description
WDZ-KYJYRP LSZH Shielded XLPE Control Cable 0.6/1kV for Automation
WDZ-KYJYRP

WDZ-KYJYRP is a low-smoke halogen-free shielded XLPE control cable suitable for 0.6/1kV low-voltage control and monitoring circuits. It is designed for electromagnetic compatibility (EMC) protection, safer indoor wiring, and stable automation wiring in buildings, tunnels, and industrial plants.

Value Statement

WDZ-KYJYRP is ideal when your control circuits require higher voltage ratings, low-smoke halogen-free (LSZH) safety, and shielding to reduce interference in complex electrical environments.

Product Overview

WDZ-KYJYRP is a shielded control cable typically featuring stranded copper conductors, XLPE insulation, an overall shielding layer for reducing electromagnetic interference, and a low-smoke halogen-free (LSZH) outer sheath. Compared to standard control cables, this model is designed to achieve three procurement objectives: ensuring safer wiring in enclosed or high-density spaces through low-smoke halogen-free (LSZH) materials; improving signal quality stability through shielding; and expanding application range through a higher low-voltage rating (typically 0.6/1kV). It is widely used in automation control panels, MCC and switchgear control circuits, instrumentation circuits, HVAC systems, transportation infrastructure equipment rooms, and high-density cable trays where project specifications include EMC control and safety clauses.

Low-Voltage Ratings

Typical Rated Voltage: 0.6/1 kV

Applications: Fixed-installation control, monitoring, interlocking, and instrumentation circuits

Note: Please confirm the specific standards, shielding requirements, and acceptance tests specified in your Bill of Materials (BOQ).

Applications of WDZ-KYJYRP
Common Applications
  • PLC and DCS I/O cabling in industrial automation
  • Switchgear, MCC, and switchboard control circuits
  • Instrumentation and monitoring circuits in noisy electrical environments
  • HVAC and building management system cabling in large facilities
  • Stations, tunnels, and transportation hubs requiring Low Smoke Halogen-Free (LSZH) cables
  • Data centers, equipment rooms, and dense cable trays requiring higher electromagnetic compatibility (EMC) performance
Typical Installation Routes
  • Cable trays, conduits, cable trays, shafts, corridors, and protected fixed routes
  • Not suitable for continuous dragging, heavy-duty pulling, or violent high-frequency movement
Why Buyers Choose WDZ-KYJYRP
  • Low Smoke Halogen-Free (LSZH) cables ensure safer evacuation and lower corrosion risk

    Low Smoke Halogen-Free (LSZH) sheathed systems are used to reduce smoke in confined space fires and prevent the generation of corrosive halogen gases.

  • Shielding provides clearer control signals

    Complete shielding helps reduce electromagnetic interference and improves signal stability near inverters, motors, switchgear, and high-density cable installations.

  • XLPE insulation ensures stable low-voltage operation

    XLPE insulation provides stable dielectric properties and thermal stability for control circuits under continuous operating conditions.

  • Higher voltage ratings, wider coverage

    When control cables share a laying path with power feeders, or when project specifications require higher insulation performance, cables with a 0.6/1kV voltage rating are typically required.

Structural Overview
Conductor:
Copper stranded wire
Insulation:
Cross-linked polyethylene (XLPE)
Core Identification:
Numbered or color-coded (as required)
Shielding:
Integral shielding to reduce electromagnetic interference (EMI) (braided layer and/or tape, depending on specifications)
Outer Sheath:
Low smoke halogen-free (LSZH)
Cable Type:
Multi-core shielded control cable for fixed installations
Process and Manufacturing Notes
  • Conductor Stranding and Resistance Stability

    The stranding design balances flexibility and consistent resistance, ensuring reliable performance of the control circuitry.

  • Cross-linked polyethylene (XLPE) Insulation Extrusion and Cross-linking

    The molding of the insulation layer ensures reliable dielectric properties and long-term stability.

  • Core Routing and Geometric Control

    The assembly of the cores ensures stable cable roundness, thereby improving pulling performance in conduits and cable trays.

  • Shielding Application and Continuity Control

    The shielding coating employs controlled coverage to meet electromagnetic compatibility (EMC) targets and shielding continuity requirements.

  • Low-Smoke Halogen-Free Sheath and Marking

    The low-smoke halogen-free sheath is manufactured using an extrusion molding process to protect the internal structure and meet safety requirements. It is then marked for easy traceability.

Routine Inspections

Typical inspections include conductor resistance, insulation thickness, spark testing, voltage testing, dimensional inspection, sheath integrity, and shielding continuity checks (all performed according to standards).

Common Specifications Overview
Common Core Counts in Automation Projects

2 to 61 cores (depending on order)

Common Conductor Cross-sectional Areas (mm²) for Control and Monitoring

0.5 0.75 1.0 1.5 2.5 4 6 10

Quick Deployment Configurations
  • 4 cores x 1.5
  • 6 cores x 1.5
  • 8 cores x 1.5
  • 10 cores x 1.5
  • 12 cores x 1.5
  • 16 cores x 1.5
  • 20 cores x 1.5
  • 24 cores x 1.5
  • 30 cores x 1.5
  • 4 cores x 2.5
  • 12 cores x 2.5
  • 24 cores x 2.5
  • 7 cores x 1.5
  • 19 cores x 1.5
Specifications (can be copied directly)
Property Value
Model WDZ-KYJYRP
Cable Category Low Smoke Halogen-Free Shielded Cable, Control Cable
Typical Rated Voltage 0.6/1 kV
Conductor Copper Stranded Wire
Insulation Cross-linked Polyethylene (XLPE)
Shielding Integral Shielding Structure (by specification)
Outer Sheath Low Smoke Halogen-Free (LSZH)
Number of Cores 2 to 61 cores (common range, depending on order quantity)
Conductor Size 0.5 to 10 mm² (common range, depending on order quantity)
Typical Operating Temperature XLPE insulation design up to 90°C (depending on standard)
Installation Method Fixed installation in cable trays, conduits, cable trays, shafts, corridors, tunnels
Packaging Small sizes are packaged in rolls; export-grade cable reels suitable for large projects
Customization Services Core wire numbering, sheath color, marking language, reel length options, documentation sets, inspection support
Selection Guide
  1. Please refer to your Bill of Materials (BOQ) Confirm the required standards and voltage rating (typically 0.6/1kV)
  2. Define shielding requirements: braided layer, tape, overall shielding coverage, and continuity targets
  3. Select the number of cores and cross-sectional area based on controlled load, loop length, and voltage drop limitations
  4. Confirm the installation route, grouping density, and ambient temperature
  5. Confirm Low Smoke Halogen-Free (LSZH) requirements for enclosed spaces and public routes
  6. Specify armored LSZH shielded cables if there are mechanical risks or underground compression issues with the route.
Quick Inquiry Template
Product:
WDZ-KYJYRP
Voltage Rating:
0.6/1 kV
Required Standards:
__
Shielding Requirements:
Braided Layer/Tape/Overall Shielding/Coverage __
Number and Size of Cores:
__ cores x __ mm²
Total Length:
__ meters
Installation Path:
Tray/Conduit/Cable Trunking/Shaft/Corridor/Tunnel
Destination:
Country and Port__
Trade Terms:
__
Packaging:
Roll/Reel
Preferred Reel Length:
__
Required Documents:
__
Remarks:
Markup Language, Delivery Schedule, Inspection Requirements
Frequently Asked Questions
  • Q1 What is WDZ-KYJYRP mainly used for?

    A It is used in low-voltage control and monitoring circuits where low-smoke halogen-free (LSZH) safety and shielding are required to reduce interference and improve signal stability in fixed installations.

  • Q2 Why choose 0.6/1kV class control cables?

    A Some projects require control cables laid along power feeders to use higher insulation classes, or to meet more stringent insulation requirements in the Bill of Quantities (BOQ).

  • Q3 What is the function of the shielding layer?

    A The shielding layer helps reduce electromagnetic interference from drives, motors, switchgear, and dense cable runs, thereby improving the reliability of control signals.

  • Q4 What is the most commonly used wire diameter?

    A: The most commonly used wire diameter for control cabling is 0.5 to 2.5 mm². Larger wire diameter cables are used for higher control power or longer loops.

  • Q5 Can this type of cable be used in tunnels and public buildings?

    A: Yes. Low smoke halogen-free (LSZH) cable is often specified for enclosed or densely populated areas where it is required, provided the project standards meet the required performance requirements.

  • Q6 What information helps expedite a quote?

    A: Standards, shielding requirements, number of conductors, cross-sectional area list, total length (meters), installation route, destination, packaging method, and documentation requirements.

Service of JinHong Company
  • Over Productions Service:

    JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

  • Quality Certification Services:

    JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

  • Profession Customer Service:

    JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

  • Delivery And Shipping Services:

    While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.