products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Low Voltage Cable
Created with Pixso.

NH-YJV Fire-Resistant XLPE Cable 0.6/1kV for Emergency Power

NH-YJV Fire-Resistant XLPE Cable 0.6/1kV for Emergency Power

Brand Name: JinHong
Model Number: NH-YJV
MOQ: 100m
Price: 7.15-15USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Waterresistance:
Waterproof Or Water-resistant Options
Numberofcores:
1, 2, 3, Or More
Mechanicalprotection:
Steel Wire Armor Or Tape Armor
Application:
Power Distribution In Industrial Plants, Factories, And Infrastructure
Standardscompliance:
IEC, BS, UL, IEEE
Productname:
Industrial Power Cables
Insulationmaterial:
PVC, XLPE, Or Rubber
Temperaturerange:
-40°C To +90°C
Cabletype:
Armored Or Unarmored
Sheathmaterial:
PVC, PE, Or LSZH
Voltagerating:
0.6/1kV, 3.6/6kV, 6/10kV, Up To 35kV
Flameretardant:
Yes, Available
Conductormaterial:
Copper Or Aluminum
Currentcapacity:
Depends On Cable Size And Installation Conditions
Installationmethod:
Underground, Overhead, Or Direct Burial
Highlight:

0.6/1kv low voltage cable

,

35kv low voltage cable

Product Description

NH-YJV is designed for one task: maintaining power to critical low-voltage circuits during a fire. When your Bill of Quantities (BOQ) requires fire-resistant cable, circuit integrity cable, or emergency power continuity cable, NH-YJV provides a practical and immediately deployable solution to support life-saving systems without requiring entirely different wiring methods.

Product Overview

NH-YJV is a fire-resistant low-voltage power cable, typically featuring stranded copper conductors and cross-linked polyethylene (XLPE) insulation, combined with a fire-resistant design to maintain electrical continuity under fire test conditions (test category and duration depend on specific standards). It is commonly used in public buildings, industrial facilities, transportation hubs, and high-density residential projects for emergency feeders and critical services, where continuous power supply to safety equipment must be ensured during evacuation and firefighting operations.

Low-Voltage Ratings

Typical Rated Voltage: 0.6/1 kV

Typical Application: Fixed low-voltage distribution for critical circuits

Note: Fire resistance performance must be fully consistent with the test methods, durations, and categories specified in the project specifications.

Applications of NH-YJV

Common Applications

  • Emergency lighting and exit sign power supply
  • Fire alarm system power supply and critical control power supply
  • Fire pumps, sprinkler controllers, and emergency water supply equipment
  • Smoke exhaust systems, booster fans, and fire dampers
  • Elevator emergency circuits and critical building equipment
  • Critical industrial circuits for emergency shutdown and safe loads

Common Installation Routes

  • Risers, shafts, corridors, equipment rooms, protective trays, conduits, and designated emergency routes
  • Fixed installation only

Reasons Buyers Choose NH-YJV

Fire resistance for critical loads

NH-YJV is chosen to maintain circuit integrity during a fire, ensuring emergency systems can continue to operate when needed.

XLPE insulation ensures stable low-voltage performance

XLPE insulation ensures stable electrical performance and is the material of choice for low-voltage feeders carrying continuous loads.

Clear compliance objectives support tendering projects

NH-YJV standards are often included in the Bill of Quantities (BOQ) for life safety and utility works, helping procurement teams meet inspection requirements.

Convenient sourcing and repeat orders

Universal sizes, standardized construction, and export packaging options support phased delivery for EPC and contractors.

Common Specifications Overview

Common Core Wire Configurations (Depending on Project)

  • 1C Dedicated Emergency Feeder and Single-Core Cabling
  • 2C Single-Phase Emergency Circuit
  • 3C Three-Phase Circuit Without Neutral (Depending on Design)
  • 4C Three-Phase with Neutral
  • 5C Three-Phase with Neutral and Emergency Power Supply (Depending on Design)

Depending on local design specifications, some bills of quantities may include 3+1 and 3+2 configurations.

Common Cross-Sectional Areas (mm²)

1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

High-Frequency Ordering Combinations (Examples)

  • 2C x 1.5 2C x 2.5 2C x 4
  • 3C x 2.5 3C x 4 3C x 6
  • 4C x 10 4C x 16 4C x 25 4C x 35
  • 1C x 70 1C x 95 1C x 120 1C x 150

Structure Overview

  • Conductor: Copper stranded wire
  • Insulation: Cross-linked polyethylene (XLPE)
  • Fire-resistant design: Fire-resistant components conforming to relevant standards and test categories
  • Outer sheath: Protective sheath system (subject to project requirements)
  • Application: Fixed installation for emergency and critical circuits

Manufacturing and Process Description

Conductor stranding and resistance control

The copper stranded wire is manufactured to meet stable resistance targets to ensure consistent performance and reliable termination.

Cross-linked polyethylene (XLPE) insulation extrusion and cross-linking

The insulation layer is extruded and cross-linked to form a durable dielectric layer suitable for low-voltage distribution.

Fire-resistant structural integration

Dedicated fire-resistant structural components are used to ensure circuit continuity under the fire-resistant testing conditions specified in the project standards.

Sheath and surface treatment

The outer sheath provides mechanical protection and identification markings, supporting traceability of project delivery.

Routine Production Inspections

  • Typical inspections include conductor resistance, insulation thickness, spark testing, voltage testing, dimensional verification, and sheath integrity checks.

Specifications

Model NH-YJV
Cable Type Fire-resistant XLPE insulated copper low-voltage power cable
Rated Voltage 0.6/1 kV
Conductor Material Copper
Conductor Type Stranded
Insulation Material XLPE
Fire Resistance Circuit integrity under fire testing (duration/category as specified)
Sheath Protective outer sheath (depending on project requirements)
Core Options 1 core, 2 cores, 3 cores, 4 cores, 5 cores, 3+1 cores, 3+2 cores (as required)
Common Size Range 1.5 to 300 mm²
Typical Continuous Operating Temperature Up to 90°C with XLPE insulation design (depending on standards)
Typical Installation Methods Conduit, cable tray, riser, shaft, emergency circuit protection
Packaging Small sizes are packaged in rolls; large sizes are packaged in export reels (depending on project)
Optional Configurations Custom markings, reel length diagram, packaging markings, document suite, third-party inspection support

How to Choose the Right Cable for Your Bill of Quantities NH-YJV

  1. Confirm the required fire resistance test method, duration, and category for the project.
  2. Confirm whether Low Smoke Halogen-Free (LSZH) testing is required; if so, specify the use of an LSZH fire-resistant structure instead of a standard sheath.
  3. Select the number of conductors based on the circuit design (single-phase, three-phase, neutral/protection circuit requirements).
  4. Determine the conductor size based on current, path length, ambient temperature, grouping method, and allowable voltage drop.
  5. Provide recommended reel lengths to reduce joints and speed up installation.

Quick Inquiry Template

Product NH-YJV
Voltage 0.6/1 kV
Fire Resistance Requirements (Test Category and Duration) __
Required Standards __
Core Wire Configuration __
Cross-section and Quantity __
Total Length __ meters
Installation Path Tray/Conduit/Riser/Shaft/Protective Path
Destination Country and Port: __
Trade Terms __
Packaging Roll/Cylinder
Required Documents __
Special Notes Marking Language, Delivery Schedule, Inspection Requirements

Frequently Asked Questions

Question 1: What is NH-YJV?

Q2 What does NH-YJV refer to?

A It generally refers to a fire-resistant copper core power cable with cross-linked polyethylene (XLPE) insulation, designed to maintain circuit integrity under specific fire resistance test conditions.

Q2 Is NH-YJV the same as flame-retardant cable?

A No. Flame-retardant cables primarily focus on limiting the spread of flames; fire-resistant cables focus on maintaining normal circuit operation during a fire. NH indicates fire resistance requirements.

Q3 What voltage rating is NH-YJV used for?

A It is typically used as a 0.6/1 kV low-voltage cable for fixed-installation emergency circuits and critical feeders.

Q4 Which systems most commonly specify NH-YJV?

A Emergency lighting, fire alarm power supplies, smoke exhaust fans, fire pumps, evacuation systems, and other critical equipment that must maintain power during a fire.

Q5 What are the commonly used specifications in emergency projects?

A Emergency lighting and control power supplies typically use smaller specifications (1.5 to 10 mm²). Depending on the load and distance, medium to large (16 to 120 mm² and above) cables are suitable for fire pump and safety equipment power supply.

Q6 What information is needed for a quick quote?

A Required standards, fire resistance time/rating, core material configuration, size list, total length (meters), installation route, destination, and packaging requirements.

Service of JinHong Company

Over Productions Service:

JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

Quality Certification Services:

JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

Profession Customer Service:

JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

Delivery And Shipping Services:

While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.