Underground And Ducts Outdoor Low Voltage Cable 0.6/1kV 3.6/6kV
Product Summary
Product Details
Ducts Outdoor Low Voltage Cable
,Outdoor Low Voltage Cable 0.6/1kV
,3.6/6kV Low Voltage Cable
Product Description
WDZ-YJY23 LSZH XLPE Armored Cable 0.6/1kV for Underground and Ducts
WDZ-YJY23 is a low-smoke halogen-free (LSZH) XLPE insulated copper core power cable with steel tape armor, suitable for 0.6/1kV systems. It is specifically designed for fixed installation environments such as conduits, trenches, and underground lines requiring LSZH safety and mechanical protection.
WDZ-YJY23 is ideal when your project requires LSZH low-smoke performance and additional armor protection for low-voltage cable lines underground or with high mechanical risks.
WDZ-YJY23 is a low-voltage copper core power cable typically featuring XLPE insulation, an LSZH outer sheath system, and steel tape armor. Product models are identified with "23". It is commonly used for fixed installations with high mechanical risks, such as underground conduits, trenches, utility corridors, and protected outdoor lines. Compared to unarmored low-smoke halogen-free cross-linked polyethylene (XLPE) power cables, WDZ-YJY23 cables have an additional mechanical protective layer, resisting compression and external impacts while meeting low-smoke halogen-free requirements. This helps reduce smoke and corrosive halogen gases generated in fires in confined spaces and public areas.
Typical Rated Voltage: 0.6/1 kV
Applications: Low voltage feeders, underground power distribution, and protected outdoor fixed installations
- Underground conduit and trench installations for low voltage power distribution
- Utility corridors, basements, and protected outdoor wiring
- Industrial parks and commercial facilities with long feeder lines
- Public infrastructure with Low Smoke Halogen-Free (LSZH) requirements in enclosed corridors
- Cable lines exposed to compression risks or occasional external shocks
- Feeder connections between substations, switchboards, and building distribution systems
- Underground conduits, protected trenches, utility passageways, and fixed outdoor wiring
- Cable trays and risers requiring additional mechanical protection
LSZH sheathing systems are designed to provide support by reducing smoke during fires and preventing the generation of corrosive halogen gases. Safer evacuation visibility and reduced risk of equipment corrosion.
The 23-layer armored construction enhances protection against compressive and external mechanical stresses in underground and high-risk lines.
XLPE insulation provides reliable dielectric properties and thermal stability for continuous load low-voltage distribution.
In complex and high-risk situations, bills of quantities often specify armored low-smoke halogen-free cables for a more robust structure.
- Conductor:
- Copper stranded wire
- Insulation:
- Cross-linked polyethylene (XLPE)
- Inner Liner:
- Armored interface protection layer (depending on standard)
- Armor:
- Steel tape armor (Type 23, depending on standard)
- Outer Sheath:
- Low smoke halogen-free (LSZH)
- Installation Methods:
- Fixed installation, underground conduit, trench, and protection line
- Copper Conductor Stranding and Resistance Control
- Conductor resistance is stabilized during production to ensure performance of long-distance low-voltage feeders.
- Cross-linked Polyethylene (XLPE) Insulation Extrusion and Cross-linking
- The insulation layer formation ensures excellent dielectric properties and long-term stability.
- Core Identification and Wiring
- Cores are assembled using geometric control to improve roundness and reduce tensile friction within the conduit.
- Rack Application
- Racks are used to enhance armor fit and protect the insulated cores.
- Steel Tape Armor
- Steel tape armor uses controlled overlap and tension to provide mechanical protection against external forces. Low-Smoke Halogen-Free Sheath and Labeling
- Low-Smoke Halogen-Free Sheath and Labeling
- The low-smoke halogen-free outer sheath is manufactured using an extrusion molding process, balancing environmental protection and safety performance. It features clear labeling for easy traceability.
- Routine Inspections
- Typical inspections include conductor resistance, insulation thickness, spark testing, voltage testing, dimensional inspection, sheath integrity, and armor coverage verification.
- 2C for Single-Phase Conduit Distribution (Depending on Design)
- 3C for Three-Phase Circuits Without Neutral (Depending on Design)
- 4C for Three-Phase Distribution with Neutral (Common)
- 5C for Three-Phase Distribution with Neutral and Protective Power (Depending on Design)
- 1C Armored Single-Core Feeder Can Be Used According to Design Specifications
4 6 10 16 25 35 50 70 95 120 150 185 240 300
- 4C x 10 4C x 16 4C x 25 4C x 35 4C x 50
- 3C x 10 3C x 16 3C x 25 3C x 35
- 5C x 10 5C x 16 5 cores x 25
- 1 core x 70 1 core x 95 1 core x 120 1 core x 150
- Model:
- WDZ-YJY23
- Cable Type:
- Low Smoke Halogen-Free (LSZH) XLPE Insulated Copper Core Low Voltage Power Cable, with Steel Tape Armor
- Rated Voltage:
- 0.6/1 kV
- Conductor:
- Copper, Stranded Wire
- Insulation:
- XLPE
- Armor:
- Steel Tape Armor (Type 23, specific specifications depend on standard)
- Outer Sheath:
- LSZH (Low Smoke Halogen-Free)
- Core Wire Specifications:
- 1 core, 2 cores, 3 cores, 4 cores, 5 cores (as needed)
- Common Specifications:
- 4 to 300 mm² (depending on core count and standard)
- Typical operating temperature:
- XLPE insulation design up to 90°C (specific specifications depend on standard)
- Typical installation:
- Underground conduit, trench, utility corridor protection wiring
- Packaging:
- Export reel (common packaging for armored cables); coil packaging available for smaller gauge cables (if applicable)
- Options:
- Markup language, reel length diagram, packaging marking, documentation suite, inspection support
When Low Smoke Halogen-Free (LSZH) performance is required and the line requires armored mechanical protection, select WDZ-YJY23.
Please confirm the following in the Bill of Materials (BOQ):
- LSZH requirements and acceptance criteria
- Armor type requirements (23 layers of steel tape) and line conditions (conduit, trench, outdoor)
- Select the core count based on the distribution design (three-phase, neutral/protection pole scheme).
- Select the cross-sectional area based on current, line length, grouping, soil/conduit thermal conditions, and permissible voltage drop.
- Determine the recommended reel length to reduce the number of joints in conduits and trenches.
- Product:
- WDZ-YJY23
- Voltage:
- 0.6/1 kV
- Standard Requirements:
- __
- Low Smoke Halogen-Free (LSZH) Requirements:
- __
- Armor Type:
- 23 Steel Strip
- Core Configuration:
- __
- Cross-section Dimensions and Quantity:
- __
- Total Length:
- __ meters
- Installation Path:
- Underground Conduit/Trench/Utility Corridor/Protected Outdoor
- Destination:
- Country and Port __
- Trade Terms:
- __
- Packaging:
- Reel
- Preferred Reel Length:
- __
- Required Documents:
- __
- Remarks:
- Markup Language, Delivery Schedule, Inspection Requirements
- Q1 What is WDZ-YJY23 primarily used for?
- A It is used for low-voltage fixed installation paths requiring Low Smoke Halogen-Free (LSZH) performance and additional mechanical protection, such as underground conduits, trenches, and protected outdoor feeder paths.
- Q2 What does "23" mean in this cable model number?
- A "23" usually indicates a steel tape armored construction to enhance the mechanical protection of the cable path.
- Q3 What is the difference between WDZ-YJY and WDZ-YJY23?
- A WDZ-YJY is usually an unarmored cable, suitable for protected paths; while WDZ-YJY23 is steel tape armored, suitable for higher mechanical risks and underground conduit or trench installations.
- Q4 What is the voltage of WDZ-YJY23?
- A It is usually supplied as a 0.6/1kV low-voltage armored power cable.
- Q5 What are the commonly used specifications for underground low-voltage feeders?
- A 10 to 50 mm² specifications are suitable for feeders in many buildings; while 70 to 240 mm² and above are used for higher loads or longer distances, depending on voltage drop requirements.
- Q6 What details can help you provide an accurate quote?
- A. Required standards, low-smoke halogen-free acceptance criteria, number of coils, size list, total meters, route type, drum length plan, destination, and documentation requirements.
JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.
JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.
JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.
While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.
JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.