NH-VV Fire-Resistant PVC Power Cable 0.6/1kV for Critical Circuits

NH-VV Fire-Resistant PVC Power Cable 0.6/1kV for Critical Circuits

Brand Name: JinHong
Model Number: NH-VV
MOQ: 100m
Price: 5.15-20 USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Standardscompliance:
IEC, BS, UL, Or IEEE
Cabletype:
Armored Or Unarmored
Currentrating:
Depends On Cable Size And Installation Conditions
Mechanicalprotection:
Steel Wire Armor Or Steel Tape Armor
Installationmethod:
Underground, Overhead, Or Indoor
Sheathmaterial:
PVC, PE, Or LSZH
Flameretardant:
Yes/No
Productname:
Industrial Power Cables
Conductormaterial:
Copper Or Aluminum
Application:
Power Distribution In Industrial Environments
Insulationmaterial:
PVC, XLPE, Or Rubber
Numberofcores:
1 To 5 Cores
Oilresistance:
Yes/No
Temperaturerange:
-40°C To +90°C
Voltagerating:
0.6/1kV To 33kV
Highlight:

0.6/1kv low voltage cable

,

unarmored low voltage cable

Product Description
NH-VV Fire-Resistant Low-Voltage PVC Power Cable

Ensure the continuous operation of critical systems during critical moments. NH-VV is a fire-resistant low-voltage PVC power cable designed for fixed wiring where the integrity of circuits requiring emergency loads, building safety systems, and critical power distribution needs to be guaranteed.

Product Overview

NH-VV is a low-voltage copper core power cable with PVC insulation and a PVC outer sheath, manufactured with a fire-resistant structure. It maintains electrical continuity for a period of time under fire conditions (performance depends on required standards and test categories). It is widely used in emergency lighting, fire pumps, smoke extraction systems, alarm systems, evacuation systems, and other life-safety circuits that must remain operational during a fire. Compared to standard VV cables, NH-VV cables are suitable for applications where project specifications require fire resistance, not just flame retardancy.

Low Voltage Ratings
  • Typical Rated Voltage: 0.6/1 kV
  • Applications: Fixed low-voltage power supply and control distribution
  • Project Notes: Must meet the fire resistance test requirements specified in the Bill of Quantities (BOQ)
NH-VV Application Areas
Typical Applications
  • Emergency lighting and evacuation guidance circuits
  • Power supply for fire alarm, detection, and notification systems
  • Fire pumps, sprinkler control systems, and critical machinery
  • Power supply for smoke exhaust and booster fans
  • Critical building equipment in public utilities and high-occupancy buildings
  • Industrial sites requiring uninterrupted power supply for emergency shutdown and safety systems
Typical Installation Methods
  • Cable trays, conduits, risers, shafts, and protective wiring within buildings
  • Fixed installation only
General Specifications Overview
Common Core Wire Configurations (Depending on the project)
  • 1C for single-core feeders and dedicated circuits
  • 2C for single-phase power supplies
  • 3C for three-phase circuits without a neutral (specific design depends on the situation)
  • 4C for three-phase distribution with a neutral
  • 5C For three-phase systems with neutral and PE (specific design depends on the situation)
Common cross-sectional dimensions (mm²)

1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240

High-demand combinations
  • 2C x 1.5, 2C x 2.5, 2C x 4
  • 3C x 2.5, 3C x 4, 3C x 6
  • 4C x 10, 4C x 16, 4C x 25, 4C x 35
  • 5C x 10, 5C x 16, 5C x 25
Key purchasing advantages
  • Fire-resistant circuit integrity for critical loads

    Utilizing an NH fire-resistant structure, it can maintain power supply to critical systems in the event of a fire, meeting building safety requirements.

  • PVC/PVC structure, an economical and efficient fixed cabling solution

    PVC insulation and sheathing provide a practical and widely applicable structure for low-voltage power distribution and installation.

  • A reliable choice for public and commercial buildings

    Commonly used in densely populated areas and projects with stringent safety requirements.

  • Facilitates Contractor and EPC Procurement

    Universal sizes, predictable construction processes, and multiple documentation options support Bill of Quantities (BOQ) compliance and phased delivery.

Structural Overview
  • Conductor: Copper stranded wire
  • Insulation: PVC
  • Fire-resistant layer: Fire-resistant design based on required test categories (project specifications)
  • Outer Sheath: PVC
  • Installation Type: Fixed cabling and distribution circuits
Manufacturing and Process Description
  1. Copper Conductor Preparation

    Copper is drawn and stranded to meet resistance targets and stable termination performance.

  2. Insulation Extrusion

    The PVC insulation layer is extruded with controlled thickness and concentricity to ensure consistent dielectric properties.

  3. Fire-resistant Component Integration

    Fire-resistant structural components are used to support the integrity of the circuit under fire-resistant testing conditions, according to project standards.

  4. Sheathing and Marking

    A PVC sheath is extruded to protect the internal structure and then marked for traceability and project control.

  5. Routine Inspections

    Typical inspections include conductor resistance, insulation thickness verification, spark testing, voltage testing, dimensional inspection, and sheath integrity checks.

Specifications
Item Details
Model NH-VV
Cable Type Fire-resistant PVC insulated, PVC sheathed low-voltage power cable
Rated Voltage 0.6/1 kV
Conductor Copper stranded wire
Insulation PVC
Outer Sheath PVC
Core Wire Specifications Single core, double core, triple core, four core, five core
Common Size Range 1.5 to 240 mm²
Typical Installation Methods Conduit, cable tray, shaft, riser, protective building wiring
Packaging Small gauge cables are packaged in reels; large gauge cables are packaged in export reels.
Optional Configurations Markup language, packaging markings, reel length diagram, document suite
Selection Guide
  1. Select NH-VV when your bill of quantities requires fire resistance and circuit integrity for critical systems.
  2. Please confirm the required fire resistance test category and duration in the project documents.
  3. Select the number of core wires and cross-sectional area based on load current, spacing, grouping method, ambient temperature, and allowable voltage drop.
  4. If the project also requires Low Smoke Halogen-Free (LSZH), please specify the use of LSZH fire-resistant material instead of PVC sheath.
Quick Inquiry Template
  • Product: NH-VV
  • Voltage: 0.6/1 kV
  • Fire Resistance Requirements and Duration: __
  • Standard Requirements: __
  • Core Wire Configuration: __
  • Cross-section and Quantity: __
  • Total Length: __ meters
  • Installation Path: Conduit/Trough/Riser/Shaft/Protective Path
  • Destination Country and Port: __
  • Trade Terms: __
  • Packaging: Reel/Roll
  • Required Documents: __
  • Remarks: Marking language, delivery schedule, inspection requirements
Frequently Asked Questions
  • Q1 What is the purpose of NH-VV?

    A: NH-VV is used in critical low-voltage circuits that must maintain power supply in the event of a fire, such as emergency lighting, alarms, smoke extraction, and fire pumps.

  • Q2 Is NH-VV the same as flame-retardant cable?

    A: No. Flame-retardant cables focus on limiting the spread of flames, while fire-resistant cables focus on maintaining circuit integrity in the event of a fire. NH indicates the fire resistance requirement.

  • Q3 What is the typical rated voltage?

    A NH-VV is typically used as a 0.6/1kV low-voltage power cable for fixed installations.

  • Q4 What are the commonly used cable specifications for building safety systems?

    A Emergency lighting and control power supplies typically use 1.5 to 10 mm² cables, while feeders for large safety equipment typically use 16 to 70 mm² cables, depending on the load and distance.

  • Q5 What information is needed for a quick quote?

    A Fire resistance duration/rating, standard, conductor configuration, specification sheet, total length (meters), installation route, destination, and packaging requirements.

  • Q6 Can NH-VV be used in underground conduits?

    A Primarily for building wiring. Underground use depends on wiring protection measures and local regulations. For situations with underground mechanical risks, consider using armored cables if necessary.

Service of JinHong Company
  • Over Productions Service:

    JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

  • Quality Certification Services:

    JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

  • Profession Customer Service:

    JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

  • Delivery And Shipping Services:

    While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

  • Packaging of JinHong:

    JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.