WDZ-YJY23 XLPE LSZH Cable 3 Core Armoured Cable 16mm Underground Use
Product Summary
Product Details
WDZ-YJY23 XLPE LSZH Cable
,XLPE LSZH Cable 3 Core
,3 Core Armoured Cable 16mm
Product Description
WDZ-YJY23 LSZH XLPE STA Armored LV Cable 0.6/1kV for Underground Projects
WDZ-YJY23 is a low-voltage copper core power cable designed for fixed installation environments that meet underground laying and fire safety regulations. It features cross-linked polyethylene (XLPE) insulation for reliable low-voltage distribution; steel tape armor (STA) enhances its resistance to external pressure and laying stress; and the outer sheath is made of low-smoke halogen-free (LSZH) material, effectively reducing smoke and corrosive halogen gases generated in a fire. This cable is commonly used in underground conduits, cable trenches, service corridors, and building access lines, where standard unarmored LSZH cables may face a higher risk of damage during traction, backfilling, and long-term laying.
- Underground cable trench feeders in commercial and industrial areas
- Protective power distribution lines laid in trenches within factories and industrial parks
- Incoming lines to main distribution panels in buildings
- Service tunnels, cable corridors, and utility corridors
- In public utilities, enclosed or interconnected lines must meet Low Smoke Halogen-Free (LSZH) requirements
- Projects requiring armor protection to reduce installation and compression damage
- Conduit and cable trench systems, protected trenches, cable corridors, protected tunnel lines
- Fixed installation only
- Copper stranded wire (conductor class meets required standards)
- 1C for high-current feeders and phase-separated wiring
- 2C for auxiliary low-voltage power supplies and dedicated single-phase loads
- 3C for three-phase circuits without a neutral conductor (depending on design)
- 4C for three-phase distribution with a neutral conductor
- 5C for three-phase distribution with a neutral conductor and protective insulation (PE) Power distribution (depending on design)
Common feeder layouts in Building Quantity Lists (BOQ) are 3+1 and 3+2 structures.
- 4 core x 25
- 4 core x 35
- 4 core x 50
- 5 core x 16
- 5 core x 25
- 5 core x 35
- 3 core x 16
- 3 core x 25
- 1 core x 150
- 1 core x 185
- 1 core x 240
3+1 and 3+2 structures are based on local design and BOQ. Specific requirements will apply.
Note: Final supply depends on the required standards, conductor class, low smoke halogen-free (LSZH) composite system, and armor construction.
Designed to reduce smoke concentration and the release of corrosive halogen gases, thereby improving evacuation conditions and reducing secondary corrosion of equipment in enclosed wiring.
Steel tape armor resists external pressure and line compression, improving the durability of ductwork, trenches, and service corridors.
XLPE insulation offers stable dielectric and thermal properties, suitable for feeders and branch lines.
The armor layer and controlled manufacturing process help reduce damage during pull-out, bending, backfilling, and long-distance field handling.
Standard low-voltage ratings, universal configurations, export-ready drum supply, and accompanying documentation facilitate repeat orders from contractors, distributors, and EPC contractors.
-
Conductor Control
The copper stranded wire is controlled to meet resistance targets and withstand actual bending during installation.
-
Cross-linked polyethylene (XLPE) Insulation and Cross-linking
The insulation layer is formed using extrusion and cross-linking processes to create a robust dielectric layer suitable for low-voltage applications.
-
Layup and Stabilization
The cores are assembled with controlled geometry before armoring to improve roundness and dimensional consistency.
-
Armor Applications
The steel strip is wound using a controlled overlap method, primarily providing mechanical protection against external pressure and compression.
-
Low Smoke Halogen-Free Sheath
The low smoke halogen-free sheath is produced using an extrusion molding process to protect the inner conductor layer and meet specified low smoke halogen-free performance requirements.
-
Routine Quality Inspections
Typical release checks include conductor resistance, insulation thickness control, voltage testing, spark testing, dimensional inspection, and sheath integrity verification. Other conformity verifications will be performed according to specified standards and classifications.
- Confirm the required standards and relevant terms in the Low Smoke Halogen-Free (LSZH) performance Bill of Materials (BOQ)
- Select core configuration based on neutral/protective electrical (PE) design and feeder scheme
- Determine dimensions based on load current, path length, grouping, ambient temperature, and voltage drop limitations
- Define path type: cable trench, conduit, tunnel, corridor, or inlet
- Specify preferred reel length to reduce joints and speed up installation
- If there are special risks associated with the path (impact, rodents, immersion, chemical exposure), specify them in the Request for Quotation (RFQ) for proper matching
-
Over Productions Service:
JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.
-
Quality Certification Services:
JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.
-
Profession Customer Service:
JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.
-
Delivery And Shipping Services:
While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.
JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.