products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Armoured Electrical Cable
Created with Pixso.

Underground Feeders YJLHV22 STA Cable PVC Aluminum XLPE Cable

Underground Feeders YJLHV22 STA Cable PVC Aluminum XLPE Cable

Brand Name: JinHong
Model Number: YJLHV22
MOQ: 200m
Price: 8.65-25USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Jacket Color:
Black
Cable Type:
Fire Resistant Armoured Electrical
Halogen Content:
Low
Voltage:
HV
Insulation:
XLPE/PVC
Cablelength:
Available In Standard Reels Or Customized Lengths
Armouringmaterial:
Steel Wire Or Steel Tape
Test Voltage:
35KV
Sheath:
PVC, Pe, Lsoh
Color:
Optional
Screen Material:
Copper Tape
Sheath Material:
PVC
Item No:
YJV22 N2XRY
Cabletype:
Armoured
Standardscompliance:
IEC, BS, UL, Or Other Relevant Standards
Highlight:

Underground Feeders YJLHV22 STA Cable

,

PVC Aluminum XLPE Cable

,

YJLHV22 Aluminum XLPE Cable

Product Description

YJLHV22 Aluminum XLPE PVC STA Armored Cable 0.6/1kV for Underground Feeders

YJLHV22 is a low-voltage aluminum core power cable designed for cost-effective power distribution with enhanced mechanical protection. It typically consists of an aluminum core conductor, cross-linked polyethylene (XLPE) insulation, and a steel tape armor (STA) layer, all sheathed with polyvinyl chloride (PVC). This construction is widely used in underground and protected fixed installations where external pressure, trench backfill stress, and line durability are critical considerations. YJLHV22 is commonly used in building feeders, industrial park power distribution, campus utilities, and long-distance low-voltage lines, where the aluminum core conductor, when properly sized, reduces material costs while maintaining reliable performance.

Rated Voltage

Typical Rated Voltage: 0.6/1 kV

Applications

Low-voltage feeders and distribution lines (fixed installation)

Important Note: Please confirm the required standards, conductor class, and acceptance tests specified in the Bill of Materials (BOQ).

Common Specifications Overview
Common Core Configurations (Depending on Project)
  • 1C: High-current feeder with phase-separated wiring
  • 2C: Dedicated single-phase power distribution and auxiliary power supply
  • 3C: Three-phase circuit without neutral (Depending on Design)
  • 4C: Three-phase power distribution with neutral (Widely used)
  • 5C: Three-phase power distribution with neutral and PE (Depending on Design)
  • 3+1 and 3+2: Commonly used feeder structures in many bills of quantities
Common Cross-sectional Dimensions (mm²)

16 25 35 50 70 95 120 150 185 240 300 400

High-Frequency Procurement Combinations
  • 4C x 25 4C x 35 4C x 50
  • 4C x 70 4C x 95
  • 5C x 25 5C x 35 5C x 50
  • 3C x 35 3C x 50 3C x 70
  • 1C x 120 1C x 150 1C x 185 1C x 240
  • 3+1 and 3+2 kits, designed according to local supplier

Note: Availability depends on required standards, armor construction, and sheath formulation.

Applications of YJLHV22
Typical Applications
  • Underground cable trenches and trench distribution
  • Incoming lines to main low-voltage switchboards in buildings
  • Installation corridors for industrial and utility facilities requiring armor protection
  • Campus and residential development distribution networks
  • Long-distance low-voltage lines with cost advantages of aluminum
  • Lines requiring compression protection
Typical Installation Methods
  • Protected cable trenches, conduits, cable corridors, service tunnels, protected fixed lines
Key Purchasing Advantages
Aluminum conductors for cost-effective power distribution

Aluminum conductors meet low-voltage power distribution requirements while reducing costs for long-distance and large-section lines (provided the size is chosen appropriately).

STA Armor, Providing Mechanical Protection

Steel tape armor enhances resistance to external pressure and compression, improving the reliability of underground cable trenches and ducts.

XLPE Insulation, Ensuring Stable Electrical Performance

XLPE insulation provides reliable dielectric strength and thermal properties for continuous load feeders.

PVC Sheath, Ensuring Installation Durability

The PVC outer sheath is widely applicable, suitable for fixed installations, and features good abrasion resistance and ease of handling.

Facilitating Procurement by EPC Contractors and Distributors

Common size ranges, standardized constructions, and export-grade drum supply support phased delivery and inventory planning.

Structural Overview
  • Conductor: Aluminum
  • Insulation: Cross-linked polyethylene (XLPE)
  • Padded layer: Protective padding layer beneath the armor layer
  • Armor layer: Steel tape (STA), often associated with "V22" construction in many naming systems
  • Outer sheath: PVC
  • Application: Low-voltage fixed installation, especially suitable for underground power distribution
Manufacturing and Processing Notes
Conductor Preparation

The aluminum conductor stranding is strictly controlled to meet the required flexibility and resistance targets, thereby ensuring stable termination and wiring installation.

XLPE Insulation Extrusion and Crosslinking

The insulation layer is extruded and crosslinked to form a robust dielectric layer suitable for low-voltage feeder applications.

Core Identification and Layup

Cores are identified and laid up in a controlled geometry to maintain roundness and dimensional stability.

Side Pad Formation

Side pads are laid to protect the core assembly and provide a smooth base for the armor.

Steel Tape Armoring

Steel tape is wound in a spiral pattern with controlled overlap to improve compressive strength and resistance to external pressure.

Sheath and Surface Finishing

An extruded PVC outer sheath protects the armor and insulation system and is marked for easy traceability and project control.

Routine Quality Inspections

Typical inspections include conductor resistance, insulation thickness verification, spark testing, voltage testing, dimensional inspection, and sheath integrity checks.

Specifications (can be copied directly)
Attribute Value
Model YJLHV22
Cable Type Aluminum core, cross-linked polyethylene (XLPE) insulated, polyvinyl chloride (PVC) sheathed, steel tape armored low-voltage cable
Rated Voltage 0.6/1 kV
Conductor Aluminum stranded wire
Insulation Cross-linked polyethylene (XLPE)
Armor Steel tape (STA)
Outer Sheath Polyvinyl chloride (PVC)
Core Configuration 1 core, 2 cores, 3 cores, 4 cores, 5 cores, 3+1, 3+2
Common Cross-sectional Area 16 to 400 mm²
Typical Operating Temperature Up to 90°C (XLPE design, depending on standards)
Installation Methods Underground conduit, cable trench, trench, protective corridor
Packaging Most specifications are packaged in reels; export packaging is available.
Optional Configurations Custom markings, reel length planning, accompanying documentation
How to Select the Right YJLHV22 Cable
  1. Please confirm the standards and conductor requirements referenced in your Bill of Materials (BOQ).
  2. Select the correct aluminum conductor size to handle current and voltage drops, especially for long-distance layups.
  3. Select the core configuration based on the neutral and protective layer (PE) design.
  4. Confirm the type of layup and whether additional mechanical protection is required.
  5. Specify the preferred reel length to reduce joints and speed up installation.
  6. If there are areas with water immersion, chemicals, or special soil conditions, please specify the environmental conditions.
Quick Inquiry Template
Product: YJLHV22
Voltage: 0.6/1 kV
Core Wire Configuration: __
Cross-section and Quantity: __
Total Length: __ meters
Installation Path: Cable Trench/Trench/Corridor/Inlet Line
Required Standards: __
Destination: Country and Port __
Trade Terms: __
Preferred Reel Length: __
Required Documents: __
Remarks: Marking Language, Packaging Markings, Delivery Schedule
Frequently Asked Questions
  • What are the main uses of YJLHV22?

    It is used for cost-effective low-voltage power distribution with armored protection, typically in underground cable trenches, trenches, and protective wiring, suitable for building and industrial feeders.

  • Why choose aluminum conductors instead of copper conductors?

    Aluminum conductors reduce material costs for long-distance and large-cross-section lines. Proper sizing and termination are crucial for ensuring reliable performance.

  • What does V22 usually stand for?

    In many naming systems, it refers to a steel tape armored, PVC sheathed construction. Please always follow the definitions in the reference standard.

  • Is YJLHV22 suitable for direct burial?

    It is typically installed in conduits and protective trenches. The suitability for direct burial depends on soil conditions, mechanical risks, and local regulations. Please provide route details for proper selection.

  • What are the commonly used procurement specifications?

    25 to 95 mm² 4-core and 5-core cables are commonly used for building and campus power distribution. 120 to 240 mm² single-core cables are commonly used for high-current feeders, depending on the load and distance.

  • What details are needed for a quick quote?

    Core configuration, cross-section, total meters, required standards, installation route, packaging preferences, and destination.

Service of JinHong Company
  • Over Productions Service:

    JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

  • Quality Certification Services:

    JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

  • Profession Customer Service:

    JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

  • Delivery And Shipping Services:

    While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.