1.5mm2 To 1000mm2 Steel Tape Armored Cable WDZ-YJY23 LSZH XLPE

1.5mm2 To 1000mm2 Steel Tape Armored Cable WDZ-YJY23 LSZH XLPE

Brand Name: JinHong
Model Number: WDZ-YJY23
MOQ: 200m
Price: 15-45.99USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Insulated:
XLPE
Working Temp:
90 ºC
Voltage:
18/30 36kV 19/33 36 KV
Feature:
PVC Sheath
Insulation Material:
Xlpe
Product Type:
MV Al Cable
Product Model:
AL/XLPE/SWA/PVC Cable
Application:
Underground, Industrial, And Outdoor Installations
Sheathmaterial:
PVC Or PE
Crosssectionalarea:
1.5mm² To 1000mm²
Standard:
IEC60502
Test Voltage:
3.5KV
Operatingtemperaturerange:
-15°C To +90°C
Temperature Rating:
0°C To +90°C
Highlight:
Mv Power Cable, Swa Power Cable
Product Description
WDZ-YJY23 LSZH XLPE Steel Tape Armored Cable 0.6/1kV for Underground
WDZ-YJY23

WDZ-YJY23 is a low-smoke halogen-free (LSZH) sheathed, cross-linked polyethylene (XLPE) insulated, and steel-tape armored low-voltage power cable designed for fixed installations with complex routing and clearly defined safety requirements. It is suitable for underground and protected distribution lines requiring additional resistance to external stresses, while reducing smoke emissions and the generation of corrosive halogen gases in the event of a fire. For contractors and engineering, procurement, and construction (EPC) contractors, WDZ-YJY23 is a practical choice, meeting the needs for line durability and enhanced fire resistance in enclosed or building connections.

Rated Voltage

Typical Low Voltage Rating: 0.6/1kV

Applications: Building feeders, industrial park power distribution, industrial low-voltage trunk and branch lines (fixed installation)

Uses
Common Practical Applications
  • Incoming lines from transformer areas to main low-voltage switchboards, with routes including buried or protected channels.
  • Underground conduits and piping systems in industrial parks, commercial complexes, and residential developments.
  • Protected trench routes, considering backfill pressure and long-term external loads.
  • Cable ducts, service corridors, and utility corridors, with safety management requirements conforming to Low Smoke Halogen-Free (LSZH) standards.
  • Low-voltage distribution lines in public utilities, where path protection and safety clauses are clearly specified in procurement documents.
Non-Preferred Situations
  • Mobile equipment, dragging, frequent bending, or flexible dragging services.
  • High-impact areas where additional mechanical protection requirements are not confirmed.
Common Specifications Overview
Common Core Layouts (Projects) (Depending on Specific Design)
  • 1C for high-current feeders and phase-separated cabling
  • 2C for dedicated single-phase feeders and auxiliary power supplies
  • 3C For three-phase circuits without a neutral conductor (depending on specific design)
  • 4C for three-phase distribution with a neutral conductor
  • 5C for three-phase distribution with a neutral conductor and protective grounding (depending on specific design)
  • 3+1 and 3+2 for feeder arrangements used in many Bills of Quantities (BOQs)
Common stock or ordered cross-sectional areas (mm²)

1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400

High-demand ordering examples for underground low-voltage distribution
  • 4C x 25 4C x 35 4C x 50
  • 5C x 16 5C x 25 5C x 35
  • 3C x 16 3C x 25
  • 1C x 150 1C x 185 1C x 240

Adapted to local design specifications 3+1 and 3+2 Constructions

Note: Final construction details depend on the required standards, conductor class, and Low Smoke Halogen-Free (LSZH) composite system.

Reasons for Buyers Upgrading to WDZ-YJY23
LSZH Sheath, Improved Fire Scenario

Choosing an LSZH sheath system reduces smoke concentration, limits the release of halogen-related corrosive gases, thereby improving visibility and reducing the risk of secondary damage to equipment in enclosed or building-connected wiring.

Steel Tape Armor, Enhanced Compression Resistance

Choosing steel tape armor enhances the cable's compression resistance and external stress resistance, which is particularly important for protected underground wiring, trench wiring, and congested utility corridors.

Cross-linked Polyethylene (XLPE) Insulation Formation

The insulation layer is extruded and cross-linked to form a robust dielectric layer suitable for low-voltage distribution applications.

Cable and Geometry Control

Core marking and strand length are controlled to maintain roundness, resulting in a smoother sheath and more stable traction performance.

Side Layer Preparation

Side layers are applied to protect the core assembly and provide a stable base for steel tape winding.

Armoring

Steel tape is wound in a controlled overlap pattern, primarily providing mechanical reinforcement against compression and external stress.

Low Smoke Halogen-Free (LSZH) Sheath

A low smoke halogen-free sheath is extruded to protect the armor layer and meet the project's low smoke halogen-free performance requirements.

Quality Release Inspections

Typical inspections include conductor resistance, insulation thickness verification, spark testing, voltage testing, dimensional control, and sheath integrity checks. All compliance checks meet specified standards.

Specifications (can be copied directly)
Product Model WDZ-YJY23
Cable Type Low-smoke halogen-free cross-linked polyethylene (XLPE) copper core power cable, steel tape armor
Rated Voltage 0.6/1kV
Conductor Copper, stranded wire
Insulation Cross-linked polyethylene (XLPE)
Armor Steel tape
Outer Sheath Low-smoke halogen-free (LSZH)
Common Core Wire Specifications 1 core, 2 cores, 3 cores, 4 cores, 5 cores, 3+1 cores, 3+2 cores
Common Wire Diameter Range 1.5 to 400 mm²
Typical operating temperature Up to 90°C (XLPE design, depending on standard)
Installation methods Conduit, underground protected wiring, protected trenches, cable trays, maintenance access
Packaging Export reels, reel lengths customizable
Optional services Custom marking, packaging marking, document kits, reel scheduling plans
How to choose the right specifications
  1. Confirm the wording of the Low Smoke Halogen-Free (LSZH) requirements in the Bill of Quantities. (BOQ)
  2. Select conductor configuration based on neutral and protective grounding design.
  3. Select cross-sectional area based on load current, line length, environmental conditions, grouping method, and allowable voltage drop.
  4. Clearly define the installation path (conduit, protective trench, utility access, inlet).
  5. Specify reel length preference to reduce joints and speed up installation.
  6. If the environment involves water, chemicals, or special mechanical risks, declare this in the Request for Quotation (RFQ) to select appropriate sheathing and protection solutions.
Quick Request for Quotation Template (Paste and Send)

Cable Type: WDZ-YJY23

Voltage: 0.6/1kV

Conductor Configuration: __

Size and Quantity: __

Total Length: __ meters

Installation Path: __

Required Standards and Classifications: __

Destination Country and Port: __

Trade Terms: __

Preferred Reel Length: __

Required Documents: __

Remarks: Low Smoke Halogen-Free (LSZH) Markup language and delivery schedule required

Frequently Asked Questions
  • How does WDZ-YJY23 differ from standard Low Smoke Halogen-Free (LSZH) power cable?

    It features added steel tape armor, providing better resistance to external pressure and installation stress, making it more suitable for protected underground lines and incoming lines.

  • What does "23" in the name mean?

    In many naming systems, "23" is associated with a steel tape armor construction. The specific definition must follow the standards specified in the project documentation.

  • Is WDZ-YJY23 suitable for flexible or mobile equipment?

    No. It is designed for fixed installations. For equipment that is frequently moved, choose a flexible cable designed for dynamic applications.

  • Can it be used for direct burial?

    It is typically used for protected underground lines. The suitability for direct burial depends on local regulations, soil conditions, and mechanical risks. Please provide line details for proper selection.

  • What is the most commonly used specification in projects?

    Multi-core 4-core and 5-core cables ranging from 16 to 50 mm² are widely used in power distribution; high-current feeders typically use single-core cables ranging from 120 to 240 mm², depending on the load and distance.

  • What information is needed for an accurate quote?

    Standard requirements, conductor configuration, size list, total length, route type, destination, reel preference, and required documentation.

Service of JinHong Company
Over Productions Service:

JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

Quality Certification Services:

JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

Profession Customer Service:

JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

Delivery And Shipping Services:

While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.