products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Armoured Electrical Cable
Created with Pixso.

WDZ-YJY23 LSZH XLPE STA Armored Power Cable 0.6/1kV For Underground Feeds

WDZ-YJY23 LSZH XLPE STA Armored Power Cable 0.6/1kV For Underground Feeds

Brand Name: JinHong
Model Number: WDZ-YJY23
MOQ: 200m
Price: 12.55-35 USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Highlight:

XLPE STA Armored Power Cable

,

WDZ-YJY23 STA Armored Power Cable

,

Armored Power Cable 0.6/1kV

Product Description

WDZ-YJY23 LSZH XLPE STA Armored Power Cable 0.6/1kV for Underground Feeds

Product Overview

WDZ-YJY23 is a low-voltage copper core power cable designed for fixed installations, meeting two key requirements:

  • Low Smoke Halogen-Free (LSZH) safety, reducing smoke and corrosive halogen gas emissions in fire scenarios;
  • Steel Tape Armor (STA) protection, enhancing the cable's ability to withstand external stresses in underground or mechanically sensitive lines;

WDZ-YJY23 is widely used in underground conduits, cable trenches, trenches, service tunnels, and building access lines, especially suitable for situations where installation stress, backfill pressure, or line compression risk is higher than standard indoor cable trays. If your tender requires low smoke halogen-free (LSZH) performance and the line includes underground sections, WDZ-YJY23 is a practical and compliant choice.

Rated Voltage

Typical Rated Voltage: 0.6/1 kV

System Type: Low-voltage distribution feeder and sub-feeder circuits

Note: Low Smoke Halogen-Free (LSZH) and flame retardant testing requirements shall comply with the standards specified in your Bill of Materials (BOQ).

Application Scenarios of WDZ-YJY23
Typical Project Application Cases
  • Building incoming lines from transformer rooms to main low-voltage switchboards
  • Campus power distribution in underground conduits and protection corridors
  • Low-voltage power distribution in industrial plants in trenches and utility corridors
  • Public utilities with designated enclosed lines using Low Smoke Halogen-Free (LSZH)
  • Stationary power distribution lines in cable corridors and service tunnels
  • Lines with armor selected to reduce the risk of damage under traction, backfilling, and long-term external stress
Scenarios where WDZ-YJY23 is generally not recommended
  • Flexible drag applications and environments with frequent movement
  • Unprotected lines directly buried in harsh soils without confirmation of local regulations and additional protection requirements
Common Specifications Overview
Common Core Wire Configurations (Depending on the Project)
  • 1C: High-current feeder, phase-separated wiring
  • 2C: Single-phase feeder and auxiliary circuit
  • 3C: Three-phase circuit without neutral wire
  • 4C: Three-phase circuit with neutral wire
  • 5C: Three-phase circuit with neutral wire + PE
  • 3+1, 3+2: Commonly used feeder structures in many building projects
Common cross-sectional dimensions (mm²) in procurement
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400
Common combination specifications
  • 4C x 16, 4C x 25, 4C x 35, 4C x 50
  • 5C x 10, 5C x 16, 5C x 25, 5C x 35
  • 3C x 10, 3C x 16, 3C x 25
  • 1C x 120, 1C x 150, 1C x 185, 1C x 240
  • 3+1 and 3+2 Combination specifications depend on local feeder design.
Why the buyer specifies model: WDZ-YJY23
Low Smoke Halogen-Free (LSZH) Advantages, Suitable for Enclosed Lines

LSZH sheathing systems are designed to provide clearer evacuation conditions and reduce the impact of corrosive gases on equipment during fires, especially suitable for shafts, corridors, and service tunnels.

Armored Protection, Ensuring Underground Reliability

STA armor is typically used to improve resistance to pressure and external stresses, thereby ensuring stable operation of conduits, trenches, and underground corridors.

XLPE Insulation, Ensuring Stable Low-Voltage Operation

XLPE insulation material has stable dielectric and thermal properties, suitable for long-distance feeders and continuous load distribution.

Reduced Contractor and EPC Delivery Risk

Recognized construction and common dimensions help reduce substitution risks and improve Bill of Quantities (BOQ) matching, especially in multi-stage delivery scenarios.

Product Structure Details (Clear and Easy to Understand, Facilitating Procurement)
  • Conductor: Copper (stranded; conductor grade conforms to standards)
  • Insulation: Cross-linked polyethylene (XLPE)
  • Inner Layer: Filler/adhesive added as needed to ensure roundness and stability
  • Padded Layer: Protective padding layer for supporting the armor
  • Armor: Steel tape armor (STA), often associated with a "23" construction in many markets
  • Outer Sheath: Low smoke halogen-free (LSZH) compound system
  • Installation Type: Fixed installation, especially suitable for underground protection lines
Manufacturing and Process Description (For Technical Procurement Personnel)
  1. Step 1: Conductor Stranding

    The copper wire drawing and stranding process is strictly controlled to ensure resistance stability and a workable bending radius during drawing.

  2. Step 2: Cross-linked polyethylene (XLPE) Insulation and Cross-linking

    The insulation layer is extruded and cross-linked to form a robust dielectric layer designed specifically for low-voltage distribution applications.

  3. Step 3: Core Identification and Routing

    Identify the cores as required (by color or number) and route them in a controlled geometry to ensure cable stability and ease of installation.

  4. Step 4: Pad Formation

    Apply padding to protect the cable cores and provide a smooth surface for armor layer installation.

  5. Step 5: Steel Tape Armoring

    Wrap steel tape in a controlled overlap pattern, primarily providing mechanical protection against external pressure and compression.

  6. Step 6: Low-Smoke Halogen-Free Sheath Extrusion

    Extrude a low-smoke halogen-free sheath to protect the armor layer and provide target smoke/corrosive gas performance as specified.

  7. Step 7: Routine Testing

    Typical checks include conductor resistance, insulation thickness control, spark testing, voltage testing, dimensional inspection, sheath integrity, and necessary verifications according to specified standards.

Specifications (can be copied directly)
Model
WDZ-YJY23
Cable Type
Low-smoke halogen-free cross-linked polyethylene (XLPE) copper core power cable, steel tape armor
Rated Voltage
0.6/1 kV
Conductor
Copper stranded wire (compliant with relevant standards)
Insulation
Cross-linked polyethylene (XLPE)
Armor
Steel tape armor (STA)
Outer Sheath
Low-smoke halogen-free (LSZH)
Core Wire Specifications
1 core/2 cores/3 cores/4 cores/5 cores/3+1 cores/3+2 cores
Common Cross-sectional Area
1.5 to 400 mm² (custom sizes available upon request)
Typical continuous operating temperature
Up to 90°C (XLPE design, depending on standards)
Installation methods
Underground conduits, cable trenches, trenches, service tunnels, protective fixed lines
Packaging
Export reels, small sizes available in reel packaging, reel lengths customizable
Customization services
Marking languages, packaging markings, test documentation, reel list planning
Selection guide (How to order the right equipment)
  1. Confirm the required standards and Low Smoke Halogen-Free (LSZH) in the Bill of Materials (BOQ) Performance Requirements
  2. Select core configuration based on power grid design (neutral/protection layer strategy)
  3. Determine size based on load current, length, grouping, ambient temperature, and permissible voltage drop
  4. Confirm line type: cable trench, trench, tunnel, corridor, or inlet
  5. Determine reel length preference to reduce joints and speed up installation
  6. Specify if the line has a high impact risk or rodent risk to match the protection rating
Quick Inquiry Template (Paste into email/chat)
  • Product: WDZ-YJY23
  • Rated Voltage: 0.6/1 kV
  • Core Configuration: __
  • Cross-section and Quantity: __
  • Total Length: __ meters
  • Installation Line: Cable trench/trench/tunnel/building inlet
  • Required Standards: __
  • Destination Country and Port: __
  • Trade Terms: __
  • Reel Length Preference: __
  • Special Notes: Low Smoke Halogen-Free (LSZH) Requirements, Marking, Documentation, Inspection, Delivery Schedule
Frequently Asked Questions
  • What are the main applications of WDZ-YJY23?

    It is used for low-voltage power distribution, especially suitable for lines requiring Low Smoke Halogen-Free (LSZH) performance and steel tape armor protection, such as underground conduits, cable trenches, trenches, and incoming lines.

  • What does "23" construction typically represent?

    In many market practices, "23" usually refers to a steel tape armored construction. Specific definitions and testing scope must follow the standards referenced in the tender documents.

  • Why do underground lines require Low Smoke Halogen-Free (LSZH) protection?

    Many projects specify the use of Low Smoke Halogen-Free (LSZH) protection to reduce smoke and corrosive gases in enclosed or building-connected lines (e.g., tunnels, corridors, and shafts), thereby improving evacuation conditions and reducing the risk of secondary equipment damage.

  • Can WDZ-YJY23 be used for direct burial?

    It is typically used for protected underground lines, such as cable trenches and trenches. The suitability for direct burial depends on local regulations, soil conditions, and mechanical risks. Please provide detailed wiring routes for proper selection.

  • How to choose between single-core and multi-core cables?

    Single-core cables are typically used for high-current and phase-separated wiring. Multi-core cables simplify wiring and cable management in standard power distribution layouts. Load, wiring route limitations, and installation habits should be considered when selecting a multi-core cable.

  • What information helps expedite quotation and delivery date confirmation?

    Voltage, number of cores, cross-sectional area, total length in meters, required standards, installation route, destination, reel length requirements, and documentation requirements.

Service of JinHong Company
  • Over Productions Service:

    JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

  • Quality Certification Services:

    JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

  • Profession Customer Service:

    JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

  • Delivery And Shipping Services:

    While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

  • Packaging of JinHong:

    JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.