XLPE STA Flame Resistant Cable 1.5mm2 To 400mm2 ZR-YJV22 Waterproof

XLPE STA Flame Resistant Cable 1.5mm2 To 400mm2 ZR-YJV22 Waterproof

Brand Name: JinHong
Model Number: ZR-YJV22
MOQ: 100m
Price: 8.15-15.55 USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Conductormaterial:
Copper Or Aluminum
Cabletype:
Armored Or Unarmored
Mechanicalprotection:
Steel Wire Armor Or Tape Armor
Waterresistance:
Waterproof Or Water-resistant
Installationmethod:
Underground, Overhead, Or Indoor
Temperaturerange:
-40°C To 90°C
Sheathmaterial:
PVC, PE, Or LSZH
Application:
Power Distribution In Industrial Environments
Standardscompliance:
IEC, BS, UL, IEEE
Productname:
Industrial Power Cables
Flameretardant:
Yes
Numberofcores:
1 To 5 Cores
Voltagerating:
Up To 35kV
Cablelength:
Custom Lengths Available
Insulationmaterial:
PVC, XLPE, Or Rubber
Highlight:

XLPE STA Flame Resistant Cable

,

STA Flame Resistant Cable 1.5mm2

,

400mm2 ZR-YJV22 Waterproof

Product Description

ZR-YJV22 Flame-Retardant XLPE Copper STA Armored Power Cable 0.6/1kV

When your project requires both the robustness of underground installations and flame retardancy, the ZR-YJV22 is an ideal upgrade. It combines copper core conductivity, XLPE insulation, steel tape armor for conductor protection, and a flame-retardant PVC sheath system to help limit the spread of flames along cable routes within buildings and industrial installations.

Product Overview

The ZR-YJV22 is a low-voltage copper core power cable designed for stationary installations requiring mechanical protection and a flame-retardant rating. Its construction typically includes stranded copper conductors, XLPE insulation to ensure stable low-voltage performance, an inner protective layer with steel tape armor (STA) for enhanced compressive strength and resistance to external stresses, and a flame-retardant PVC outer sheath. "ZR" is generally used to indicate flame retardancy in its naming system, while "22" is broadly associated with steel tape armor construction. This model is widely used in underground conduits, protected trenches, cable corridors, building shafts, and incoming lines, where bills of quantities include safety clauses and line durability requirements.

Rated Voltage

Typical Rated Voltage: 0.6/1 kV

Applications: Low-voltage distribution feeders and branches (fixed installation)

Application Scenarios for ZR-YJV22
  • Low-voltage trunk lines entering buildings and passing through shafts and corridors
  • Underground conduits and cable trenches in commercial and industrial sites
  • Protective trench wiring within factories, parks, and infrastructure projects
  • Cable corridors and utility passages requiring armored protection
  • Dense cable lines requiring flame retardancy to reduce the risk of flame spread
When to Consider Other Models
  • If Low Smoke Halogen-Free (LSZH) performance is required: Select LSZH flame retardant type
  • If fire resistance (circuit integrity) is required: Select fire-resistant/NH type
  • If frequent relocation is required: Select flexible cable
Common Specifications Overview
Common Core Configurations (Depending on the Project)
  • Single-core high-current feeder (phase-separated) wiring
  • 2C Single-phase feeder and dedicated circuit
  • 3C Three-phase without neutral (depending on design)
  • 4C Three-phase plus neutral distribution
  • 5C Three-phase plus neutral plus protective power (depending on design)
  • 3+1 and 3+2 feeder configurations used in many Bills of Quantities (BOQs)
Common cross-sectional dimensions (mm²)

1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400

Fast-moving project combinations
  • 4C x 16 4C x 25 4C x 35 4C x 50
  • 5C x 10 5C x 16 5C x 25 5C x 35
  • 3C x 10 3C x 16 3C x 25
  • 1C x 95 1C x 120 1C x 150 1C x 185 1C x 240
Key Purchase Advantages
  • Flame Retardant Upgrade, Ensuring Cable Wiring Safety
    Using ZR-grade flame-retardant materials effectively limits the spread of flames along the cable, ensuring cable wiring safety in shafts, corridors, and dense wiring environments.
  • Armored Protection, Enhanced Underground Durability
    Steel tape armor enhances compressive strength and resistance to external pressure, reducing the risk of damage in conduits and protective trenches.
  • XLPE Insulation, Ensuring Stable Low-Voltage Performance
    XLPE insulation ensures reliable electrical performance under continuous low-voltage power distribution loads.
  • Copper Conductor, Strong Conductivity
    Copper conductors ensure efficient power supply over long distances and achieve stable voltage drop control.
  • Suitable for EPC projects and large bills of quantities procurement
    Common sizes and familiar structures facilitate bill of quantities matching, phased delivery, and repeat supply.
Structural Overview
  • Conductor: Copper stranded wire
  • Insulation: Cross-linked polyethylene (XLPE)
  • Side layer: Protective side layer beneath the armor layer
  • Armor layer: Steel tape (STA)
  • Outer sheath: Flame-retardant polyvinyl chloride (PVC)
  • Installation types: Fixed installation, underground, and protective wiring
Process and Technical Specifications
  1. Copper conductor stranding
    Controlled stranding structure helps improve resistance stability and facilitates installation.
  2. Cross-linked polyethylene (XLPE) insulation extrusion and cross-linking
    Insulation layer molding ensures durable dielectric properties in low-voltage distribution systems.
  3. Core identification and assembly
    Core wires are identified and stranded according to a controlled geometry to ensure consistent roundness and smoother pull-out.
  4. Side layer preparation
    Side layers are laid to protect the core wires and provide a stable base for the armor layer.
  5. Steel Strip Armor
    The steel strip is wound in a controlled overlapping manner to enhance its resistance to compression and external pressure.
  6. Flame-Retardant PVC Sheath and Marking
    A flame-retardant PVC sheath is extruded to protect the armor layer and meet the specified flame-retardant rating, followed by marking.
  7. Routine Inspections
    Typical inspections include conductor resistance, insulation thickness, spark testing, voltage testing, dimensional inspection, and sheath integrity.
Specification Table
Item Details
Model ZR-YJV22
Cable Type Flame-retardant XLPE insulated copper core STA armored PVC sheathed low-voltage power cable
Rated Voltage 0.6/1 kV
Conductor Copper stranded wire
Insulation Material XLPE
Armor Steel tape armor (STA)
Outer Sheath Flame-retardant PVC
Core Options Single core, Double core, Three core, Four core, Five core, Three core + Single core, Three core + Double core
Common Size Range 1.5 to 400 mm²
Typical Operating Capacity Maximum temperature up to 90°C (XLPE design, specific standards depend on the situation)
Installation Methods Pipe assemblies, conduits, protective trenches, corridors, shafts, fixed underground lines
Packaging Export reels (most sizes), coils (smaller sizes, depending on the project)
Options Markup language, packaging markings, reel length diagram, document suite
Selection Guide
  • When Bill of Quantities (BOQ) For applications requiring flame retardancy and armored protection for underground or protective wiring, select ZR-YJV22.
  • Select the number of cores based on the neutral and PE design.
  • Select the cross-sectional area based on current, distance, grouping, ambient temperature, and permissible voltage drop.
  • If low smoke halogen-free (LSZH) or fire-resistant properties are required, specify these requirements to match the correct model.
Quick Inquiry Template

Product: ZR-YJV22

Voltage: 0.6/1 kV

Required Standard: __

Flame Retardant Rating: __

Core Wire Configuration: __

Cross-section and Quantity: __

Total Length: __ meters

Installation Path: Cable Trench/Conduit/Protective Trench/Corridor/Shaft/Inlet Line

Destination Country and Port: __

Trade Terms: __

Preferred Reel Length: __

Required Documents: __

Remarks: Markup Language, Delivery Schedule, Inspection Requirements

Frequently Asked Questions

Question 1: What is the purpose of ZR-YJV22?

Answer: ZR-YJV22 is used for fixed-installation low-voltage power distribution, suitable for applications requiring a flame retardant rating and path protection using steel tape armor in cable trenches, culverts, and dense cable routes.

Question 2: What does ZR stand for?

Answer: ZR is generally used to indicate a flame retardant rating. Please match the required rating to your project standards.

Q3: What does 22 represent?

A: In many naming systems, 22 indicates a steel-tape armored structure, designed for compression resistance and line protection.

Q4: What is the difference between ZR-YJV22 and YJV22?

A: ZR-YJV22 has flame retardant requirements, while standard YJV22 may not meet flame retardant requirements unless otherwise specified.

Q5: Can ZR-YJV22 be used for underground installations?

A: Yes, it is commonly used for underground conduits and protective trenches, especially where a flame retardant rating is required.

Q6: What information helps expedite quotations and delivery schedules?

A: Required standards, flame retardant rating, core material configuration, size list, total meters, line type, destination, reel length requirements, and required documentation.

Service of JinHong Company
  • Over Productions Service:
    JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.
  • Quality Certification Services:
    JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.
  • Profession Customer Service:
    JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.
  • Delivery And Shipping Services:
    While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.
Packaging of JinHong

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.