products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Mineral Insulated Cable
Created with Pixso.

BTTWY Mineral Insulated Power Cable OEM ODM OBM Mineral Insulated Copper Cable

BTTWY Mineral Insulated Power Cable OEM ODM OBM Mineral Insulated Copper Cable

Brand Name: JinHong
Model Number: BTTWY
MOQ: 100m
Price: 10.5-20USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Conductor Type:
Solid
Durability:
High
Number Of Conductors:
Multicore
Feature:
Flexible,fire Resistance
Customized Support:
OEM, ODM, OBM, Software Reengineering
Minimum Bending Radius:
6 X Overall Diameter
Color:
Bright
Screen:
Extruded Semi-conducting Material
Insulationmaterial:
Magnesium Oxide (MgO)
Material:
Copper
Mechanicalstrength:
High Mechanical Strength And Durability
Standardscompliance:
Complies With IEC, BS, And Other International Standards
Flexibility:
Limited Flexibility Due To Rigid Construction
Sheath Colour:
White
Filler:
Flame Retardant Mineral
Highlight:

BTTWY Mineral Insulated Power Cable

,

Mineral Insulated Power Cable OEM

,

OBM Mineral Insulated Copper Cable

Product Description
BTTWY Mineral Insulated Cable 0.6/1kV for Fire-Resistant LV Emergency Power
BTTWY Mineral-Insulated Cable

BTTWY is a mineral-insulated, metal-sheathed low-voltage cable commonly used in fire-resistant and high-reliability low-voltage circuits. It is suitable for emergency power supplies, life-safety feeders, and critical building power systems that can operate stably under harsh high-temperature conditions, meeting project standard requirements.

Product Highlights

Critical circuits require better protection than standard insulation. BTTWY mineral-insulated cables are designed for demanding low-voltage lines where fire resistance, long-term reliability, and safer system operation are primary procurement considerations in public buildings and infrastructure projects.

BTTWY Introduction

BTTWY is generally considered a mineral-insulated (MI) metal-sheathed low-voltage power cable. The MI construction uses inorganic mineral insulation as the primary medium within a continuous metal sheath, rather than relying primarily on polymer insulation. This construction is commonly used in life-safety and emergency services because it ensures reliable circuit operation under fire exposure conditions, according to the acceptance plan. Depending on the route, handling requirements, and project requirements, an outer protective layer may be needed to improve abrasion resistance, facilitate identification, and installation.

Low Voltage Ratings
Typical Voltage Rating: 0.6/1 kV (depending on the project)
Typical Applications: Emergency feeders and critical low-voltage power circuits
Selection Guidelines: Meet the fire resistance requirements and acceptance criteria specified in your Bill of Materials (BOQ)
Applications of BTTWY
Typical Life Safety and Emergency Applications
  • Emergency lighting and evacuation route power supply
  • Fire control room power supply and critical monitoring circuits
  • Fire pump and critical fire equipment feeders
  • Smoke exhaust fan and booster system feeders
  • Elevator emergency power supply and critical vertical transportation circuits
  • Hospitals, public places, commercial buildings, and high-occupancy buildings
  • Metro stations, tunnels, airports, and transportation hubs requiring fire-resistant low-voltage cables
Typical Cabling Environments
  • Emergency shafts, shafts, and protected service corridors
  • Basements, machine rooms, and areas with dense cable distribution
  • Environmental project objectives requiring reduced smoke risk and improved line reliability (outer layer requirements depend on specific specifications)
Why Buyers Choose BTTWY
Fire Resistance and Circuit Integrity
  • MI is typically chosen when the design requires circuits to operate continuously in the harsh high-temperature environment specified in the project. Structure.
  • Provides stable low-voltage power to critical systems.
  • Inorganic insulation and a metallic sheath ensure long-term reliability for critical services.
Strong line durability.
  • The metallic sheath design provides reliable protection for a variety of fixed installation environments, enhancing the durability of critical lines.
Compliance-driven procurement.
  • When consultants and inspection teams require a MI (Made in-Mortar) structure for life safety circuits, BTTWY is often the preferred choice.
High lifecycle value.
  • For critical systems, reduced failure risk and smoother acceptance can offset higher initial costs, making BTTWY an ideal choice.
Structural Overview (Typical)
Conductor: Copper
Primary Insulation: Inorganic mineral insulation
Sheath: Metallic sheath (depending on specific construction)
Outer Layer: Optional protective outer sheath (as specified)
Armor: Usually not required as the metallic sheath already provides protection; additional protection paths may be added according to design.
Cable Type: MI type fire-resistant low-voltage power cable for fixed installations
Manufacturing and Process Description
  1. Conductor Preparation
    The copper conductor is treated to meet resistance and dimensional targets.
  2. Mineral Insulation Filling and Compacting
    Inorganic mineral insulation material is filled and compacted around the conductor to form the primary dielectric structure.
  3. Metallic Sheath Formation
    A continuous metallic sheath is formed around the insulated core wires to provide sealing and protection.
  4. Stabilization and Dimensional Control
    The cable undergoes stabilization and dimensional control to ensure consistent electrical performance and installation operation.
  5. Optional Outer Sheath
    A protective layer may be applied to improve abrasion resistance, facilitate identification, and expedite installation.
  6. Routine Inspections
    Typical inspection items include conductor resistance, electrical testing according to specified standards, sheath continuity verification, dimensional inspection, and marking inspection.
Common Specifications Overview
Common Core Quantity
  • 1 Core / 2 Core / 3 Core / 4 Core / 5 Core (Depending on Project)
Common Cross-sectional Dimensions (mm²)
  • 1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240
High-Demand Configuration Examples
  • 1 Core x 6
  • 1 Core x 10
  • 1 Core x 16
  • 2 Core x 2.5
  • 2 Core x 4
  • 2 Core x 6
  • 3 Core x 2.5
  • 3 Core x 4
  • 3 Core x 6
  • 4 Core x 10
  • 4 Core x 16
  • 4 Core x 25
  • 5 Core x 10
  • 5 Core x 16
  • 5 Core x 25
Specifications
Attribute Details
Model BTTWY
Category Mineral Insulated (MI) Metal Sheathed Fire-Resistant Low-Voltage Power Cable
Typical Rated Voltage 0.6/1 kV (depending on project)
Conductor Copper
Primary Insulation Inorganic Mineral Insulation
Sheath Metal Sheath (depending on construction)
Outer Sheath Optional, depending on wiring and handling requirements
Core Options 1 core/2 cores/3 cores/4 cores/5 cores
Typical Size Range 1.5 to 240 mm² (depending on core count and project standards)
Typical Applications Emergency lighting, fire pumps, smoke exhaust fans, life safety, and critical low-voltage circuits
Installation Fixed installation on emergency lines; line protection depends on project design
Packaging Small-size cables are packaged in reels; suitable for large-size cables and reels delivered on-site.
Options Sheath type, marking language, identification method, length planning, documentation package, inspection support
Buyer's Choice Checklist
  1. Confirm required fire resistance requirements and acceptance criteria (fire resistance time/rating and test methods)
  2. Confirm voltage rating and system configuration
  3. Select core count based on circuit design and neutral/protective conductor layout
  4. Based on current and line length Select cross-sectional area based on voltage, allowable voltage drop, and installation conditions.
  5. Confirm the wiring environment and whether sheathing is required.
  6. Confirm the termination kit and accessory requirements for MI cables.
  7. Plan the length to minimize joints on critical lines.
  8. Confirm the documentation package required for inspection, approval, and delivery.
Quick Inquiry Template
Product: BTTWY
Voltage Rating: __
Standard/Acceptance Criteria: __
Fire Resistance Requirements (Fire Resistance Time/Rating): __
Number of Cores: __
Cross-sectional Area and Quantity: __
Total Length (meters): __
Installation Route: Riser/Shaft/Tunnel/Corridor/Computer Room
Sheath Required: Yes/No, Type: __
Destination: Country and Port: __
Trade Terms: __
Packaging: Roll/Cylinder
Recommended Length: __
Required Documents: __
Frequently Asked Questions
Question 1: What is BTTWY mainly used for?
Answer: BTTWY is typically used for emergency and life safety low-voltage circuits, such as emergency lighting, fire pumps, and smoke extraction systems, where the fire resistance of these circuits must meet project requirements.
Question 2: What are the advantages of mineral insulation?
Answer: Mineral insulation uses inorganic mineral insulation materials and a metal sheath, making it suitable for critical circuits that need to operate reliably under harsh high-temperature and fire conditions.
Question 3: Is BTTWY suitable for public buildings and high-rise buildings?
Answer: Yes, BTTWY is often specified when emergency risers, shafts, and service access in public buildings and high-rise buildings have fire protection requirements.
Question 4: Do I need an outer sheath?
Answer: Many projects specify the use of an outer sheath to provide abrasion protection, easy identification, and ease of handling. Whether an outer sheath is needed depends on the wiring environment and acceptance criteria.
Question 5: What factors should be considered when terminating?
Answer: Insulated cables typically require compatible termination kits and proper termination techniques to maintain insulation integrity and sheath continuity. Please confirm the accessory system required for your project.
Question 6: What information is needed for an accurate quote?
A: Voltage level, fire resistance requirements, number of conductors, specification list, total length (meters), wiring type, whether an outer sheath is required, destination, packaging preferences, and documentation requirements.
Service of JinHong Company
Over Productions Service:

JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

Quality Certification Services:

JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

Profession Customer Service:

JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

Delivery And Shipping Services:

While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.