products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Low Voltage Cable
Created with Pixso.

LV Xlpe Insulated Armoured Cable 1.5mm2 To 1000mm2 Low Voltage Wire

LV Xlpe Insulated Armoured Cable 1.5mm2 To 1000mm2 Low Voltage Wire

Brand Name: JinHong
Model Number: YJV
MOQ: 100m
Price: 5.15-25 uSD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Temperaturerange:
-40°C To 90°C
Productname:
Industrial Power Cables
Insulationmaterial:
PVC, XLPE, Or Rubber
Conductormaterial:
Copper Or Aluminum
Flameretardant:
Yes
Voltagerating:
600V To 35kV
Numberofcores:
1 To 5 Cores
Oilresistance:
Yes
Installationmethod:
Underground, Overhead, Or Direct Burial
Application:
Power Distribution In Industrial Environments
Mechanicalprotection:
Steel Wire Armor Or Steel Tape Armor
Standardscompliance:
IEC, BS, UL, Or IEEE
Sheathmaterial:
PVC, PE, Or LSZH
Cablesizerange:
1.5mm² To 1000mm²
Cabletype:
Armored Or Unarmored
Highlight:

LV Xlpe Insulated Armoured Cable

,

1000mm2 Low Voltage Wire

,

Xlpe Insulated Armoured Cable 1.5mm2

Product Description

YJV is a copper-core, XLPE-insulated, PVC-sheathed low-voltage power cable, typically rated at 0.6/1kV, suitable for fixed installations. It is ideal for feeder and distribution lines in building, utility, and industrial projects, offering stable performance and convenient sourcing.

Product Highlights

YJV cables are a recognized cable type by purchasing personnel, contractors, and inspectors, helping you achieve standardization in low-voltage power distribution. YJV cables are designed for predictable installations, stable electrical performance, and convenient multi-stage project sourcing.

Product Introduction

YJV is a widely used low-voltage power cable for fixed installations. It typically uses stranded copper conductors to ensure efficient current transmission and reliable termination; the XLPE insulation provides strong dielectric properties; and the PVC outer sheath withstands the abrasion and installation stresses commonly encountered in the field. YJV cables are commonly used in low-voltage feeders, sub-feeders, and distribution lines, especially suitable for applications where project teams prioritize proven and reliable construction, a wide range of specifications, and field consistency.

Low Voltage Ratings
Typical Rated Voltage: 0.6/1 kV
Typical Applications: Fixed low-voltage distribution feeders and general power circuits
Typical Wiring Methods: Trays, conduits, cable trays, risers, shafts, and protected outdoor wiring
Application Scenarios (Scenarios Applicable to YJV Cables)
Common Application Examples
  • Main feeders from transformers or main distribution boxes to distribution panels and switchboards
  • Power supply for water pumps, HVAC systems, and general machinery
  • Power distribution circuits and machine power wiring in factories and warehouses
  • Commercial and residential buildings using standard low-voltage distribution
  • Infrastructure power distribution that complies with regulations allowing the use of PVC sheathing
Not applicable in the following situations:
  • Mandatory low-smoke halogen-free (LSZH) requirements
  • Emergency systems requiring fire-resistant circuit integrity
  • High mechanical risk wiring requiring armor or other protection
  • Needs moving, dragging, or bending cabling (choose flexible cables)
Reasons for Projects Choosing YJV Cables
Reliable low-voltage performance with cross-linked polyethylene (XLPE) insulation

XLPE Insulation materials are widely chosen for their stable and reliable low-voltage performance and consistent electrical properties in fixed installation applications.

Copper conductors reduce losses and ensure robust connections.

Copper conductors efficiently carry current and ensure consistent and reliable connection quality with common fittings.

Easy-to-procure standard models.

YJV models are readily available in common specifications or can be quickly produced, making them ideal for EPC project cycles and phased deliveries.

PVC sheath suitable for everyday field environments.

PVC sheaths provide practical abrasion resistance and protection in standard building and industrial applications.

Structure Overview
Conductor: Copper stranded wire
Insulation: Cross-linked polyethylene (XLPE)
Fill/Adhesive: As per construction standard requirements
Outer sheath: PVC
Armor: None (Standard YJV model; armored versions are a separate model series)
Installation method: Fixed installation
Manufacturing and Process Specifications
Conductor Stranding and Resistance Control

Copper stranding is controlled to meet resistance targets while maintaining installation flexibility.

XLPE Insulation Extrusion and Cross-linking

The insulation layer is extruded and cross-linked to form a uniform dielectric layer suitable for low-voltage distribution.

Core Identification and Routing

Cores are identified and stranded in a stable geometry to improve roundness and reduce tensile friction.

Sheath and Marking

Protected by a PVC sheath and printed for easy traceability and identification.

Routine Inspections

Typical inspections include conductor resistance, insulation thickness, spark/voltage testing, dimensional inspection, and sheath integrity (to standard).

Common Specifications Overview
Common Core Count
  • 1C for single-core feeders (installed according to local specifications)
  • 2C for single-phase circuits
  • 3C for three-phase circuits without a neutral (depending on design)
  • 4C for three-phase with a neutral (high-demand feeder option)
  • 5C for three-phase with a neutral and protective power (depending on design)
High-Demand Cross-Sectional Area (mm²)
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300
Common Combinations in Bill of Materials (BOQ)
2C x 2.5 2C x 4 3C x 4 3C x 6 3C x 10 4C x 10 4C x 16 4C x 25 4C x 35 4C x 50 5C x 10 5 cores x 16 5 cores x 25 1 core x 70 1 core x 95 1 core x 120 1 core x 150
Specifications (can be copied directly)
Model: YJV
Cable Category: Low-voltage power cable for fixed installation
Rated Voltage: 0.6/1 kV
Conductor: Copper stranded wire
Insulation: Cross-linked polyethylene (XLPE)
Outer Sheath: Polyvinyl chloride (PVC)
Armor: None (YJV standard)
Core Wire Specifications: 1 core/2 cores/3 cores/4 cores/5 cores
Common Specification Range: 1.5 to 300 mm² (depending on core count and gauge)
Typical Applications: Low-voltage feeders, sub-feeders, distribution lines
Installation Methods: Cable trays, conduits, cable trays, risers, shafts, outdoor protective installations
Packaging: Small-gauge reels; export-grade cable reels suitable for feeder systems
Customization Services: Marking language, sheath color, reel length options, packaging marking, documentation sets, inspection support
Quick Selection Guide
  1. Confirm voltage rating requirements (typically 0.6/1kV)
  2. Select core count based on system design and neutral/protection scheme
  3. Select conductor size based on current, distance, grouping, ambient temperature, and permissible voltage drop
  4. Confirm wiring conditions; specify armored or low-smoke halogen-free (LSZH) cables only if required by the Bill of Quantities (BOQ).
  5. Define reel lengths and splicing schemes to reduce field splicing and speed up installation.
Quick Inquiry Template
Product: YJV
Voltage: 0.6/1 kV
Required Standard: __
Core Wire Configuration: __
Cross-section and Quantity: __
Total Length: __ meters
Installation Path: Cable Tray/Conduit/Cable Tray/Riser/Shaft/Outdoor Protection
Destination: Country and Port __
Trade Terms: __
Packaging: Reel/Roll
Preferred Reel Length: __
Required Documents: __
Remarks: Markup Language, Inspection Requirements, Delivery Schedule
Frequently Asked Questions
Q1: What are the uses of YJV cables?
YJV cables are typically used for low-voltage feeders and distribution lines in fixed installation paths in buildings, industrial facilities, and general infrastructure.
Q2: What is the typical rated voltage?
YJV cables are typically supplied with a rated voltage of 0.6/1 kV for low-voltage distribution systems.
Q3: Are YJV cables suitable for underground installation?
A: They are typically used in conduits or to protect lines. For direct burial or high-risk mechanically hazardous lines, specify armored or line-grade cables according to project standards.
Q4 How to choose between 4-core and 5-core cables?
4-core cables are typically used for three-phase plus a neutral conductor; 5-core cables should be selected when a dedicated PE conductor is required. The final selection should follow your design and local regulations.
Q5 What are the common gauge sizes?
Gauges from 1.5 to 10 mm² are typically used for smaller distribution loops, while gauges from 16 to 50 mm² are typically used for feeders. Larger gauges, such as 70 to 300 mm², are used for higher loads and longer lines.
Q6 What information is needed for a quick quote?
A. Standard configuration, number of cores, size list, total meters, installation route, packaging preferences, destination, and required documents.
Service of JinHong Company
Over Productions Service:

JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

Quality Certification Services:

JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

Profession Customer Service:

JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

Delivery And Shipping Services:

While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.