products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Low Voltage Cable
Created with Pixso.

WDZ-YJY23 0.6/1kV Low Voltage Wire LSZH Armored XLPE Cable

WDZ-YJY23 0.6/1kV Low Voltage Wire LSZH Armored XLPE Cable

Brand Name: JinHong
Model Number: WDZ-YJY23
MOQ: 100m
Price: 8.15-45USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Sheathmaterial:
PVC Or PE (Polyethylene)
Standardscompliance:
IEC, BS, UL, IEEE
Installationmethod:
Underground, Overhead, Or Direct Burial
Voltagerating:
Up To 35kV
Application:
Power Distribution In Industrial Environments
Cabletype:
Armored Or Non-armored
Insulationmaterial:
XLPE (Cross-linked Polyethylene) Or PVC
Cablesizerange:
From 1.5 Mm² To 1000 Mm²
Oilresistance:
Yes
Shielding:
Available With Or Without Shielding
Conductormaterial:
Copper Or Aluminum
Temperaturerange:
-40°C To +90°C
Waterresistance:
Yes
Flameretardant:
Yes
Productname:
Industrial Power Cables
Highlight:

WDZ-YJY23 0.6/1kV Low Voltage Wire

,

Low Voltage Wire LSZH

,

LSZH Armored XLPE Cable

Product Description
WDZ-YJY23 LSZH Armored XLPE Cable 0.6/1kV for Duct and Trench Install
WDZ-YJY23

WDZ-YJY23 is a low-smoke halogen-free (LSZH) XLPE insulated copper core power cable with steel tape armor, suitable for 0.6/1kV low-voltage distribution. It is specifically designed for locations requiring low-smoke halogen-free performance and mechanical protection, such as conduits, trenches, and utility corridors.

Product Highlights

WDZ-YJY23 is designed to handle more complex wiring and safer indoor-outdoor transitions. Its low-smoke halogen-free performance and steel tape armor protection help contractors reduce wiring risks, minimize maintenance incidents, and meet compliance requirements.

Product Overview

WDZ-YJY23 is a low-voltage armored power cable typically featuring stranded copper conductors and XLPE insulation, protected by an inner insulation layer, a steel tape armor layer, and a low-smoke halogen-free outer sheath system. The LSZH sheath is suitable for projects requiring reduced smoke and halogen-free emissions in the event of a fire, helping to improve evacuation visibility and reduce the impact of corrosive gases. The steel-tape armor enhances the cable's resistance to compression and external mechanical stress, making it ideal for underground conduits, protected trenches, basement utility corridors, and sections subjected to construction loads.

Low Voltage Ratings
Typical Rated Voltage:
0.6/1 kV
Applications:
Fixed low-voltage feeders, sub-feeders, and distribution lines
Best Application Scenarios
  • Underground cable trenches and perimeter power distribution around buildings
  • Basement and utility corridor feeders with potential mechanical stress
  • Low-voltage power distribution in industrial and commercial parks
  • Indoor-outdoor transitions via bushings and conduits
  • Infrastructure corridors specifying Low Smoke Halogen-Free (LSZH) performance in enclosed spaces
  • Long feeder lines where armoring reduces the risk of line damage
Other Design Considerations

If the line is entirely indoors and on protected cable trays with low mechanical risk, unarmored LSZH cross-linked polyethylene (XLPE) cables may suffice.

If direct burial without cable tray protection is required, confirm project standards and develop a construction plan accordingly.

Why Buyers Choose WDZ-YJY23
Low Smoke Halogen-Free (LSZH) Performance, Safer Evacuation, and Reduced Corrosion

Low Smoke Halogen-Free (LSZH) materials help reduce smoke concentration, avoid the generation of corrosive halogen gases, thereby improving visibility and reducing secondary corrosion damage in enclosed wiring.

Protecting Pipes and Trenches for Reliability

Steel tape armor enhances resistance to pressure and external shocks, improving durability in underground and high-risk areas.

XLPE Insulation Ensures Stable Low-Voltage Feeder Operation

XLPE insulation ensures stable dielectric properties and provides reliable service for low-voltage distribution under continuous loads.

Sourcing Advantages for Complex Lines

Universal feeder sizes, repeatable construction, and exportable drum packaging support EPC delivery plans and phased procurement.

Structural Overview
  • Conductor: Copper stranded wire
  • Insulation: Cross-linked polyethylene (XLPE)
  • Backing: Inner protective layer at the armor interface (depending on standard)
  • Armor: Steel tape armor (Type 23)
  • Outer Sheath: Low smoke halogen-free (LSZH)
  • Installation: Fixed installation in conduits, trenches, corridors, and protected circuits
Process and Manufacturing Notes
Copper Stranded Wire and Resistance Consistency

The stranded wire is rigorously controlled to ensure stable resistance in the feeder circuit and predictable termination performance.

Cross-linked Polyethylene (XLPE) Insulation Extrusion and Cross-linking

The insulation molding process is designed to provide stable dielectric properties and better thermal performance under low voltage operation.

Core Assembly and Geometry Control

The core layup is carefully controlled to maintain stable roundness and improve stability during long-distance conduit transport.

Backing Application

The backing layer protects the insulated core wires and supports stable armor application.

Steel Strip Armor

Steel strips are wound with controlled overlap and tension, providing mechanical protection against compression and external stress.

Low Smoke Halogen-Free Sheath and Marking

Low smoke halogen-free sheaths are manufactured using an extrusion process, balancing safety and environmental friendliness, and feature clear printed markings for easy traceability.

Routine Inspections

Typical inspections include conductor resistance, insulation thickness, spark testing, voltage testing, dimensional inspection, sheath integrity, and armor coverage verification.

General Specifications Overview
Common Core Wire Configurations (Depending on Project)
  • 1C: For dedicated feeder circuits (armored single core when specified)
  • 2C: For single-phase distribution (Depending on Design)
  • 3C: For three-phase circuits without a neutral conductor (Depending on Design)
  • 4C: For three-phase circuits with a neutral conductor (Common)
  • 5C: For three-phase circuits with a neutral conductor and protective electrical wiring (Depending on Design)
Common Cross-sectional Areas of Armored Low-Voltage Feeders (mm²)
4 6 10 16 25 35 50 70 95 120 150 185 240 300
Common Configurations for Typical Projects
4C x 10 4C x 16 4C x 25 4C x 35 4C x 50
3C x 10 3C x 16 3C x 25 3C x 35
5C x 10 5C x 16 5-core x 25
1-core x 70 1-core x 95 1-core x 120 1-core x 150
Specifications (can be copied directly)
Model: WDZ-YJY23
Cable Type: Low Smoke Halogen-Free (LSZH) XLPE Insulated Copper Core Low-Voltage Power Cable, with Steel Tape Armor
Rated Voltage: 0.6/1 kV
Conductor: Copper, Stranded Wire
Insulation: XLPE
Inner Liner: Inner Protective Layer (depending on standard)
Armor: Steel Tape (Type 23)
Outer Sheath: LSZH (Low Smoke Halogen-Free)
Core Wire Specifications: 1 core, 2 cores, 3 cores, 4 cores, 5 cores
Common Specifications: 4 to 300 mm² (depending on core count and standard)
Typical operating temperature: Up to 90°C with XLPE insulation (depending on standard)
Installation methods: Underground conduit, protected trenches, utility corridors, protected outdoor access
Packaging: Export drum (recommended); suitable for small coils (if applicable)
Customization options: Sheath color, marking language, packaging marking, reel length scheme, documentation set, inspection support
Selection Guide
  1. Confirm line type and mechanical risk level (conduit, trench, corridor)
  2. Confirm Low Smoke Halogen-Free (LSZH) requirements and acceptance criteria in the project standard
  3. Confirm armor requirements (Type 23 steel tape) and any other line tests
  4. Select core count based on system design and neutral/PE scheme
  5. Select cross-sectional area based on current, distance, grouping, soil or conduit thermal conditions, and voltage drop limitations
  6. Determine preferred reel length to reduce joints and speed up installation
Quick Inquiry Template
Product: WDZ-YJY23
Voltage: 0.6/1 kV
Required Standards: __
Low Smoke Halogen-Free (LSZH) Requirements: __
Core Wire Configuration: __
Cross-sectional Area and Quantity: __
Total Length: __ meters
Line Type: Conduit/Trench/Utility Corridor/Protected Outdoor
Destination: Country and Port __
Trade Terms: __
Packaging: Reel
Preferred Reel Length: __
Required Documents: __
Remarks: Markup Language, Delivery Schedule, Inspection Requirements
Frequently Asked Questions
Q1 What is WDZ-YJY23 mainly used for?
A It is used for low-voltage fixed-installation feeders that require low smoke halogen-free (LSZH) performance and steel strip armor protection in conduits, trenches, and utility corridors.
Q2 What does "23" in the model number mean?
A "23" generally indicates a steel strip armor structure to improve its mechanical protection performance against pressure and impact.
Q3. How does it differ from unarmored low-smoke halogen-free cross-linked polyethylene (XLPE) power cables?
A. WDZ-YJY23 includes an armor layer for mechanical protection, making it more suitable for underground and high-risk lines than unarmored constructions.
Q4. What is the typical voltage of WDZ-YJY23?
A. It is typically supplied as a 0.6/1kV low-voltage armored power cable.
Q5. What are the commonly used specifications for underground feeders?
A. Cables from 10 to 50 mm² are widely used in building feeders, while cables from 70 to 240 mm² and above are used for higher loads and longer lines, depending on voltage drop limitations.
Q6. What information is needed for a quick quote?
A. Standard specifications, low-smoke halogen-free (LSZH) standard, number of conductors, specification list, line type, total meters, drum length requirements, destination, and required documentation.
Service of JinHong Company
Over Productions Service:

JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

Quality Certification Services:

JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

Profession Customer Service:

JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

Delivery And Shipping Services:

While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.