WDZN-YJY LSZH XLPE Fire Resistant Cable 0.6/1kV For Emergency Routes

WDZN-YJY LSZH XLPE Fire Resistant Cable 0.6/1kV For Emergency Routes

Brand Name: JinHong
Model Number: WDZN-YJY
MOQ: 100m
Price: 8.55-30 USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Installationmethod:
Underground, Overhead, Or Indoor
Conductormaterial:
Copper Or Aluminum
Voltagerating:
Up To 35kV
Sheathmaterial:
PVC, PE, Or LSZH
Cablediameter:
Varies Based On Specifications
Cabletype:
Armored Or Unarmored
Temperaturerange:
-40°C To 90°C
Application:
Power Distribution In Industrial Environments
Flameretardant:
Yes/No
Currentcapacity:
Depends On Cable Size And Type
Productname:
Industrial Power Cables
Numberofcores:
1 To 5 Cores
Insulationmaterial:
PVC, XLPE, Or Rubber
Standardscompliance:
IEC, BS, UL, Or IEEE
Shielding:
Optional Metallic Or Non-metallic Shield
Highlight:

WDZN-YJY LSZH XLPE Fire Resistant

,

LSZH XLPE Fire Resistant Cable

,

Emergency Routes XLPE Fire Resistant Cable

Product Description
WDZN-YJY Low Smoke Halogen-Free (LSZH) XLPE Insulated Copper Core Power Cable
Core Value

When you need low-smoke halogen-free (LSZH) performance to reduce smoke and corrosive gases, and to provide fire-resistant circuit integrity for critical low-voltage loads, choose WDZN-YJY.

Product Overview

WDZN-YJY is a low-voltage copper core power cable with XLPE insulation and an LSZH sheath system. Its manufacturing meets fire-resistant structural requirements and maintains electrical continuity in fire environments (test methods, categories, and durations depend on project-specific requirements). It is commonly used for emergency power feeders and critical service lines in enclosed or densely populated areas where visibility and reduction of corrosive gases are critical. Compared to standard YJY or YJV type cables, WDZN-YJY cables are ideal when the bill of quantities explicitly requires low smoke, halogen-free, and fire-resistant properties to ensure circuit integrity, especially in safety corridors and emergency systems.

Low Voltage Ratings
  • Typical Rated Voltage: 0.6/1 kV
  • Applications: Fixed low-voltage distribution feeders and emergency circuits
  • Project Notes: Please confirm the fire resistance rating/class and Low Smoke Halogen-Free (LSZH) acceptance criteria specified in the project specifications.
Applications of WDZN-YJY Typical Applications
  • Emergency lighting and evacuation guidance power supply lines
  • Fire alarm system power supply and critical control power supply
  • Smoke exhaust and booster fan power supply
  • Fire pump and critical machinery power supply
  • Public buildings, transportation hubs, hospitals, hotels, shopping malls, and high-traffic areas
  • Subway, railway, tunnel, and underground passage installations
  • Data center and critical service shafts requiring reduced smoke and circuit continuity
Typical Installation Routes
  • Cable trays, conduits, cable trays, risers, shafts, corridors, and guardrails
  • Fixed installation only
Why Buyers Choose WDZN-YJY
Low Smoke Halogen-Free (LSZH) performance ensures safer evacuation and less secondary corrosion

LSZH sheathed systems are designed to reduce smoke and prevent the generation of corrosive halogen gases, thereby improving visibility and reducing damage to electrical and metal infrastructure.

Fire-resistant circuit integrity for critical loads

Fire resistance refers to maintaining the electrical continuity of critical systems during a fire, according to specified test methods and durations.

XLPE Insulation Ensures Stable Low-Voltage Distribution Performance

XLPE provides reliable dielectric and thermal properties for continuous-load low-voltage feeders.

Highly Compliant with Public Infrastructure Project Requirements

Typically used in projects with stringent safety clauses and inspection requirements in tender documents.

Structure Overview
  • Conductor: Copper stranded wire
  • Insulation: XLPE
  • Fire Resistance: Circuit integrity designed according to specified standards and durations
  • Outer Sheath: LSZH (Low Smoke Halogen-Free)
  • Armor: None (unless otherwise specified)
  • Installation Types: Fixed installation, emergency, and critical lines
Process and Manufacturing Notes
  • Copper Conductor Stranding and Resistance Control
  • Conductor production meets stable resistance targets to ensure consistent and reliable performance and high termination reliability.
  • XLPE Insulation Extrusion and Crosslinking
  • The insulation layer is extruded and crosslinked to form a robust dielectric layer suitable for low-voltage operation.
  • Fire-Resistant Structure Integration
  • Fire barriers or fire-resistant design elements are used to ensure circuit continuity under the fire-resistant testing conditions specified in project standards.
  • Core Identification and Assembly
  • The core is identified and assembled into a stable geometry to improve drawability and sheath uniformity.
  • Low-Smoke Halogen-Free Sheath and Marking
  • A low-smoke halogen-free sheath compound is applied to meet low-smoke halogen-free targets, and marking is performed for easy traceability.
  • Routine Inspections
  • Typical inspections include conductor resistance, insulation thickness, spark testing, voltage testing, dimensional inspection, sheath integrity, and fire resistance verification according to the specified category.
General Specifications Overview Common Core Wire Configurations (Depending on Project)
  • 1C for Dedicated Emergency Feeders
  • 2C for Single-Phase Safety Circuits
  • 3C for Three-Phase Circuits Without Neutral (Depending on Design)
  • 4C for Three-Phase Distribution with Neutral
  • 5C for Three-Phase Distribution with Neutral and Protective Equipment (PE) (Depending on Design)

Based on design practice, 3+1 and 3+2 feeder structures can be used.

Common Cross-Sectional Areas (mm²)
  • 1.5
  • 2.5
  • 4
  • 6
  • 10
  • 16
  • 25
  • 35
  • 50
  • 70
  • 95
  • 120
  • 150
  • 185
  • 240
  • 300
High-Frequency Combination Specifications
  • 2C x 1.5
  • 2C x 2.5
  • 2C x 4
  • 3C x 2.5
  • 3C x 4
  • 3C x 6
  • 4C x 10
  • 4C x 16
  • 4C x 25
  • 4C x 35
  • 5C x 10
  • 5 cores x 16
  • 5 cores x 25
  • 1 core x 70
  • 1 core x 95
  • 1 core x 120
  • 1 core x 150
Specifications (can be copied directly)
Model: WDZN-YJY
Cable Type: Low Smoke Halogen-Free Flame-Retardant Cross-Linked Polyethylene Insulated Copper Low-Voltage Power Cable
Rated Voltage: 0.6/1 kV
Conductor: Copper Stranded Wire
Insulation: Cross-Linked Polyethylene
Outer Sheath: Low Smoke Halogen-Free (LSZH)
Fire Resistance: Circuit Integrity under Fire Testing (Duration/Category as specified by the project)
Armor: None (Unarmored unless otherwise specified)
Core Options: 1 core 2 cores 3 cores 4 cores 5 cores 3+1 cores 3+2 cores (as required)
Common Size Range: 1.5 to 300 mm² (depending on core count and standard)
Typical Operating Current Performance: XLPE Designed for a maximum temperature resistance of 90°C (depending on standards).
Typical installations: Trays, conduits, risers, shafts, corridors, protection circuits for critical circuits.
Packaging: Small sizes are packaged in rolls; large sizes are packaged in export reels.
Optional configurations: Markup language, reel length diagram, packaging markings, documentation suite, inspection support.
Selection Guidelines

Select WDZN-YJY when emergency wiring and critical loads require Low Smoke Halogen-Free (LSZH) and fire-resistant circuit integrity.

Please confirm the following in the Bill of Materials (BOQ):

  • LSZH Performance Requirements
  • Fire resistance test methods, durations, and categories
  • Select the number of conductors based on the circuit design and neutral/protective layer (PE) scheme.
  • Select the conductor size based on current, line length, grouping, ambient temperature, and permissible voltage drop.
  • If the line is subject to underground mechanical risks or pressure, specify the armored LSZH fire-resistant model as needed.
Quick Inquiry Template
Product: WDZN-YJY
Voltage: 0.6/1 kV
Required Standards: __
Low Smoke Halogen-Free (LSZH) Requirements: __
Fire Resistance Requirements (Test Category and Duration): __
Core Wire Configuration: __
Cross-sectional Dimensions and Quantity: __
Total Length: __ meters
Installation Method: Tray/Conduit/Riser/Shaft/Corridor/Tunnel
Destination: Country and Port __
Trade Terms: __
Packaging: Roll/Reel
Preferred Reel Length: __
Required Documents: __
Remarks: Markup Language, Delivery Schedule, Inspection Requirements
Frequently Asked Questions
  • Question 1: What is the purpose of WDZN-YJY?

    Answer: WDZN-YJY is used for low-voltage fixed-installation circuits that require low smoke halogen-free (LSZH) performance and fire-resistant circuit integrity, such as critical systems like emergency lighting, smoke extraction, and fire pumps.

  • Q2 What does WDZN stand for?

    A: WDZ is typically associated with Low Smoke Halogen-Free (LSZH) sheathed systems, while N is generally used for fire-resistant circuit integrity requirements. Specific acceptance criteria must follow project standards.

  • Q3 What is the voltage of WDZN-YJY?

    A: It is typically supplied as a 0.6/1kV low-voltage power cable.

  • Q4 Is WDZN-YJY the same as flame-retardant cable?

    A: It is not just about flame retardancy. The goal of Low Smoke Halogen-Free (LSZH) cables is smoke-free and halogen-free, while the goal of fire-resistant cables is to maintain circuit integrity during fire exposure. Please confirm the required tests and durations in the Bill of Quantities (BOQ).

  • Q5 What are the most commonly used cable sizes in emergency projects?

    A: Cables from 1.5 to 10 mm² are typically used for emergency lighting and control power. Cables from 16 to 120 mm² and above are typically used for feeders to safety equipment, depending on the load and distance.

  • Q6 What details help expedite the quotation process?

    A. Standards, Low Smoke Halogen-Free (LSZH) requirements, fire resistance duration/category, core material configuration, size list, total meters, installation route, destination, packaging preferences, and documentation requirements.

Service of JinHong Company
  • Over Productions Service:

    JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

  • Quality Certification Services:

    JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

  • Profession Customer Service:

    JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

  • Delivery And Shipping Services:

    While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.