products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Low Voltage Cable
Created with Pixso.

Fire Resistant Cable WDZBN-YJY LSZH Low Voltage Aerial Bundled Cable

Fire Resistant Cable WDZBN-YJY LSZH Low Voltage Aerial Bundled Cable

Brand Name: JinHong
Model Number: WDZBN-YJY
MOQ: 100m
Price: 7.15-25 USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Temperaturerange:
-40°C To +90°C
Insulationmaterial:
XLPE (Cross-linked Polyethylene) Or PVC
Standardscompliance:
IEC, BS, UL, IEEE
Application:
Power Distribution In Industrial Plants, Factories, And Substations
Mechanicalprotection:
Steel Wire Armor Or Tape Armor
Numberofcores:
1 To 5 Cores
Installationenvironment:
Indoor And Outdoor Use
Sheathmaterial:
PVC, PE, Or LSZH
Maximumoperatingcurrent:
Depends On Cable Size, Typically Up To 1000A
Flameretardant:
Yes
Cabletype:
Armored Or Unarmored
Chemicalresistance:
Resistant To Oil, Chemicals, And Solvents
Conductormaterial:
Copper Or Aluminum
Voltagerating:
Up To 35kV
Productname:
Industrial Power Cables
Highlight:

Fire Resistant Cable WDZBN-YJY

,

LSZH Low Voltage Aerial Bundled Cable

,

WDZBN-YJY Low Voltage Aerial Bundled Cable

Product Description

WDZBN-YJY LSZH Fire-Resistant XLPE Cable 0.6/1kV for Safety Circuits

WDZBN-YJY Low-Smoke Halogen-Free (LSZH) XLPE Low-Voltage Power Cable

WDZBN-YJY is a low-smoke halogen-free (LSZH) XLPE low-voltage power cable suitable for 0.6/1kV low-voltage fixed installations, offering both flame-retardant properties and fire-resistant circuit integrity options (specific options depend on the standard). It is ideal for public buildings, tunnels, subways, hospitals, and emergency power lines.

Core Values

If your project requires reduced smoke and corrosive gases under fire conditions and enhanced circuit continuity for critical loads, choose WDZBN-YJY.

Product Overview

WDZBN-YJY is a low-voltage copper core power cable with an XLPE insulation and LSZH sheath system, typically specified for safety-critical buildings and infrastructure. In enclosed or densely populated areas, evacuation visibility and equipment protection are critical, therefore WDZBN-YJY is frequently included in the Bill of Quantities (BOQ). The “B" designation typically indicates the flame-retardant rating within this model series, while the “N" designation typically indicates the fire resistance requirements of the circuit during fire exposure. Specific performance characteristics must comply with relevant standards and the fire resistance test duration/rating specified in the project documents.

Low Voltage Ratings

  • Typical Rated Voltage: 0.6/1 kV
  • Applications: Fixed low-voltage distribution feeders and critical circuits
  • Project Notes: Please confirm the flame retardancy rating, Low Smoke Halogen-Free (LSZH) requirements, and fire resistance test duration/rating in the Bill of Quantities (BOQ).

Applications of WDZBN-YJY

Typical Applications

  • Emergency lighting and evacuation guidance power lines in public buildings
  • Fire alarm, smoke extraction, and critical service feeders in shafts and corridors
  • Metro, railway, station, tunnel, and underground utility corridors
  • Hospitals, airports, data centers, hotels, shopping malls, schools, and high-traffic areas
  • Critical power distribution lines with explicit requirements for smoke reduction and circuit integrity
  • Installation of indoor cable trays, conduits, risers, shafts, and protected wiring

Reasons Buyers Choose WDZBN-YJY

Low Smoke Halogen-Free (LSZH) performance ensures safer evacuation and lower corrosion risk

LSZH sheathing systems are designed to reduce smoke and prevent the generation of corrosive halogen gases, thus protecting people, equipment, and metal infrastructure in a fire.

Flame retardant rating controls cable routing

Flame retardant ratings are often required to limit the spread of flames along dense cable routes, such as shafts, corridors, and equipment rooms.

Fire-Resistant Circuit Integrity Options for Critical Loads

When projects require maintaining power continuity for critical systems in fire environments, the "N" requirement is typically used, but specified test methods and durations must be met.

XLPE Insulation Ensures Reliable Low-Voltage Distribution

XLPE insulation ensures stable electrical performance for feeders and continuous load low-voltage circuits.

Compliant Project Procurement Ready

A wide range of sizes, repeatable construction, and comprehensive documentation support bid compliance and phased EPC delivery.

Structural Overview

  • Conductor: Copper, stranded wire
  • Insulation: Cross-linked polyethylene (XLPE)
  • Sheath System: Low-smoke halogen-free (LSZH) outer sheath
  • Flame retardancy: Generally associated with Class "B" (subject to standards)
  • Fire resistance: Circuit integrity design element associated with Class "N" (subject to standards)
  • Armor: None (unarmored unless otherwise specified)
  • Installation type: Fixed installation in building and infrastructure wiring

Process and Manufacturing Notes

Copper conductor stranding and resistance control

The stranding method is carefully controlled to achieve stable resistance and consistent termination performance.

Cross-linked polyethylene (XLPE) insulation extrusion and cross-linking

The insulation layer is extruded and cross-linked to form a robust dielectric layer suitable for low-voltage distribution applications.

Fire-resistant component integration (if specified)

Fire barriers or fire-resistant layers are used to ensure circuit continuity under required fire resistance testing conditions (design and materials depend on reference standards and categories).

Core Identification and Wiring

Cores are identified and assembled using controlled geometry to improve roundness and ease of installation.

Low Smoke Halogen-Free (LSZH) Composite Material Preparation and Sheath Extrusion

Low smoke halogen-free (LSZH) composite materials are processed and extruded to meet low smoke halogen-free performance targets, with flame-retardant formulations conforming to the required category.

Routine Inspections

Typical inspections include conductor resistance, insulation thickness, spark testing, voltage testing, dimensional inspection, and sheath integrity verification. Fire resistance verification is performed according to specified standards and categories.

General Specifications Overview

Common Core Wire Configurations (Project-Specific)

  • 1C: For dedicated feeders and single-core cabling
  • 2C: For single-phase critical circuits
  • 3C: For three-phase circuits without a neutral (Design-Specific)
  • 4C: For three-phase distribution with a neutral conductor
  • 5C: For three-phase circuits with a neutral conductor and physical earth (PE) protection (Design-Specific)
  • 3+1 and 3+2 configurations may be available depending on local design specifications.

Common Cross-sectional Areas (mm²)

1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300

High-Frequency Project Combinations

  • 2C x 1.5 2C x 2.5 2C x 4
  • 3C x 2.5 3C x 4 3C x 6
  • 4C x 10 4C x 16 4C x 25 4C x 35 4C x 50
  • 5 cores x 10 5 cores x 16 5 cores x 25
  • 1 core x 70 1 core x 95 1 core x 120 1 core x 150

Specifications (can be copied directly)

Model WDZBN-YJY
Cable Type Low Smoke Halogen-Free Flame Retardant XLPE Insulated Copper Low Voltage Power Cable (Specific standards vary depending on the application)
Rated Voltage 0.6/1 kV
Conductor Copper Stranded Wire
Insulation XLPE
Outer Sheath Low Smoke Halogen-Free (LSZH)
Flame Retardant Rating Class B, usually associated with "B" (Specific standards vary depending on the application)
Fire Resistance Circuit integrity under fire testing, usually associated with "N" (Specific duration/category varies depending on the application)
Armor None (Unarmored unless otherwise specified)
Core Options 1 core 2 cores 3 cores 4 cores 5-core 3+1 or 3+2 (as required)
Common size range 1.5 to 300 mm² (depending on core count and standard)
Typical operating temperature XLPE design up to 90°C (depending on standard)
Typical installation methods Tray, conduit, riser, shaft, corridor, protection circuit for critical circuits
Packaging Small sizes are packaged in rolls; large sizes are packaged in export drums (depending on order)
Optional configurations Marking language, sheath color, packaging marking, drum length diagram, documentation suite, inspection support

Selection Guide

When you require a Low Smoke Halogen-Free (LSZH) flame retardant rating and fire-resistant circuit integrity requirements for critical loads, choose WDZBN-YJY.

Please confirm the following three key items in the Bill of Materials (BOQ):

  1. Low Smoke Halogen-Free (LSZH) performance requirements
  2. Flame retardancy rating (Class B or specifically specified)
  3. Fire resistance test method, duration, and rating (for Class "N" requirements)
  • Select the number of conductors based on the circuit design and neutral/protective earth (PE) configuration.
  • Select the cross-sectional area based on load current, line length, grouping method, ambient temperature, and permissible voltage drop.
  • If the line presents a high mechanical risk or is under underground pressure, specify armored low smoke halogen-free fire-resistant cable as required.

Quick Inquiry Template (Paste and Send)

Product WDZBN-YJY
Voltage 0.6/1 kV
Standard Requirements __
Low Smoke Halogen-Free (LSZH) Requirements __
Flame Retardant Rating __
Fire Resistance Requirements (Test Rating and Duration) __
Core Material Configuration __
Cross-sectional Dimensions and Quantity __
Total Length __ meters
Installation Method Tray/Conduit/Riser/Shaft/Corridor/Tunnel
Destination Country and Port: __
Trade Terms __
Packaging Roll/Panel
Preferred Panel Length __
Required Documents __
Remarks Markup Language, Delivery Schedule, Inspection Requirements

Frequently Asked Questions

Q1 What is WDZBN-YJY mainly used for?

A It is used for low-voltage fixed installation lines, especially suitable for applications requiring low-smoke halogen-free (LSZH) performance, flame retardancy rating, and fire-resistant circuit integrity for critical circuits.

Q2 What does WDZBN stand for?

A WDZ is typically used in LSZH sheathed systems. "B" usually indicates the flame retardancy rating, and "N" usually indicates the fire resistance requirement. Specific meanings and acceptance criteria must follow project standards.

Q3 What is the typical rated voltage?

A WDZBN-YJY is typically used for 0.6/1kV low-voltage distribution and critical circuits.

Q4 Is WDZBN-YJY the same as flame-retardant cable?

A It typically focuses on more than just flame retardancy: LSZH emphasizes smokeless and halogen-free performance, and "N" usually emphasizes circuit integrity under fire-resistant testing conditions (if specified).

Q5 What are the commonly used cable sizes in public building and infrastructure projects?

A: Emergency lighting and control power typically use 1.5 to 10 mm² cables, while distribution lines typically use 16 to 50 mm² cables. Fire pumps and critical feeders use larger cable sizes depending on the load and distance.

Q6 What details help expedite quoting and compliance matching?

A: Standards, Low Smoke Halogen-Free (LSZH) requirements, flame retardancy rating, fire resistance duration/rating, core configuration, size list, total meters, line type, destination, packaging preferences, and required documentation.

Service of JinHong Company

Over Productions Service:

JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

Quality Certification Services:

JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

Profession Customer Service:

JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

Delivery And Shipping Services:

While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.