products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Fire Resistant Cable
Created with Pixso.

ZR-YJV22 XLPE Armored Cable 12/20kV Fire Resistant Cable For Underground

ZR-YJV22 XLPE Armored Cable 12/20kV Fire Resistant Cable For Underground

Brand Name: JinHong
Model Number: ZR-YJV22
MOQ: 100m
Price: 10-15.25 USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Mechanicalprotection:
Steel Wire Armor Or Aluminum Tape Armor
Installationenvironment:
Underground, Indoor, Outdoor, Or Direct Burial
Sheathmaterial:
PVC, PE, Or LSZH
Cabletype:
Armored Or Unarmored
Productname:
Industrial Power Cables
Numberofcores:
1, 2, 3, Or More
Flameretardant:
Yes Or No
Voltagerating:
0.6/1kV, 3.6/6kV, 6/10kV, 12/20kV
Conductormaterial:
Copper Or Aluminum
Maximumoperatingvoltage:
Up To 35kV
Application:
Power Distribution In Industrial Plants
Currentrating:
Depends On Conductor Size And Insulation
Insulationmaterial:
PVC, XLPE, Or Rubber
Standardscompliance:
IEC, BS, UL, IEEE
Temperaturerange:
-40°C To +90°C
Highlight:

ZR-YJV22 XLPE Armored Cable

,

XLPE Armored Cable 12/20kV

,

12/20kV Fire Resistant Cable

Product Description

ZR-YJV22 Flame-Retardant Armored XLPE Power Cable 0.6/1kV for Underground

ZR-YJV22 is a low-voltage copper core power cable that combines flame-retardant properties with steel tape armor, providing enhanced mechanical protection in fixed installations. This cable is commonly used in lines requiring increased fire safety and protection against compression and external stresses, such as underground conduits, trenches, cable corridors, building inlets, and industrial distribution lines. The cable typically features copper conductors insulated with cross-linked polyethylene (XLPE) and an outer sheath system that meets the relevant standard flame-retardant rating requirements.

For cross-border sourcing, ZR-YJV22 is positioned as a practical "fire safety + line protection" low-voltage feeder cable suitable for contractors and EPC purchasers working on infrastructure, public building, and industrial site projects.

Rated Voltage

Typical rated voltage: 0.6/1 kV

Please confirm the flame-retardant rating required in your project standards and Bill of Quantities (BOQ).

General Specifications Overview
Common Core Wire Configurations
  • 1C for high-current feeders and phase-by-phase installations (depending on the project)
  • 2C for dedicated single-phase circuits
  • 3C for three-phase circuits without a neutral conductor (depending on the project)
  • 4C for three-phase distribution with a neutral conductor
  • 5C for three-phase distribution with a neutral conductor and physical earth (PE) protection (depending on the project)
  • 3+1 and 3+2 are used in many commonly used feeder configurations (depending on the project)
Common Cross-sectional Areas (mm²)

1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400

High-Frequency Armored Feeder Combinations
  • 4C x 10
  • 4C x 16
  • 4C x 25
  • 4C x 35
  • 4C x 50
  • 5C x 10
  • 5C x 16
  • 5C x 25
  • 5C x 35
  • 3 cores x 10
  • 3 cores x 16
  • 3 cores x 25
  • 1 core x 95
  • 1 core x 120
  • 1 core x 150
  • 1 core x 185
  • 1 core x 240

Suitable in 3+1 and 3+2 configurations according to local practice and Bill of Materials (BOQ).

Availability depends on conductor grade, armor construction, and required standards.

Reasons buyers choose ZR-YJV22:
  • Flame retardant rating ensures safer cable laying

    Designed to help limit the spread of flame along the cable laying path, thereby improving the safety of risers, corridors, and dense cable laying.

  • Steel tape armor provides mechanical protection

    The armor construction improves resistance to compression and external pressure, enhancing the reliability of underground conduits, trenches, and protected corridors.

  • XLPE Insulation Ensures Stable Low-Voltage Feeder Performance

    XLPE insulation provides reliable dielectric strength and thermal properties under continuous load.

  • A Balanced Solution for Infrastructure and Industrial Projects

    A viable upgrade option when standard unarmored flame-retardant cables fail to meet line conditions.

  • Easy for EPC Contractors

    Common sizes, standardized construction, and reel designs facilitate bill of materials matching, phased delivery, and predictable field installation planning.

Typical Applications
  • Underground power distribution in conduits and trenches
  • Building incoming lines and main low-voltage distribution lines
  • Cable corridors, utility passageways, and protected tunnels
  • Industrial sites with external pressure risks along cable lines
  • Fixed installations requiring flame retardant ratings and armor protection
Manufacturing and Process Description
  1. Copper Conductor Production

    Copper is drawn and stranded to the specified conductor grade to meet resistance targets and provide suitable installation flexibility.

  2. XLPE Insulation Extrusion and Crosslinking

    XLPE is extruded and crosslinked to form a stable low-voltage dielectric layer.

  3. Core Identification and Wiring

    Insulated cores are identified and laminated in a controlled geometry; fillers and adhesives are used to maintain roundness and dimensional stability.

  4. Side Layer Formation

    Side layers are laid to protect the cores and provide a smooth base for the armor layers.

  5. Steel Tape Armoring

    Steel tape is wound in a controlled overlap pattern, primarily providing mechanical protection against compression and external pressure.

  6. Flame-Retardant Outer Sheath Extrusion

    A sheath compound system that meets the required standard flame retardancy rating is selected, processed, and then extruded at a controlled thickness.

  7. Routine Testing and Compliance Checks

    Typical checks include conductor resistance, insulation thickness control, spark testing, voltage testing, dimensional verification, and sheath integrity checks. Flame retardancy verification is performed according to the required rating.

Structural Overview
Conductor:
Copper
Insulation:
Cross-linked Polyethylene (XLPE)
Armor:
Steel tape armor (22 structure, specific standard subject to change)
Outer Sheath:
Flame-retardant composite material (specific standard subject to change)
Installation Method:
Fixed, including underground conduits and protected wiring
Specifications
Attribute Detail
Model ZR-YJV22
Cable Category Flame-retardant armored XLPE power cable
Rated Voltage 0.6/1 kV
Conductor Copper stranded wire (grade subject to change)
Insulation Cross-linked Polyethylene (XLPE)
Armor Steel tape armor (22 structure)
Sheath Flame-retardant composite material
Core Configuration 1 core, 2 cores, 3 cores, 4 cores, 5 cores, 3+1, 3+2
Common Cross-sectional Area 1.5 to 400 mm²
Typical Maximum Operating Temperature Up to 90°C (XLPE) (Design, specific standards depend on the situation)
Typical installation methods duct, trench corridor, riser, protected fixed wiring
Packaging Most sizes are packaged in reels, smaller sizes in coils
Optional services Markup language, packaging marking, reel planning, documentation
Selection Guide
  1. When the project requires flame-retardant low-voltage feeder cable with steel tape armor protection for underground or mechanically sensitive lines, please select ZR-YJV22.
  2. Confirm the flame retardancy rating required by the reference standard.
  3. Select the number of cores based on the distribution scheme and neutral/protection layer requirements.
  4. Select the cross-sectional area based on current, line length, grouping, ambient temperature, and allowable voltage drop.
  5. If the line also requires low-smoke halogen-free, specify low-smoke halogen-free armored cable instead of the standard ZR sheath system.
Quick Inquiry Template
Product:
ZR-YJV22
Voltage:
0.6/1 kV
Flame Retardant Requirement:
Complies with Standard__
Core Wire Configuration:
__
Cross-section List:
__ mm²
Total Quantity:
__ meters
Installation Path:
Conduit/Trench/Corridor/Building Inlet
Required Standard:
__
Destination:
Country and Port__
Trade Terms:
__
Special Requirements:
Sheath Requirements, Markings, Reel Length, Inspection Documents
Frequently Asked Questions
What is ZR-YJV22 used for?
It is used for low-voltage power distribution lines that require a flame retardant rating and steel tape armor for line protection, commonly found in conduits, trenches, corridors, and building inlets.
What does 22 construction usually represent?
In many market practices, it indicates a steel tape armored construction designed to improve resistance to compression and external pressure; specific requirements are subject to reference standards.
What is the difference between ZR-YJV22 and ZR-YJV?
ZR-YJV22 features added steel tape armor for mechanical protection, while ZR-YJV is typically unarmored. Both meet the flame retardancy requirements of relevant standards.
Can ZR-YJV22 be used for direct burial?
It is typically used in conduits and trenches. The suitability for direct burial depends on soil conditions, mechanical risks, and local requirements. Please provide detailed installation route information for proper selection.
What sizes are commonly used by contractors?
10 to 50 mm² 4-core and 5-core cables are commonly used for building distribution, while 95 to 240 mm² 1-core cables are commonly used for high-current feeders.
What information is needed for a quote?
Flame retardancy rating, core configuration, cross-sectional area, total length, required standards, installation route, packaging requirements, and destination.
Service of JinHong Company
  • Over Productions Service:

    JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

  • Quality Certification Services:

    JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

  • Profession Customer Service:

    JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

  • Delivery And Shipping Services:

    While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.