products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Fire Resistant Cable
Created with Pixso.

XLPE Copper Fire Rated Cable 500V NH-YJV 4 Cores 5 Cores Fire Proof Cable

XLPE Copper Fire Rated Cable 500V NH-YJV 4 Cores 5 Cores Fire Proof Cable

Brand Name: JinHong
Model Number: NH-YJV
MOQ: 100m
Price: 8.15-25 USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Color:
Orange
Package:
305mt/roll
Shield:
PET / AL-Foil
Productname:
Fire Resistant Cable
Rate Voltage:
0.6/1 KV
Model:
FRC Cable
Conductor:
Strand Bear Copper
Sample:
Optional
Core:
4
Fire Barrier:
Mica Fiber Tape
Material Shape:
Flat Wire
Light Duty:
500V
Core No:
Five
Voltage Rating:
600V/1000V/2000V/3500V
Highlight:

XLPE Copper Fire Rated Cable

,

Fire Rated Cable 500V NH-YJV

,

5 Cores Fire Proof Cable

Product Description

NH-YJV Fire-Resistant XLPE Copper Power Cable for Emergency Feeders

NH-YJV is a fire-resistant low-voltage copper core power cable designed for emergency feeders and critical distribution lines that, according to relevant standards, must remain energized for a period of time under fire conditions. It features cross-linked polyethylene (XLPE) insulation to ensure stable thermal and electrical performance, and a dedicated fire-resistant layer to help maintain circuit integrity in fire environments. NH-YJV is widely used in high-density buildings, transportation facilities, industrial parks, and infrastructure projects where continuous power supply is required to ensure evacuation, fire protection, and life-saving services.

For cross-border sourcing, NH-YJV can serve as a compliant cable for emergency distribution, meeting the project's requirements for both XLPE insulation and fire resistance in standardized feeder solutions.

Rated Voltage

Typical rated voltage: 0.6/1 kV

Please confirm the exact rated voltage and required fire resistance duration/class listed in your Bill of Materials (BOQ).

General Specifications Overview
Common Core Wire Configurations
  • 1C for high-current feeders and phase-separated wiring
  • 2C for dedicated single-phase emergency loads
  • 3C for three-phase loads without a neutral wire (depending on the project)
  • 4C for three-phase distribution with a neutral wire
  • 5C for three-phase distribution with a neutral wire and PE (depending on the project)
  • 3+1 and 3+2 are used in feeder configurations used in many building standards (depending on the project)
Common Cross-sectional Areas (mm²)
  • 1.5
  • 2.5
  • 4
  • 6
  • 10
  • 16
  • 25
  • 35
  • 50
  • 70
  • 95
  • 120
  • 150
  • 185
  • 240
  • 300
  • 400
Quick-Move Emergency Feeder Bundles
  • 4C x 10
  • 4C x 16
  • 4C x 25
  • 4C x 35
  • 4C x 50
  • 5C x 10
  • 5C x 16
  • 5C x 25
  • 3C x 10
  • 3C x 16
  • 3C x 25
  • 1C x 95
  • 1C x 120
  • 1C x 150
  • 1C x 185
  • 2C x 4
  • 2C x 6, suitable for common single-phase emergency circuits

Final supply depends on conductor grade and fire-resistant construction required by specified standards.

Applications
  • Emergency lighting feeders and critical switchboards
  • Fire pump power feeders and critical pump room circuits
  • Smoke exhaust and stairwell booster fan feeders
  • Emergency ventilation and critical HVAC power lines
  • Critical services for transportation facilities and public infrastructure (depending on the project)
  • Critical circuits requiring design continuity in data centers and equipment rooms
Advantages of NH-YJV
  • Ensuring circuit integrity for life-saving power supplies
    Fire-resistant construction helps maintain the operation of emergency feeders during a fire, thus supporting evacuation and firefighting operations.
  • XLPE Insulation Supports Higher Continuous Load Capacity
    XLPE insulation is widely used in low-voltage feeders due to its stable thermal properties during continuous operation and dense cable routing.
  • Clearer EPC Project Feeder Planning
    Standard core wire options and a universal size range simplify bill of materials matching, reduce substitution risks, and support repeated sourcing across multiple locations.
  • Reliable Operation Over Long Distances
    Suitable for main and branch feeders where voltage drop control and stable insulation performance are critical for system reliability.
  • Optimized Project Delivery
    Reel packaging, controllable reel lengths, and project marking support phased deployment, pull planning, and field installation arrangements.
Manufacturing and Process Specifications
  1. Conductor Production
    High-purity copper is drawn and stranded to the specified conductor grade to meet resistance targets and facilitate bending during wiring installation.
  2. Fire-Resistant Layer Integration
    A dedicated fire-resistant layer is applied according to relevant standards. This layer is a critical structural element for maintaining circuit integrity in the event of a fire.
  3. XLPE Insulation Extrusion and Crosslinking
    XLPE is extruded and crosslinked around the conductor to form a stable dielectric layer suitable for low-voltage feeder applications.
  4. Core Identification and Routing
    After identification, the insulated cores are stranded according to the required core structure, with strand length and filler controlled to maintain roundness and dimensional stability.
  5. Sheath and Surface Finishing
    The outer sheath protects the cable structure and enhances the durability of fixed installations. Final marking ensures traceability and facilitates project management.
  6. Routine Testing and Compliance Release
    Typical checks include conductor resistance, insulation thickness control, spark testing, voltage testing, dimensional verification, continuity testing, and fire resistance verification according to specified ratings.
Structural Overview
  • Conductor: Copper
  • Fire Resistance: Fire-resistant layer (depending on standard)
  • Insulation: Cross-linked polyethylene (XLPE)
  • Outer Sheath: Specified according to project requirements (typically polyvinyl chloride (PVC), or low smoke halogen-free (LSZH) according to project requirements)
  • Application: Fire-resistant low-voltage power supply feeder for emergency circuits
Specifications
Attribute Detail
Model NH-YJV
Cable Type Fire-resistant cross-linked polyethylene (XLPE) power cable
Rated Voltage 0.6/1 kV
Conductor Copper stranded wire (grade conforms to standard)
Fire Resistance According to required standard and duration
Insulation Cross-linked polyethylene (XLPE)
Sheath Specified according to project requirements (typically polyvinyl chloride (PVC), low smoke halogen-free (LSZH) optional)
Core Configuration Single core, double core, triple core, quadruple core, five core, 3+1, 3+2
Common Cross-sectional Area 1.5 to 400 mm²
Typical Maximum Operating Temperature Maximum 90°C (XLPE design, standard) (subject to availability)
Installation methods Tray, conduit, cable tray, riser, shaft, protective fixed wiring
Packaging Small sizes are packaged in rolls; medium and large sizes are packaged in spools.
Optional services Custom marking, packaging marking, spool planning, documentation kit
Selection Guide
  • If your project requires fire-resistant low-voltage feeders to ensure emergency load power supply during a fire, please select NH-YJV.
  • Please confirm the fire resistance duration/rating and acceptance testing methods required in the Bill of Quantities (BOQ).
  • Select the number of conductors based on the distribution scheme and neutral/protective electrical (PE) requirements.
  • Select the size based on current, distance, ambient temperature, cable grouping, and permissible voltage drop.
  • If the wiring includes underground or high-risk mechanical sections, please specify whether an armored fire-resistant version is required.
Quick Inquiry Text
  • Product: NH-YJV
  • Voltage: 0.6/1 kV
  • Fire Resistance Requirements and Duration: __
  • Core Wire Configuration: __
  • Cross-sectional Area: __ mm²
  • Total Quantity: __ meters
  • Installation Method: Cable Tray/Conduit/Cable Tray/Riser/Shaft
  • Required Standards: __
  • Destination: Country and Port __
  • Trade Terms: __
  • Special Requirements: Sheath Type, Marking, Reel Length, Inspection Documents
Frequently Asked Questions
What is the purpose of NH-YJV?
NH-YJV is used for emergency low-voltage feeders designed to maintain operation during fires, such as emergency lighting, fire pumps, smoke extraction systems, and critical business feeders.
What does NH mean in many specifications?
NH generally indicates a fire-resistant cable structure designed to maintain circuit integrity during fires. Its exact duration and testing methods are specified by reference standards.
How does NH-YJV differ from standard YJV?
NH-YJV includes a fire-resistant element designed to ensure circuit integrity in fire conditions, while standard YJV does not.
What are the most common specifications for emergency feeders?
4-core and 5-core feeders of 10 to 50 mm² are common, while single-core feeders of 95 to 240 mm² are often used for high-current emergency feeders, depending on the project load.
Which sheath should I choose, PVC or LSZH?
Please refer to the Bill of Quantities (BOQ). PVC sheathing is common in many buildings, while LSZH sheathing may be required for public buildings or enclosed circuits. Please specify your specific requirements in your Request for Quotation (RFQ) for an accurate match.
What information is needed for an accurate quote?
Fire resistance requirements and duration, rated voltage, core configuration, cross-sectional area, total length, required standards, packaging preferences, and destination.
Service of JinHong Company
  • Over Productions Service:
    JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.
  • Quality Certification Services:
    JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.
  • Profession Customer Service:
    JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.
  • Delivery And Shipping Services:
    While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.
Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.