3.6/6kV 6/10kV XLPE Flame Retardant Cable NH-YJV For Emergency Feeders
Product Summary
Product Details
6/10kV XLPE Flame Retardant Cable
,3.6/6kV XLPE Flame Retardant Cable
,Emergency Feeders fire rated cable
Product Description
NH-YJV Fire Resistant XLPE Power Cable 0.6/1kV for Emergency Feeders
NH-YJV is a fire-resistant low-voltage cross-linked polyethylene (XLPE) power cable designed to maintain circuit integrity and operate continuously for a period of time during fire exposure, in accordance with applicable standards. It is typically used in emergency and life-safety power circuits to ensure power continuity for evacuation and firefighting operations. NH-YJV features copper conductors, XLPE insulation, and integrated fire-resistant elements in its construction, making it suitable for critical feeders powering emergency lighting, fire pumps, smoke exhaust fans, booster systems, and important switchboards.
For cross-border sourcing, NH-YJV is an ideal choice for projects requiring fire-resistant XLPE insulated power cables, offering compliance, superior performance, and ease of installation in building and infrastructure wiring.
Typical rated voltage: 0.6/1 kV
Please confirm the required rated voltage, fire resistance rating, and duration in your Bill of Quantities (BOQ) and project standards.
- Emergency lighting main and branch feeders
- Fire pump power circuits
- Smoke exhaust and booster fan feeders
- Emergency ventilation and critical HVAC power supplies
- Critical switchboards and life safety switchboards
- Critical loads in tunnels, stations, airports, and high-rise buildings (depending on the project)
- Fixed installation in cable trays, conduits, cable trays, risers, shafts, equipment rooms, and protected indoor routes. For routes with high mechanical loads, please specify whether armoring is required.
- 1C for high-current feeders and phase-separated wiring
- 2C for dedicated single-phase emergency loads
- 3C for three-phase without neutral (project-specific)
- 4C for three-phase with neutral (common)
- 5C for three-phase with neutral and PE (common)
- 3+1 and 3+2 for feeder designs common in many markets (project-specific)
- 1.5
- 2.5
- 4
- 6
- 10
- 16
- 25
- 35
- 50
- 70
- 95
- 120
- 150
- 185
- 240
- 300
- 400
- 4C x 10
- 4C x 16
- 4C x 25
- 4C x 35
- 5C x 10
- 5C x 16
- 5C x 25
- 3C x 10
- 3C x 16
- 3C x 25
- 1C x 95
- 1C x 120
- 1C x 150
- 1C x 185
- 2C x 4
- 2C x 6, suitable for single-phase emergency lines
Availability depends on conductor grade and fire-resistant construction requirements of relevant standards.
-
Fire-resistant continuity, ensuring life safetyDesigned to keep emergency power circuits operational for a period of time during a fire, supporting evacuation systems and fire-fighting equipment.
-
XLPE insulation, superior thermal performanceXLPE insulation core material has stable dielectric and thermal properties, making NH-YJV suitable for emergency feeders with continuous load requirements.
-
Compliance Requirements for Public and Enclosed FacilitiesCommonly used in hospitals, shopping malls, high-rise buildings, stations, and infrastructure projects where emergency feeders must remain operational in the event of a fire.
-
Efficient EPC Procurement and Repeatable Bills of QuantitiesUniversal feeder sizes and repeatable construction support standardized procurement and phased delivery.
-
Easy Installation and TerminationThe YJV type construction supports easy termination and routing planning in typical building power distribution environments.
-
Copper Conductor PreparationCopper is drawn and stranded to meet resistance requirements and installation flexibility objectives.
-
Fire-Resistant Component IntegrationSpecial fire-resistant layers are applied according to required standards to ensure circuit integrity in a fire.
-
XLPE Insulation Extrusion and CrosslinkingXLPE insulation is extruded and crosslinked to form a robust dielectric layer suitable for low-voltage feeders.
-
Cable and Core AssemblyFor multi-core designs, insulated cores are stranded with a controlled pitch; fillers and adhesives can be used to stabilize the geometry.
-
Sheath Extrusion and FinishingAn outer sheath is applied to provide mechanical protection and improve installation durability, followed by marking and packaging controls for project delivery.
-
Routine Testing and Compliance ChecksTypical checks include conductor resistance, insulation thickness control, spark testing, voltage testing, dimensional verification, and continuity checks. Fire resistance verification is performed according to the required rating.
- Conductor:
- Copper
- Fire Resistance:
- Fire-resistant layer (as per standard design)
- Insulation:
- Cross-linked polyethylene (XLPE)
- Outer Sheath:
- Polyvinyl chloride (PVC) or specified sheath system (depending on tender requirements)
- Applications:
- Fire-resistant low-voltage power feeders and emergency distribution circuits
- Model:
- NH-YJV
- Cable Category:
- Fire-resistant cross-linked polyethylene (XLPE) power cable
- Rated Voltage:
- 0.6/1 kV
- Conductor:
- Copper stranded wire (as per standard classification)
- Fire Resistance:
- As required standard and duration
- Insulation:
- Cross-linked polyethylene (XLPE)
- Sheath:
- As specified in the standard or Bill of Quantities (BOQ) (often PVC))
- Core Options:
- Single core, double core, triple core, four cores, five cores, three-core single core, three-core double core
- Common Size Range:
- 1.5 mm² to 400 mm²
- Typical Installation Methods:
- Cable trays, conduits, trunking, risers, shafts, indoor protective wiring
- Packaging:
- Smaller sizes are packaged in rolls; medium and large sizes are packaged in reels.
- Customization Options:
- Marking language, packaging markings, reel length, document kit
- When a project requires fire-resistant low-voltage cross-linked polyethylene (XLPE) power cables to ensure the emergency feeder operates normally during a fire, select NH-YJV.
- Confirm the fire resistance duration and reference standards to avoid incorrect replacement.
- Select the number of cores based on system design and neutral/PE resistance requirements.
- Select the cross-sectional area based on load current, line length, ambient temperature, grouping, and allowable voltage drop.
- If the line is underground or has high mechanical requirements, specify whether armored fire-resistant cables are required.
- Product:
- NH-YJV
- Rated Voltage:
- 0.6/1 kV
- Fire Resistance Requirements and Duration:
- __
- Core Wire Configuration:
- __
- Cross-sectional Area:
- __ mm²
- Total Quantity:
- __ meters
- Installation Method:
- Cable Tray/Conduit/Cable Tray/Riser/Shaft
- Required Standards:
- __
- Destination:
- Country and Port __
- Trade Terms:
- __
- Special Requirements:
- Sheath Requirements, Markings, Reel Length, Inspection Documents
-
What are the main uses of NH-YJV?
NH-YJV is used for emergency low-voltage feeders that must remain operational during a fire, such as emergency lighting, fire pumps, and smoke extraction systems. Specific applications must comply with project standards.
-
What does NH usually represent?
NH usually indicates fire-resistant construction, designed to maintain circuit integrity during a fire. Specific testing methods and durations are specified by relevant standards.
-
How does NH-YJV differ from standard YJV?
NH-YJV includes a fire-resistant element designed to maintain circuit integrity in fire conditions, while standard YJV does not.
-
Is NH-YJV suitable for high-current feeders?
Yes. It is typically used for emergency feeders. The final size selection should be based on load current, line length, grouping method, and permissible voltage drop.
-
Does NH-YJV always use a PVC sheath?
The sheath type depends on standards and tender requirements. Many projects use PVC sheaths, while some specify the use of low-smoke halogen-free systems. Please follow the requirements of the Bill of Quantities (BOQ).
-
What information is needed for an accurate quote?
Fire resistance requirements and duration, rated voltage, core configuration, cross-section, total length, required standards, packaging preferences, and destination.
-
Over Productions Service:JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.
-
Quality Certification Services:JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.
-
Profession Customer Service:JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.
-
Delivery And Shipping Services:While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.
JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.