WDZ-YJY23 LSZH XLPE Steel Tape Armored Cable 0.6/1kV for Underground
WDZ-YJY23 is a low-voltage power cable designed for projects requiring Low Smoke Halogen-Free (LSZH) fire resistance and armored mechanical protection for underground or high-risk lines. It features copper conductors and cross-linked polyethylene (XLPE) insulation, armored with steel tape, and an outer sheath utilizing an LSZH system to reduce smoke concentration and corrosive gas release in the event of a fire. This cable is commonly used in underground conduits, trenches, cable corridors, and building inlets, particularly suitable for lines facing compression risks, backfill pressure, or high installation stress.
For cross-border sourcing, WDZ-YJY23 is positioned as a high-end "safety + protection" low-voltage cable suitable for infrastructure, public buildings, and industrial projects with specific requirements for LSZH compliance and armor durability.
Typical Rated Voltage: 0.6/1kV
Please confirm the rated voltage and required LSZH/flame retardant testing rating based on your project standards and Bill of Quantities (BOQ).
1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400
Supply availability varies depending on standards, sheath design, and low-smoke halogen-free composite system. Please confirm the specific structure to ensure compliance with tender requirements.
Low Smoke Halogen-Free Sheath Systems are designed to reduce smoke concentration and corrosive gases during fires, thereby improving evacuation visibility and reducing equipment corrosion damage.
Steel tape armor enhances resistance to external pressure and compression, thereby increasing the reliability of conduits, trenches, and protected underground passages.
XLPE insulation provides reliable electrical and thermal performance under continuous load, suitable for building and industrial feeders.
WDZ-YJY23 is ideal when standard low-smoke halogen-free (LSZH) cables are insufficient and armored protection is required without opting for a heavier protection design.
Universal configuration, predictable reel scheduling, and scalable supply make it suitable for phased deliveries and large bills of quantities (BOQs).
Typical inspection items include conductor resistance, insulation thickness, spark testing, voltage testing, dimensional verification, and sheath integrity inspection. Relevant documentation can be provided upon project request.
| Item | Value |
|---|---|
| Cable type | WDZ-YJY23 |
| Rated voltage | 0.6/1kV |
| Conductor material | Copper |
| Insulation material | Cross-linked polyethylene (XLPE) |
| Armor type | Steel tape armor (23 construction, depending on the standard) |
| Outer sheath | Low smoke halogen-free (LSZH) |
| Core configurations | 1C / 2C / 3C / 4C / 5C / 3+1 / 3+2 |
| Common cross-section range | 1.5 mm2 to 400 mm2 (market-common), larger sizes by request |
| Typical max operating temperature | up to 90 C (typical XLPE design, confirm per specification) |
| Installation routes | duct, trench, underground corridor, protected fixed routes |
| Packaging | drums for most sizes, export packing available |
What is WDZ-YJY23 used for
It is used for LV distribution routes that require LSZH fire-safety performance and steel tape armor protection, commonly in underground ducts, trenches, and protected corridors.
What does the “23" structure provide
It commonly refers to a steel tape armored construction in many markets, improving resistance to external pressure and compression in underground routes, subject to the referenced standard.
Why choose LSZH for underground building feeders
LSZH systems reduce smoke and corrosive gas generation in fire scenarios, support safer evacuation in buildings and reduce corrosion damage to equipment, especially in enclosed routes.
Can WDZ-YJY23 be used in direct burial
It is widely used in ducts and trenches. Direct burial suitability depends on soil condition, mechanical risk, and local requirements. Provide