WDZ-YJY Low Smoke Zero Halogen Cable 3.6/6kV 6/10kV 12/20kV Multicore Cable

WDZ-YJY Low Smoke Zero Halogen Cable 3.6/6kV 6/10kV 12/20kV Multicore Cable

Brand Name: JinHong
Model Number: WDZ-YJY
MOQ: 100m
Price: 10-15.55 USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Cabletype:
Single Core, Multicore, Flat Cable
Armortype:
Steel Wire Armor (SWA), Steel Tape Armor (STA), Non-armored
Flameretardant:
Yes/No
Temperaturerange:
-40°C To +90°C
Application:
Power Distribution In Industrial Plants, Mining, Construction
Cablestandards:
IEC, BS, UL, IEEE
Conductormaterial:
Copper Or Aluminum
Sheathmaterial:
PVC, PE, LSZH
Productname:
Industrial Power Cables
Maximumoperatingvoltage:
Up To 35kV
Voltagerating:
0.6/1kV, 3.6/6kV, 6/10kV, 12/20kV
Insulationmaterial:
PVC, XLPE, EPR
Oilresistance:
Yes/No
Numberofcores:
1 To 5 Cores
Highlight:

WDZ-YJY Low Smoke Zero Halogen Cable

,

12/20kV Multicore Cable

,

6/10kV Multicore Cable

Product Description

WDZ-YJY LSZH XLPE Power Cable 0.6/1kV for Safer Building Distribution

WDZ-YJY Low-Voltage Power Cable

WDZ-YJY is a low-voltage power cable specifically designed for indoor power distribution. Its low-smoke halogen-free (LSZH) performance effectively enhances fire safety. This cable features copper conductors, cross-linked polyethylene (XLPE) insulation, and a low-smoke halogen-free outer sheath system, suitable for installation in risers, shafts, corridors, equipment rooms, and high-density cable trays. WDZ-YJY is commonly used in commercial buildings, public facilities, transportation infrastructure support areas, and industrial buildings where strict requirements exist for reducing smoke concentration and corrosive gas emissions during fires.

For cross-border procurement, WDZ-YJY is a compliant low-voltage cable suitable for projects seeking a low-smoke halogen-free (LSZH) solution without additional armoring, balancing safety and installation efficiency.

Rated Voltage

Typical Rated Voltage: 0.6/1kV

Please confirm the rated voltage and required LSZH and flame retardant testing ratings according to your project standards.

Common Specifications Overview

Common Core Wire Configurations

  • 1C: Single-core feeder, phase separation, high current path
  • 2C: Dedicated single-phase circuit
  • 3C: Three-phase without neutral (depending on the project)
  • 4C: Three-phase with neutral (widely used)
  • 5C: Three-phase with neutral + protection circuit (widely used)
  • 3+1, 3+2: Common feeder structures in many markets

Common Cross-sectional Areas (mm²)

  • 1.5, 2.5, 4, 6, 10, 16, 25, 35, 50, 70, 95, 120, 150, 185, 240, 300, 400

Rapidly Changing Project Specifications

  • 3C x 4, 3C x 6, 3C x 10, 3C x 16
  • 4C x 6, 4C x 10, 4C x 16, 4C x 25, 4 cores x 35, 4 cores x 50
  • 5-core x 6, 5-core x 10, 5-core x 16, 5-core x 25
  • 1-core x 70, 1-core x 95, 1-core x 120, 1-core x 150, 1-core x 185, 1-core x 240

Actual supply varies depending on required standards, conductor grades, and Low Smoke Halogen-Free (LSZH) composite systems. Please confirm the specific construction to ensure compliance with tender requirements.

Reasons the Buyer Chooses WDZ-YJY

  • Low Smoke Halogen-Free Sheath, Creating a Cleaner Evacuation Environment Using a low smoke halogen-free cable system reduces smoke concentration and corrosive gases during a fire, thereby improving evacuation visibility and reducing equipment corrosion damage.
  • Cross-linked Polyethylene (XLPE) Insulation, Ensuring Stable Thermal Performance The cross-linked polyethylene (XLPE) insulation provides reliable low-voltage distribution under continuous load, making it suitable for building feeders and distribution circuits.
  • Practical installation suitable for cable trays, risers, and conduits. The unarmored construction provides sufficient flexibility for common building wiring routes while maintaining a robust insulation and sheathing system.
  • Ideal for public buildings and projects with high compliance requirements. Commonly used in hospitals, schools, shopping malls, stadiums, transportation infrastructure areas, and high-rise buildings where regulations explicitly specify Low Smoke Halogen-Free (LSZH) requirements.
  • Easy to procure, suitable for EPC and phased delivery. Universal configurations and reel designs facilitate Bill of Materials (BOQ) matching, repeat orders, and on-time delivery.

Typical Applications

  • Main low-voltage feeders and branch feeders within buildings
  • Cable trays, risers, shafts, corridors, and equipment rooms
  • Switchgear, distribution panels, and service lines
  • Commercial, residential high-rise buildings, and public utilities
  • Industrial buildings requiring indoor wiring to meet Low Smoke Halogen-Free (LSZH) requirements

Process and Manufacturing Notes

  1. Copper Conductor Production Copper is drawn and stranded into specified conductor grades to achieve stable resistance and suitable installation flexibility.
  2. XLPE Insulation Extrusion and Crosslinking The insulation layer is extruded and crosslinked to form a stable electrical layer suitable for low-voltage distribution applications.
  3. Core Identification and Wiring Cores are color-coded or numbered and stranded in specified numbers, with filler and binding tape added where necessary to ensure stable cable geometry.
  4. LSZH Sheath Composite and Extrusion Extruded low-smoke halogen-free sheath composite systems provide line protection and specific fire resistance.
  5. Routine Testing and Inspection Typical inspections include conductor resistance, insulation thickness, spark testing, voltage testing, and dimensional verification. Relevant documents can be provided according to project requirements.

Structure

Conductor:
Copper
Insulation:
Cross-linked polyethylene (XLPE)
Outer sheath:
Low smoke halogen-free (LSZH) composite system
Installation method:
Fixed installation in cable trays, conduits, cable trays, risers, and indoor protective circuits

Specifications

Item Value
Cable type WDZ-YJY
Rated voltage 0.6/1kV
Conductor material Copper
Insulation material Cross-linked polyethylene (XLPE)
Outer sheath Low smoke halogen-free (LSZH)
Core configuration 1 core/2 core/3 core/4 core/5 core/3+1 core/3+2 core
Common cross-sectional area range 1.5 mm² to 400 mm² (commonly used in the market), larger sizes can be customized upon request
Typical maximum operating temperature Up to 90°C (typical XLPE) (Design details subject to specifications)
Installation Path Trays, Cable Trays, Conduits, Riser Pipes, Shafts, Indoor Protective Paths
Packaging Small sizes are packaged in rolls; medium and large sizes are packaged in drums. Export packaging is available.

Selection Guide

  • When your project requires low-smoke halogen-free low-voltage power, please select WDZ-YJY.
  • Suitable for indoor building power distribution circuits, featuring a practical, unarmored structure.
  • Select the number of cores based on the requirements of the neutral and protective earth (PE) conductors, and choose the cross-sectional area based on current, line length, wiring configuration, ambient temperature, and permissible voltage drop.
  • For underground installations or environments with high mechanical risks, consider using armored low-smoke halogen-free (LSZH) cables. For outdoor environments, select a suitable sheathing system based on UV radiation and environmental conditions.

Quick Inquiry Template

Product: WDZ-YJY

Rated Voltage: 0.6/1kV

Core Configuration: __

Cross-sectional Area: __ mm²

Structure: __ cores x __ mm² (or 3+1 / 3+2)

Quantity: __ meters

Installation Method: Cable tray/conduit/cable tray/riser

Required Standard: __

Destination: Country and Port

Trade Terms: FOB / CIF / Other

Special Requirements: Low smoke halogen-free performance rating, printing, reel length, inspection documents, marking

Frequently Asked Questions

  • Applications of WDZ-YJY WDZ-YJY is used for indoor low-voltage power distribution, suitable for applications requiring low smoke halogen-free performance, including feeders and sub-feeders installed in cable trays, risers, shafts, and protected wiring.
  • Why does the project specify the use of low smoke halogen-free cable? Low-smoke halogen-free systems reduce smoke concentration and the generation of corrosive gases during a fire, thereby improving evacuation visibility and reducing corrosive damage to electrical equipment.
  • Is WDZ-YJY the same as PVC-sheathed XLPE power cable? No. WDZ-YJY typically uses a low-smoke halogen-free sheath compound system instead of standard PVC, designed to improve fire resistance in enclosed wiring.
  • Can WDZ-YJY be used outdoors? Outdoor suitability depends on the sheath compound and environmental exposure. If long-term exposure to UV, humidity, or harsh weather conditions is anticipated, please specify the specific conditions for proper matching.
  • What information is needed for an accurate quote? Core configuration, cross-section list, total length, required standards, installation route, packaging preferences, and destination.
  • Can you provide export packaging and project documentation? Yes. We can provide packaging markings, batch traceability information, routine test records, and export packaging for EPC and distributor sourcing.

Service of JinHong Company

  • Over Productions Service: JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.
  • Quality Certification Services: JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.
  • Profession Customer Service: JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.
  • Delivery And Shipping Services: While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.