products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Low Smoke Zero Halogen Cable
Created with Pixso.

WDZ-KYJRP Low Smoke Zero Halogen Cable LSZH Shielded Control Cable

WDZ-KYJRP Low Smoke Zero Halogen Cable LSZH Shielded Control Cable

Brand Name: JinHong
Model Number: WDZ-KYJRP
MOQ: 100m
Price: 12.15-20 USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Cable Construction:
Single Core Or Multi-core
Sheath Material:
PVC, PE, LSZH
Flame Retardant:
Yes/No
Application:
Industrial Power Distribution, Machinery, And Equipment
Chemical Resistance:
Oil, Acid, Alkali Resistant
Standards Compliance:
IEC, BS, UL, IEEE
Conductor Material:
Copper Or Aluminum
Installation Environment:
Indoor, Outdoor, Underground, Direct Burial
Insulation Material:
PVC, XLPE, EPR
Bending Radius:
10 To 20 Times Cable Diameter
Armor Type:
Steel Wire Armor (SWA), Steel Tape Armor (STA), Non-armored
Voltage Rating:
0.6/1 KV To 33 KV
Temperature Range:
-40°C To +90°C
Highlight:

WDZ-KYJRP Low Smoke Zero Halogen Cable

,

LSZH Shielded Control Cable

,

WDZ-KYJRP Shielded Control Cable

Product Description
WDZ-KYJRP: Low-Smoke Halogen-Free Shielded Control and Signal Cable

WDZ-KYJRP is a low-smoke halogen-free (LSZH) shielded control and signal cable designed for safety-critical buildings and industrial environments that require both clean evacuation environments and stable signal transmission. It is commonly used for instrumentation circuits, control lines, automation signals, sensor connections, and low-voltage communication circuits in cable trays, conduits, and control cabinets. The shielding is designed to reduce electromagnetic interference and improve signal integrity in environments with inverters, motors, switchgear, and dense electrical equipment.

For cross-border sourcing, WDZ-KYJRP is positioned as a premium solution for contractors and system integrators, meeting their needs for LSZH compliance and shielding performance for more reliable control and measurement performance.

Voltage: Typical rated voltages depend on the application category and standards, typically used for low-voltage control ranges such as 300/500 V or 450/750 V.

For instrumentation systems, please confirm the required rated voltage, test requirements, and applicable standards in your Bill of Materials (BOQ).

Common Specifications Overview
Core Configurations Commonly Used in Projects
  • 2-core: Basic signal loop and device connection
  • 3-core, 4-core: Control cabling and multi-point devices
  • 5-core, 7-core, 8-core: Multi-signal control connection
  • 10-core, 12-core, 16-core, 20-core, 24-core: Panel cabling and multi-channel cabling

Depending on the project design, a wire pair structure may be used (please confirm specific requirements)

Common Cross-sectional Areas
  • 0.5 mm², 0.75 mm², 1.0 mm², 1.5 mm², 2.5 mm²
High-Frequency Combinations for Control and Instrumentation
  • 2-core x 0.75 mm², 2-core x 1.0 mm², 2-core x 1.5 mm²
  • 4-core x 0.75 mm², 4-core x 1.0 mm², 4-core x 1.5 mm²
  • 8-core x 0.5 mm², 10-core x 0.5 mm², 12-core x 0.5 mm² 0.5
  • 12C x 0.75, 16C x 0.75
  • 20C x 0.5, 24C x 0.5

Supply depends on shielding type, low-smoke halogen-free compound system, and standards. Please confirm the specific structure to ensure compliance with tender requirements.

Reasons why buyers choose WDZ-KYJRP
Low-smoke halogen-free safety protection for enclosed and public environments

Low-smoke halogen-free compounds are commonly used to reduce smoke concentration and corrosive gases during fires, thus contributing to safer evacuation and reduced equipment damage.

Shielding improves signal stability

Shielding helps reduce electromagnetic interference, thereby improving the reliability of control and measurement circuits near motors, inverters, switching equipment, and power lines.

Neater cabling for complex systems

Multi-core design reduces cable clutter in cable trays and cabinets, improving installation efficiency and maintenance ease.

Reliable Performance for Automation and Instrumentation Applications

Suitable for PLC I/O wiring, sensor loops, and control signals requiring stable transmission and low noise.

Easy for System Integrators to Purchase

Common sizes, standardized configurations, and export packaging support repeat orders from contractors and automation solution providers.

Typical Applications
  • PLC Control and I/O Wiring
  • Instrumentation Signal and Sensor Connections
  • Automation Panels, MCCs, and Control Cabinets
  • Building Management Systems and Industrial Control Loops
  • Signal Wiring in Factories Equipped with Inverters and Motor Drivers
  • Trawl and Conduit Wiring Compliant with Low Smoke Halogen-Free (LSZH) Standards
Process and Manufacturing Notes
Conductor Stranding and Core Insulation

Copper conductors are drawn and stranded for increased flexibility. Each core is insulated with a halogen-free compound.

Core Identification and Wiring

Insulated cores are color-coded or numbered and then stranded in a controlled geometry according to the required number of cores to ensure cable structure stability.

Shielding Applications

Shielding layers (typically copper braids or copper strips, depending on specifications) are applied to reduce electromagnetic interference (EMI) and improve signal integrity.

Low Smoke Halogen-Free (LSZH) Sheath Extrusion

Extruding low smoke halogen-free outer sheaths provides mechanical protection and fire resistance for enclosed circuitry.

Routine Testing and Quality Control

Typical checks include conductor resistance, insulation thickness, spark testing, voltage testing, shielding continuity checks, and dimensional verification.

Structure (Typical Market Specifications)
  • Conductor: Copper stranded wire
  • Core insulation: Halogen-free compound (LSZH/HFFR type, specific specifications vary)
  • Shielding: Copper braid or copper tape (specific specifications vary)
  • Outer sheath: LSZH compound system
  • Cable type: Shielded control/instrumentation cable for fixed installations
Specification Table
Item Value
Cable type WDZ-KYJRP
Application type LSZH shielded control and instrumentation cable
Rated voltage 300/500 V or 450/750 V V (Specific specifications depend on the application)
Conductor Material Copper Stranded Wire
Core Insulation Halogen-Free Insulated Core Wire (Specific specifications depend on the application)
Shielding Type Copper Braided Layer or Copper Strip (Specific specifications depend on the application)
Outer Sheath LSZH (Low Smoke Halogen-Free)
Number of Cores 2 cores to 24°C (Common specifications; other specifications can be customized)
Specifications: Common Cross-Section Sizes 0.5 mm² to 2.5 mm²
Specifications: Typical Maximum Operating Temperature Maximum 70°C or 90°C (Specific temperature depends on the design; please confirm with specifications)
Installation Fixed installation in cable trays, conduits, cabinets, or protected wiring
Packaging Coil or reel packaging; export packaging available
Selection Guide
  1. If your project requires compliance with Low Smoke Halogen-Free (LSZH) standards and shielding to improve signal quality in noisy environments, select WDZ-KYJRP.
  2. Select the core quantity based on the number of channels, and the cross-sectional area based on load current, line length, and voltage drop limitations of the control circuit.
  3. Confirm shielding requirements (braided or tape shielding), grounding method, and applicable standards.
  4. If installing outdoors, underground, or in areas with high mechanical risks, specify wiring conditions for appropriate protection design.
Quick Inquiry Template
Product: WDZ-KYJRP
Rated Voltage: 300/500 V or 450/750 V
Number of Cores: __
Cross-sectional Area: __ mm²
Shielding Type: Braided/Tape
Quantity: __ meters
Installation Method: Tray/Conduit/Rack
Required Standard: __
Destination: Country and Port
Trade Terms: FOB / CIF / Other
Special Requirements: Low Smoke Halogen-Free (LSZH) Performance Grade, Numbering/Printing, Packaging Marking, Inspection Documents
Frequently Asked Questions
Applications of WDZ-KYJRP

It is used in low smoke halogen-free (LSZH) shielded control and instrumentation circuits requiring fire safety and reduced signal interference, such as PLC wiring, sensors, and automation loops.

What is the function of the shielding layer?

The shielding layer helps reduce electromagnetic interference and supports more stable signal transmission near motors, inverters, and switching equipment.

Is WDZ-KYJRP a power cable?

It is primarily used in control, signal, and instrumentation circuits. For power distribution applications, please select dedicated power cables with a rated voltage that matches the load and installation path.

What voltage rating should I choose?

Select the voltage rating based on your control system specifications and local standards. Many projects use 300/500V or 450/750V control cables.

How do I choose the number of cores and size?

The number of cores depends on the number of channels. The cross-sectional area depends on the current, line length, and allowable voltage drop. Please provide your bill of materials for matching.

Can you provide numbered cores and custom markings?

Yes. We can provide numbering, printing, packaging markings, and export documentation according to project and distributor requirements.

Service of JinHong Company
Over Productions Service:

JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

Quality Certification Services:

JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

Profession Customer Service:

JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

Delivery And Shipping Services:

While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.