YJLHV22 Aluminum Alloy Steel Tape Armoured PVC Sheathed Power Cable | STA Underground Armoured Distribution Cable
Product Overview YJLHV22 is a medium-to-low voltage armored power cable designed for demanding underground and outdoor applications, serving as an upgraded successor to the YJLV22 aluminum-conductor cable. It features AA8030 rare-earth creep-resistant aluminum alloy conductors, extruded cross-linked polyethylene (XLPE) insulation, an inner bedding layer, double-layer overlapping galvanized steel tape armor, and a weather-resistant PVC outer sheath. This design effectively
Anti-Creep Aluminum Alloy XLPE Insulated Power Cable for Overhead Trunk, Residential Grid Retrofit & Large Commercial Distribution Wiring
YJHLV Power Transmission Cable: Advanced Aluminum Alloy Conductor Solution A clear breakdown of the model designation helps electrical designers, cost estimators, grid procurement specialists, and construction project managers quickly identify the structural definition and core specifications: Model Designation Breakdown YJ: Cross-linked polyethylene (XLPE) insulation, offering excellent heat resistance and insulation stability, suitable for long-term power transmission. HL:
YH High Temperature Resistant Silicone Rubber Flexible Cable for Heating Equipment, Furnace Wiring & High-Temp Industrial Internal Connection
For electrical design engineers, equipment R&D personnel, procurement managers, and plant project managers, we provide a detailed breakdown of model designations to help quickly clarify product positioning and structural characteristics: Y: Designation for rubber insulation within wire and cable naming standards. H: High-temperature resistance rating—utilizing a custom silicone rubber formulation, it is capable of withstanding long-term, continuous high-temperature operating
YC Heavy-Duty Rubber Flexible Trailing Cable for Construction Trailers, Mobile Machinery & Harsh Site Temporary Power Connections
YC Heavy-Duty Flexible Trailing Rubber Cables A clear breakdown of model specifications helps electrical designers, cost estimators, procurement managers, and equipment OEM engineering teams quickly identify product positioning and structural grade differences: Y: Ethylene-propylene rubber (EPR) primary insulation material. C: Heavy-duty reinforced grade—offering significantly superior tensile strength, tear resistance, and abrasion resistance compared to light-duty YZ-grade
YC Rubber Sheath Flexible Portable Power Cable for Construction Equipment, Site Temporary Power & Outdoor Mobile Electrical Connection
YC Heavy-Duty Flexible Rubber Cables: Product Overview A comprehensive model breakdown for electrical designers, cost engineers, procurement managers, and equipment manufacturers, aimed at clarifying product positioning and structural characteristics: Y: General-purpose rubber insulation material. C: Heavy-duty grade—Compared to the light-duty YZ-type rubber cable, this model offers superior mechanical strength, as well as enhanced tensile, tear, and abrasion resistance. YC
26/35kV WDZ-YJY23 Double Steel Tape Armored LSZH Medium-High Voltage Power Cable for Urban Grid, Tunnel Direct Burial & New Energy Substation Transmission
Detailed model specifications designed for medium-to-high voltage design engineers, cost estimators, grid procurement specialists, and EPC project managers, enabling quick identification of structural classifications and electrical applications: WDZ: Low-smoke, zero-halogen (LSZH), flame-retardant type; supports customization of flame-retardant grades (WDZA/WDZB/WDZC) to meet specific fire safety design requirements. YJ: Thickened XLPE (cross-linked polyethylene) main
8.7/15kV WDZ-YJY23 Double Steel Tape Armored LSZH Medium Voltage Power Cable for Substation, Tunnel & Direct Burial Power Transmission
A detailed model breakdown for medium-voltage design engineers, tender estimators, and procurement specialists to facilitate the quick identification of structural and electrical characteristics: Model Breakdown WDZ: Low-smoke, zero-halogen (LSZH), flame-retardant type; flame-retardant grades (WDZA, WDZB, or WDZC) can be customized based on fire safety design requirements. YJ: Cross-linked polyethylene (XLPE) primary insulation, offering excellent resistance to medium-voltage
0.6/1kV WDZ-YJY23 Steel Tape Armored LSZH Flame Retardant Power Cable for Direct Burial, Tunnel & Underground Infrastructure Wiring
Detailed specifications for this model, enabling electrical designers, cost engineers, and procurement teams to quickly identify its structural characteristics: Product Overview: WDZ-YJY23 0.6/1kV Cable Key Features WDZ: Features low-smoke, zero-halogen, and flame-retardant properties; flame-retardant grades (WDZA/WDZB/WDZC) can be customized as required. YJ: Utilizes cross-linked polyethylene (XLPE) as the primary insulation layer. Y: Employs low-smoke, zero-halogen
WDZ-YJY Low Smoke Zero Halogen Flame Retardant XLPE Insulated Power Cable for Indoor Wiring, Public Buildings & Fire Safety Engineering
WDZ-YJY Cable Product Overview An Analysis of the WDZ-YJY Model Designation: WDZ: Low-smoke, halogen-free, and flame-retardant properties YJ: Cross-linked polyethylene (XLPE) insulation Y: Low-smoke, halogen-free polyolefin outer sheath WDZ-YJY is a widely used unarmored, flame-retardant power cable designed for fixed indoor power transmission and distribution lines. It features solid or stranded oxygen-free copper conductors, XLPE insulation, and a halogen-free, flame
WDZ-YJLHY23 LSZH Aluminum Alloy Steel Tape Armored Power Cable for Underground Direct Burial & Public Infrastructure
WDZ-YJLHY23 Model Code Breakdown WDZ: Low-smoke, zero-halogen, and flame-retardant properties YJ: Cross-linked polyethylene (XLPE) insulation LH: AA8030 series aluminum alloy conductor (creep-resistant alloy) Y: Low-smoke zero-halogen (LSZH) polyolefin bedding layer 23: Double steel tape armor + polyethylene outer sheath, providing mechanical protection for underground installation WDZ-YJLHY23 is a cost-optimized, heavy-duty power cable designed for fixed power transmission
WDZN-YJY Fire-Resistant Power Cable 0.6/1kV LSZH for Heavy Infrastructure & Critical Circuit Integrity
WDZN-YJY is a fire-resistant, low-smoke, zero-halogen (LSZH) power cable widely used in fixed installations for power transmission and distribution circuits. Featuring solid or tinned copper conductors, cross-linked polyethylene (XLPE) insulation, and an LSZH outer sheath, this cable meets the stringent fire safety requirements of densely populated public buildings and critical infrastructure. In the event of a fire, the WDZN-YJY cable emits minimal toxic halogen gases and
WDZ-KYJYRP Low Smoke Zero Halogen Pair Twisted Individual Shielded Control Cable for Precision Instrument, DCS & Fire Alarm Differential Signal Transmission
Professional Model Designation Breakdown for Electrical and Instrumentation Engineers WDZ: Low-Smoke Zero-Halogen (LSZH) type; insulation, fillers, and outer sheath utilize halogen-free polyolefin composite materials, ensuring no toxic or corrosive halogen gases are released during open-flame combustion. K: Control cable; designed specifically for the transmission of low-voltage analog signals, digital differential signals, instrumentation signals, and fire alarm linkage
WDZ-KYJRP Low Smoke Zero Halogen Shielded Control Cable for Automation, Instrument & Fire Linkage Signal Transmission Systems
Interpretation of Technical Specifications for Electrical and Automation Engineers WDZ: Low Smoke Zero Halogen (LSZH); features halogen-free insulation and sheathing; emits minimal, non-toxic smoke during combustion and produces no corrosive, halogen-containing gases. K: Control cable; specifically designed for low-current signal transmission, PLC control, instrumentation interlocking, and fire safety linkage circuits. YJ: XLPE (cross-linked polyethylene) core insulation;
WDZB-YJY Class B Low Smoke Zero Halogen Flame Retardant XLPE Insulated LSZH Sheathed Power Cable for General Commercial, Residential Public Zones & Standard Public Facilities
Explanation of Engineering Terminology WDZ: Low Smoke Zero Halogen (LSZH). Both insulation and sheath materials utilize halogen-free polyolefin composites; they do not emit toxic or corrosive chlorine-containing gases when exposed to fire. B: Class B Flame Retardancy. A standard flame-retardancy rating for general civil buildings, meeting the requirements of the IEC 60332-3B vertical bunched cable combustion test. YJ: Cross-linked Polyethylene (XLPE) insulated core. Produced
WDZBN-YJY73 Class B Enhanced Low Smoke Zero Halogen Steel Tape Armored XLPE Power Cable for Direct Buried, Pipe Gallery & Anti-Mechanical Damage Public Engineering
1. Comprehensive Model Code Breakdown and Multi-layer Armored Cable Structure Analysis Professional code interpretation tailored for electrical engineering teams WDZ: Low Smoke Zero Halogen (LSZH); utilizes halogen-free insulation and sheath materials that do not emit toxic or corrosive gases when exposed to open flames. B: Class B flame-retardant rating; meets moderate fire safety standards for public and civil buildings. N: Enhanced bundled flame-retardant formulation;
WDZBN-YJY Class B Low Smoke Zero Halogen Fire Retardant XLPE Insulated LSZH Sheathed Power Cable for Mid-Rise Commercial, School & General Public Construction
1. Comprehensive Analysis of Cable Model Nomenclature and Layered Internal Structure Technical model interpretation for engineering professionals: WDZ: Low-Smoke Zero-Halogen (LSZH); utilizes halogen-free insulation and sheathing materials that do not release toxic or corrosive halogen gases during combustion. B: Class B flame-retardant rating; suitable for most mid-to-high-rise public buildings with moderate fire safety design requirements. N: Enhanced flame-retardant type;
WDZA-YJY Class A Low Smoke Zero Halogen XLPE Insulated LSZH Sheathed Power Cable for High-Rise, Metro & Public Fire-Critical Engineering
1. Product Designation and Multi-layer Internal Structure Analysis Technical Code Definitions: WDZ: Low Smoke Zero Halogen (LSZH); utilizes halogen-free insulation and sheathing materials that produce minimal smoke and release no toxic halogen gases when exposed to fire. A: Class A smoke suppression rating; meets the highest standards for smoke density and toxicity indices as specified in fire safety codes for civil buildings. YJ: Cross-linked polyethylene (XLPE) insulated
VV Copper Core PVC Insulated PVC Sheathed Low Voltage Distribution Cable for Indoor Fixed Wiring & Civil General Engineering
1. Core Product Definition and Structural Comparison Matrix VV-type cables are low-voltage power cables featuring copper conductors, PVC insulation, and PVC sheathing. Designed specifically for fixed indoor power transmission, they are suitable for applications that do not require special fire resistance, high-temperature tolerance, or resistance to prolonged outdoor exposure. Their dual-layer PVC composite structure offers balanced basic insulation and physical protection,
VV Copper Core PVC Insulated PVC Sheathed Low Voltage Power Cable for Indoor General Fixed Distribution Engineering
1. Product Definition and Layered Internal Structure Analysis VV cable is defined as a low-voltage power cable featuring copper conductors, PVC insulation, and a PVC outer sheath; it is widely used in indoor fixed-installation power transmission and distribution systems where there are no stringent requirements for fire resistance or high-temperature tolerance. Utilizing a dual-layer PVC composite structure paired with high-conductivity copper cores, this cable is positioned
VLV Aluminum Core PVC Insulated PVC Sheathed Low Voltage Power Cable for Outdoor Civil & Municipal Fixed Distribution Projects
1. Product Overview and Structural Composition VLV cable is a low-voltage power cable featuring aluminum conductors, PVC insulation, and a PVC outer sheath; it is designed for fixed-installation power transmission and distribution systems that do not require special fire-resistance or emergency power supply capabilities. The structural layers, from inner to outer, are as follows: Compacted stranded aluminum conductor: Made from industrial-grade pure aluminum wire using a
NH-YJV Fire Resistant Crosslinked Polyethylene Insulated PVC Sheathed Power Cable for Construction & Municipal Engineering
1. Basic Product Definition and Core Technical Composition The NH-YJV cable is a Class A fire-resistant power cable featuring cross-linked polyethylene (XLPE) insulation and a polyvinyl chloride (PVC) sheath; it is designed for fixed-installation power transmission and distribution systems subject to mandatory fire-resistance requirements. Its comprehensive structure comprises a copper conductor core, an XLPE insulation layer, a fire-resistant barrier wrapping layer, filler
Fire Resistant PVC Insulated PVC Sheathed Copper Power Cable For Fire Lifeline, Emergency Lighting & Critical Safety Circuit Distribution
1. Compliance with National Standards and a Complete Fire Resistance Certification System NH-VV series fire-resistant PVC insulated and PVC sheathed power cables strictly comply with the requirements of the national standard GB/T 5023-2023 "PVC Insulated Power Cables". The fire-resistant core material performance fully complies with GB/T 19665 "Test Standard for Fire-Resistant Cables" and meets the international standard IEC 60227 "Specification for PVC Low-Voltage Cable
Low Voltage Steel Tape Armoured PVC Sheathed Cable for Industrial & Civil Construction Power Distribution
Product Core Definition and Production Standard Compliance The YJV22-0.6/1kV 3×95+1×50 XLPE insulated double-steel-tape armored copper cable is a fixed-lay low-voltage trunk cable specifically designed for global building, industrial, and municipal power distribution projects. All manufacturing processes strictly adhere to the domestic standard GB/T12706-2020 and the international standard IEC 60502, and it is suitable for 50Hz AC transmission systems. Its five-layer
YJLV22 Double Steel Tape Armored XLPE Insulated Aluminum Power Cable for Rural Grid Upgrade, Port Yard & Open Pit Mining Underground Cabling Bulk Sourcing
YJLV22 is an economical armored aluminum power cable designed according to GB/T12706 and the harmonized IEC 60502 international standards. It consists of high-purity aluminum stranded conductors, cross-linked polyethylene insulation, a PVC inner lining, overlapping double-layer steel tape armor, and a weather-resistant PVC outer sheath. Unlike copper-based YJV22 and AA8000 alloy YJLHV22 armored cables, YJLV22 uses conventional high-purity electrical aluminum, significantly