×
Quality Durable Medium Voltage Cables YJV22 STA Armored XLPE Copper Cable 8.5/15kV Designed for Underground Power Distribution Systems factory
Quality Durable Medium Voltage Cables YJV22 STA Armored XLPE Copper Cable 8.5/15kV Designed for Underground Power Distribution Systems factory

Durable Medium Voltage Cables YJV22 STA Armored XLPE Copper Cable 8.5/15kV Designed for Underground Power Distribution Systems

Product Specification
Place of Origin: Anhui China
Brand Name: JinHong
Certification: CE
Model Number: YJV22
Minimum Order Quantity: 100m
Price: 9.15-15USD/m
Delivery Time: 10-20Days
Payment Terms: T/T

Product Summary

Rated Voltage Typical Rated Voltage:8.7/15 kV Applications: Medium-voltage distribution feeders and sub-feeders (fixed installation) Please confirm the reference standards and test ranges listed in your Bill of Materials (BOQ). General Specifications Overview Common Core Wire Configurations ...

Product Details

Conductormaterial: Copper Or Aluminum
Application: Power Distribution In Industrial Environments
Productname: Industrial Power Cables
Temperaturerange: -40°C To +90°C
Standardscompliance: IEC, BS, UL, Or IEEE
Waterresistance: Water Resistant Or Waterproof
Colorcode: Black, Red, Blue, Yellow, Green, Etc.
Voltagerating: Up To 35kV
Armouring: Steel Wire Armoured (SWA) Or Non-Armoured
Sheathmaterial: PVC, PE, Or LSZH
Insulationmaterial: PVC, XLPE, Or Rubber
Installationmethod: Underground, Direct Burial, Or Overhead
Cablediameter: Varies Based On Conductor Size
Cabletype: Single Core Or Multi Core
Flameretardant: Yes

Product Description


Rated Voltage

Typical Rated Voltage:8.7/15 kV

Applications: Medium-voltage distribution feeders and sub-feeders (fixed installation)

Please confirm the reference standards and test ranges listed in your Bill of Materials (BOQ).

General Specifications Overview
Common Core Wire Configurations (Depending on Project)
  • 1C for high current, phase-separated wiring
  • 2C for single-phase feeders and dedicated circuits
  • 3C for three-phase circuits without a neutral conductor (Depending on Design)
  • 4C for three-phase circuits with a neutral conductor (common)
  • 5C for three-phase circuits with a neutral conductor and protective wiring (Depending on Design)
  • 3+1 and 3+2 are used in many bills of quantities for feeder configurations
Common Cross-Section Dimensions (mm²)
  • 1.5
  • 2.5
  • 4
  • 6
  • 10
  • 16
  • 25
  • 35
  • 50
  • 70
  • 95
  • 120
  • 150
  • 185
  • 240
  • 300
  • 400
Common High-Demand Combinations Used by Contractors
  • 4C x 10 4C x 16 4C x 25 4C x 35 4C x 50
  • 5C x 10 5C x 16 5C x 25 5C x 35
  • 3C x 10 3C x 16 3C x 25
  • 1C x 95 1C x 120 1C x 150 1C x 185 1C x 240
Applications of YJV22
  • Underground conduits and cable trenches
  • Protective trench wiring in industrial and commercial locations
  • Incoming lines to main low-voltage switchboards
  • Utility corridors and cable tunnels with external pressure risks
  • Indoor/outdoor feeder transitions requiring higher mechanical strength
  • Fixed wiring with high cable handling and pull-out stress
Reasons buyers choose YJV22
Provides armored protection for conduits and trenches

Uses steel tape armor to improve compressive strength and resistance to external pressure, ensuring the reliability of protected underground wiring.

XLPE insulation ensures stable performance

XLPE insulation provides reliable dielectric strength and thermal properties, suitable for continuous load feeders.

High-efficiency copper conductors for power transmission

Copper conductors offer excellent conductivity and stable voltage drop control, making them particularly suitable for long-distance feeders.

Easy-to-install PVC sheath

The PVC sheath provides abrasion resistance and durable surface protection, facilitating pulling and field handling.

Directly applicable to large bills of quantities procurement

Standardized construction and widely used sizes facilitate repeated supply, phased delivery, and streamline bill of quantities matching.

Structural Overview
  • Conductor: Copper stranded wire
  • Insulation: Cross-linked polyethylene (XLPE)
  • Inner Layer: Filler/adhesive added as needed to ensure geometric stability
  • Protective Layer: Protective layer beneath the armor layer
  • Armor Layer: Steel tape (STA)
  • Outer Sheath: Polyvinyl chloride (PVC)
  • Applications: Fixed installation, especially suitable for protected underground lines
Manufacturing and Process Description
  1. Conductor Preparation

    Controlling the stranding pattern of the copper wires to meet resistance targets and facilitate installation bending.

  2. Cross-linked polyethylene (XLPE) Insulation and Cross-linking

    Using extrusion and cross-linking processes to form a stable dielectric layer suitable for low-voltage feeder applications.

  3. Cable and Geometry Control

    Controlling the core wire layup to maintain the cable's roundness and dimensional stability, resulting in smoother pulling and a consistent sheath finish.

  4. Protective Layer Formation

    Laying the protective layer to protect the cable cores and provide a stable base for the armor layer.

  5. Steel Tape Armor

    Using a controlled overlap method to wind steel tape, primarily enhancing the cable's resistance to compression and external pressure. PVC Sheath Extrusion and Marking

  6. PVC Sheath Extrusion and Marking

    PVC sheaths protect the armor layer and internal structure and are marked for easy traceability and project control.

  7. Routine Inspections

    Typical inspections include conductor resistance, insulation thickness verification, spark testing, voltage testing, dimensional inspection, and sheath integrity checks.

Specifications
Model YJV22
Cable Category Copper Core XLPE Insulated PVC Sheathed Steel Tape Armored Low-Voltage Power Cable
Rated Voltage 8.5/15 kV
Conductor Copper, Stranded
Insulation XLPE
Armor Steel Tape (STA)
Outer Sheath PVC
Core Options 1 core, 2 cores, 3 cores, 4 cores, 5 cores, 3+1 cores, 3+2 cores
Common Size Range 1.5 to 400 mm²
Typical Operating Temperature Up to 90℃ (XLPE design, specific standard depends on the situation)
Installation Methods Conduit, Cable Trench, Protective Trench, Cable Corridor, Fixed Underground Lines
Packaging Most sizes are packaged in reels, smaller sizes in coils (depending on the project)
Optional Configurations Custom markings, packaging markings, reel length, accompanying documentation
Selection Guide
  • When the line requires armor protection and fixed installation, please select YJV22 cable. For conduits, trenches, and protected underground passages.
  • Select the number of conductors based on the neutral and protective earth (PE) wiring design.
  • Select the cross-sectional area based on current, distance, grouping, ambient temperature, and permissible voltage drop.
  • If the project requires flame retardancy, low smoke halogen-free (LSZH), or fire resistance, specify the required category to match the correct model.

FAQ
What are the main applications of YJV22?
It is used in fixed-installation low-voltage power distribution systems, especially suitable for applications where steel tape armor is used for path protection, such as cable trenches, protective trenches, and building entrances.
What does the number 22 usually represent?
In many naming systems, the number 22 is often associated with steel tape armor construction. Always follow the definitions and test ranges of the relevant standards.
What is the difference between YJV22 and YJV?
YJV22 includes a single layer of steel tape armor, providing mechanical protection. YJV typically does not have an armor layer.
Can YJV22 be used for direct burial?
It is typically used in conduits and protective trenches. The suitability for direct burial depends on soil conditions, mechanical risks, and local code requirements. Please provide detailed route information for proper selection.
What are the most commonly used specifications in projects?
In power distribution lines, commonly used specifications are 4-core and 5-core cables with a span of 10 to 50 mm². For high-current feeders, common specifications are 95 to 240 mm² single-core cables, depending on the load and distance.
What information is needed for a quick quote?
Core configuration, specification list, total meters, required standards, installation route, destination, reel length requirements, and required documentation.
Service of JinHong Company
Over Productions Service:

JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

Quality Certification Services:

JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

Profession Customer Service:

JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

Delivery And Shipping Services:

While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.

You May Also Like