Underground Feeder Networks YJV22 Cable STA 0.6/1kV XLPE Copper Armoured Cable

Underground Feeder Networks YJV22 Cable STA 0.6/1kV XLPE Copper Armoured Cable

Brand Name: JinHong
Model Number: YJV22
MOQ: 100m
Price: 7.25-35 USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Conductor Type:
Class 2
Insulationmaterial:
PVC, XLPE, Or Rubber
Waterresistance:
Water Resistant Or Waterproof
Cable Type:
FRC Armoured Cable
Weight:
Varies Depending On Size And Construction
Transport Package:
500m/Reel
Rated Voltage:
6/10KV
Voltage Rating:
600/1000V
Armour Type:
Steel Wire Armoured
Origin:
Shanghai China
Cable Voltage:
600V To 35KV
Voltagerating:
300/500V To 33kV
Armour:
Steel Tape Armoured
Sheath Material:
PVC/PE/LSOH
Current:
DC & AC
Highlight:

Underground Feeder Networks YJV22 Cable

,

YJV22 Cable STA 0.6/1kV

,

0.6/1kV XLPE Copper Armoured Cable

Product Description

YJV22 Copper XLPE STA Armored Cable 0.6/1kV for Underground Feeder Networks

When your low-voltage lines are laid underground, protection becomes an integral part of their performance. YJV22 cable combines copper conductors, cross-linked polyethylene (XLPE) insulation, and steel tape armor to ensure your feeders remain reliable in conduits, cable trays, and protected trenches. YJV22 cable is ideal for projects requiring armored low-voltage cable but not necessarily low-smoke halogen-free (LSZH) or fire-resistant properties.

Product Overview

YJV22 is a low-voltage armored power cable typically featuring stranded copper conductors and cross-linked polyethylene (XLPE) insulation, reinforced with steel tape armor (STA), and finally protected by a polyvinyl chloride (PVC) outer sheath. This cable is designed with a focus on ensuring reliable fixed installations in underground and mechanically sensitive lines, helping to reduce the risk of damage from compression, backfill stress, and difficult-to-stretch sections. It is commonly used in building access lines, industrial power distribution, campus utilities, and infrastructure projects where line durability is a primary consideration in procurement.

Rated Voltage

Typical Rated Voltage: 0.6/1 kV

Applications: Fixed low-voltage feeders and sub-feeders

Common Specifications Overview
Common Core Configurations (Project-Specific)
  • 1C High-Current Feeders (Phase Separate Wiring)
  • 2C Single-Phase Circuits and Dedicated Loads
  • 3C Three-Phase Circuits Without Neutral (Design-Specific)
  • 4C Three-Phase with Neutral Distribution
  • 5C Three-Phase with Neutral and PE (Design-Specific)
  • 3+1 and 3+2 Feeder Configurations Used in Many Bills of Quantities (BOQs)
Common Ordering Cross-Section Dimensions (mm²)

1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400

Common Contractor Combinations
  • 4C x 10 4C x 16 4C x 25 4C x 35 4C x 50
  • 5C x 10 5C x 16 5C x 25 5C x 35
  • 3C x 10 3C x 16 3C x 25
  • 1C x 95 1C x 120 1C x 150 1C x 185 1C x 240
Typical Applications
  • Underground conduit and cable trench power distribution
  • Protective trench installation in industrial and commercial sites
  • Incoming lines to low-voltage switchboards and distribution boxes
  • Utility corridors, cable channels, and line transitions
  • Indoor and outdoor feeder installations subjected to high mechanical stress
  • Fixed installations requiring armored construction
Reasons Buyers Choose YJV22
Armored drive reliability of underground lines

Steel strip armor enhances compressive strength and resistance to external pressure, ensuring long-term performance of conduits and cable trenches.

Copper conductors offer superior performance and effectively control voltage drop.

Copper conductors provide efficient conductivity and stable feeder performance, making them particularly suitable for long-distance low-voltage power distribution.

XLPE insulation ensures reliable low-voltage operation.

XLPE insulation provides stable dielectric properties and continuous load capacity in typical low-voltage feeder applications.

PVC sheath for durability.

The PVC outer sheath is abrasion-resistant, facilitating handling during traction, laying, and termination preparation.

Easy procurement for large bills of quantities.

Common sizes and familiar construction help reduce substitution risks and expedite project supply planning.

Structural Overview
  • Conductor: Copper stranded wire
  • Insulation: Cross-linked polyethylene (XLPE)
  • Side Pad: Protective pad layer beneath the armor layer
  • Armor Layer: Steel tape (STA)
  • Outer Sheath: Polyvinyl chloride (PVC)
  • Installation Type: Fixed, suitable for specially protected underground power distribution lines
Process and Technical Specifications
  • Copper Conductor Stranding

    Controlled stranding structure helps improve resistance stability and facilitates installation.

  • XLPE Insulation Extrusion and Cross-linking

    Insulation layer molding ensures durable dielectric properties for low-voltage power distribution lines.

  • Core Identification and Assembly

    Core wires are identified and stranded using controlled geometry to maintain roundness and facilitate pull-out.

  • Side Pad Preparation

    The side pad protects the core wire assembly and helps with the stable installation of the armor layer.

  • Steel Tape Armoring

    Steel tape is wound in a controlled overlap manner to enhance compressive strength and resistance to external pressure.

  • PVC Sheath Extrusion and Marking

    The sheath protects the armor layer and enables traceability through clear marking. Routine Quality Inspections

  • Typical inspections include conductor resistance, insulation thickness, spark testing, voltage testing, dimensional inspection, and sheath integrity.
Specifications
Item Details
Model YJV22
Type Copper/XLPE/Steel Tape/PVC Armored Low-Voltage Power Cable
Rated Voltage 0.6/1 kV
Conductor Copper Stranded Wire
Insulation Cross-linked Polyethylene (XLPE)
Armor Steel Tape Armored (STA)
Outer Sheath Polyvinyl Chloride (PVC)
Core Options Single Core, 2 Cores, 3 Cores, 4 Cores, 5 Cores, 3+1, 3+2
Common Size Range 1.5 to 400 mm²
Typical Operating Temperature Up to 90°C (XLPE design, depending on standard)
Installation Methods Cable Trench, Conduit, Protective Trench, Corridor, Fixed Underground Cables
Packaging Export Reel (most sizes), Coil (small sizes, depending on project)
Options Marking Language, Packaging Marking, Reel Length Scheme, Documentation List
Ordering Guide
  1. Confirm Your Bill of Materials (BOQ) Standards and acceptance tests specified in the regulations
  2. Provide line type and installation method (cable trench, conduit, protective trench, corridor, incoming feeder)
  3. Provide conductor configuration according to neutral and PE design
  4. Provide cross-sectional dimensions and total length (meters)
  5. Indicate recommended reel length to reduce joints
  6. Indicate special conditions, such as moisture, chemically corrosive areas, impact risks, or direct burial requirements
Quick Inquiry Template
Product: YJV22
Voltage: 0.6/1 kV
Required Standards: __
Conductor Configuration: __
Cross-sectional Dimensions and Quantity: __
Total Length: __ meters
Installation Line: __
Destination Country and Port: __
Trade Terms: __
Recommended Reel Length: __
Required Documents: __
Remarks: Markup Language, Delivery Schedule, Inspection Requirements
Frequently Asked Questions
Question 1: What is the application of YJV22?

YJV22 is a low-voltage distribution cable for fixed installations, suitable for underground or protected lines requiring steel tape armor, such as conduits and trenches.

Q2: What does 22 represent?

A: In many naming systems, 22 indicates a steel-tape armored structure. Ensure its definition and testing scope match the standards required for the project.

Q3: What is the difference between YJV22 and YJV?

A: YJV22 includes an armor layer for mechanical protection. YJV is typically unarmored and used in applications with lower mechanical risk.

Q4: Is YJV22 suitable for direct burial?

A: It is commonly used for conduit assemblies and protected trenches. The suitability for direct burial depends on local regulations, soil conditions, and mechanical risk. Please provide wiring details for accurate matching.

Q5: What are the common specifications for power distribution projects?

A: Common specifications for building power distribution are multi-core 4-core and 5-core cables ranging from 10 to 50 mm². Single-core diameters range from 95 to 240 mm², suitable for high-current wire feeders; specific specifications depend on the load and distance.

Q6. What information helps expedite a quote?

A. Standard specifications, number of cores, size list, total meters, feed path type, destination, spool length preference, and required documentation.

Service of JinHong Company
Over Productions Service:

JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

Quality Certification Services:

JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

Profession Customer Service:

JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

Delivery And Shipping Services:

While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.