LSZH Fire Resistant XLPE Power Cable WDZN-YJY For Emergency Feeders
Product Summary
Product Details
Fire Resistant XLPE Power Cable
,LSZH Fire Resistant XLPE Cable
,XLPE Power Cable WDZN-YJY
Product Description
WDZN-YJY LSZH Fire-Resistant XLPE Power Cable for Emergency Feeders
WDZ-KYJYRP is a low-smoke, halogen-free (LSZH) shielded control cable designed for safety-focused buildings and industrial sites that demand both fire-safety performance and stable signal transmission. It is commonly used for automation control, PLC I/O wiring, instrumentation loops, sensor connections, and low-voltage control circuits routed through trays, conduits, and control cabinets. The shielding layer helps reduce electromagnetic interference, making it well-suited for environments with variable frequency drives, motors, switchgear, and dense power cabling.
Compared with standard PVC control cables, WDZ-KYJYRP is positioned for projects that need reduced smoke and corrosive gas release while keeping signal quality dependable in electrically noisy routes.
Typical rated voltage depends on the application class and local standard. Common control-cable ratings include 300/500 V and 450/750 V.
For control and instrumentation projects, confirm the required voltage rating and test requirements in your BOQ.
Common core configurations used in projects
- 2C: basic instrument loops and device connections
- 3C, 4C: multi-point control wiring
- 5C, 7C, 8C: extended control circuits and device groups
- 10C, 12C, 16C: panel-to-panel multi-channel wiring
- 20C, 24C: higher-channel control cabinets and automation systems
- Pair-based constructions may be used for certain signal designs (spec dependent)
Common cross-sections frequently requested
- 0.5 mm2, 0.75 mm2, 1.0 mm2, 1.5 mm2, 2.5 mm2
High-frequency procurement combinations
- 2C x 0.75, 2C x 1.0, 2C x 1.5
- 4C x 0.75, 4C x 1.0, 4C x 1.5
- 8C x 0.5, 10C x 0.5, 12C x 0.5
- 12C x 0.75, 16C x 0.75
- 20C x 0.5, 24C x 0.5
Availability varies by shielding type, LSZH compound system, and the requested standard. Confirm exact construction for tender compliance.
- LSZH safety for enclosed routes and public buildings
Low-smoke halogen-free compounds are commonly specified to reduce smoke density and corrosive gases during fire scenarios, supporting safer evacuation and reducing damage to sensitive equipment. - Shielding for improved signal integrity
The shield layer helps reduce electromagnetic interference, improving reliability for automation signals, sensor feedback, and control circuits in electrically noisy environments. - XLPE insulated cores for stable electrical performance
XLPE insulation on cores supports dependable dielectric performance and thermal capability for control and multi-core routing. - Efficient installation for complex systems
Multi-core design reduces cable clutter and improves cable management in trays and cabinets, supporting faster commissioning and maintenance. - Procurement-ready for integrators and contractors
Standard core counts, common sizes, and export packing support repeat ordering for automation projects and multi-site deployments.
- PLC control and I/O wiring
- Instrumentation loops and sensor circuits
- Automation panels, MCCs, and control cabinets
- Building management systems and industrial control wiring
- Signal routes near VFDs, motors, and switchgear
- Tray and conduit installations requiring LSZH compliance
- Conductor stranding and core insulation
Copper conductors are drawn and stranded for flexibility. XLPE insulation is applied to each core with controlled thickness for stable performance. - Core identification and cabling
Cores are numbered or color-coded, then laid up to the specified core count with stable geometry to support consistent cable roundness. - Shield application
A shielding layer is applied, commonly copper braid or copper tape depending on specification, to improve EMI resistance and signal stability. - LSZH sheath extrusion
A low-smoke halogen-free sheath is extruded to provide route protection and fire-safety performance in enclosed environments. - Routine tests and inspections
Typical checks include conductor resistance, insulation thickness, spark tests, voltage tests, shielding continuity checks, and dimensional verification. Documentation can be provided as required.
| Item | Value |
|---|---|
| Cable model | WDZ-KYJYRP |
| Application type | LSZH shielded XLPE control cable |
| Rated voltage | 300/500V or 450/750 V (spec dependent) |
| Conductor material | copper, stranded |
| Core insulation | XLPE |
| Shield type | copper braid or copper tape (spec dependent) |
| Outer sheath | LSZH (low smoke halogen free) |
| Core count | 2C to 24C common, other counts by request |
| Common cross-sections | 0.5 mm2 to 2.5 mm2 |
| Typical max operating temperature | up to 70 C or 90 C (design dependent, confirm per specification) |
| Installation | fixed installation in trays, conduits, cabinets, protected routes |
| Packaging | coils or drums, export packing available |
- Choose WDZ-KYJYRP when your project requires LSZH compliance and shielding to improve signal quality in noisy electrical environments.
- Select core count based on channel quantity and future expansion; select cross-section based on circuit current, run length, and allowable voltage drop.
- Confirm shield type and grounding practice to ensure shielding effectiveness.
- If the route is outdoors, underground, or subject to high mechanical risk, specify environment details for the correct sheath and protection design.
It is used for LSZH shielded control and instrumentation circuits requiring stable signal transmission and improved EMI resistance, such as PLC wiring, sensors, and automation loops.
Shielding reduces electromagnetic interference from motors, inverters, and switchgear, helping maintain reliable control signals and reducing noise-related faults.
It is mainly used for control and signal circuits. For main power feeders, choose a dedicated LV power cable matched to the load and installation route.
Select based on your control system specification and local standard. Many projects specify 300/500 V or 450/750 V for control cables.
Core count depends on the number of channels and devices. Cross-section depends on current demand and run length. Share your channel list and distances for matching.
Yes. Numbering, printing, packing marks, and export documentation can be provided for contractor and distributor programs.
- Over Productions Service:
JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them. - Quality Certification Services:
JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs. - Profession Customer Service:
JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions. - Delivery And Shipping Services:
While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.
JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.