products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Low Smoke Zero Halogen Cable
Created with Pixso.

LSZH Fire Resistant XLPE Power Cable WDZN-YJY For Emergency Feeders

LSZH Fire Resistant XLPE Power Cable WDZN-YJY For Emergency Feeders

Brand Name: JinHong
Model Number: WDZN-YJY
MOQ: 100m
Price: 10.15-20 USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Cores No:
2 Cores
Cores:
Muti-cores
Ul Number:
E472913
Number Of Cores:
1,2,3,4,5
Tape:
Mica Tape
Certificates:
CE KEMA VDE,IEC
Warranty:
2 Years
Applications:
Smoke Emission And Toxic Fumes
Conductor:
Add Mica-Tape
Smoke Emission:
Low Smoke Emission
Halogen Content:
Halogen Free
Sheath Material:
LSZH Outer Sheath
Structure:
CU/PO
Model Name:
LSZH Electric Wire
Package:
Drum
Highlight:

Fire Resistant XLPE Power Cable

,

LSZH Fire Resistant XLPE Cable

,

XLPE Power Cable WDZN-YJY

Product Description

WDZN-YJY LSZH Fire-Resistant XLPE Power Cable for Emergency Feeders

WDZ-KYJYRP LSZH Shielded Control Cable

WDZ-KYJYRP is a low-smoke, halogen-free (LSZH) shielded control cable designed for safety-focused buildings and industrial sites that demand both fire-safety performance and stable signal transmission. It is commonly used for automation control, PLC I/O wiring, instrumentation loops, sensor connections, and low-voltage control circuits routed through trays, conduits, and control cabinets. The shielding layer helps reduce electromagnetic interference, making it well-suited for environments with variable frequency drives, motors, switchgear, and dense power cabling.

Compared with standard PVC control cables, WDZ-KYJYRP is positioned for projects that need reduced smoke and corrosive gas release while keeping signal quality dependable in electrically noisy routes.

Key Specifications
Voltage

Typical rated voltage depends on the application class and local standard. Common control-cable ratings include 300/500 V and 450/750 V.
For control and instrumentation projects, confirm the required voltage rating and test requirements in your BOQ.

Common Specifications Summary

Common core configurations used in projects

  • 2C: basic instrument loops and device connections
  • 3C, 4C: multi-point control wiring
  • 5C, 7C, 8C: extended control circuits and device groups
  • 10C, 12C, 16C: panel-to-panel multi-channel wiring
  • 20C, 24C: higher-channel control cabinets and automation systems
  • Pair-based constructions may be used for certain signal designs (spec dependent)

Common cross-sections frequently requested

  • 0.5 mm2, 0.75 mm2, 1.0 mm2, 1.5 mm2, 2.5 mm2

High-frequency procurement combinations

  • 2C x 0.75, 2C x 1.0, 2C x 1.5
  • 4C x 0.75, 4C x 1.0, 4C x 1.5
  • 8C x 0.5, 10C x 0.5, 12C x 0.5
  • 12C x 0.75, 16C x 0.75
  • 20C x 0.5, 24C x 0.5

Availability varies by shielding type, LSZH compound system, and the requested standard. Confirm exact construction for tender compliance.

Why Buyers Choose WDZ-KYJYRP
  • LSZH safety for enclosed routes and public buildings
    Low-smoke halogen-free compounds are commonly specified to reduce smoke density and corrosive gases during fire scenarios, supporting safer evacuation and reducing damage to sensitive equipment.
  • Shielding for improved signal integrity
    The shield layer helps reduce electromagnetic interference, improving reliability for automation signals, sensor feedback, and control circuits in electrically noisy environments.
  • XLPE insulated cores for stable electrical performance
    XLPE insulation on cores supports dependable dielectric performance and thermal capability for control and multi-core routing.
  • Efficient installation for complex systems
    Multi-core design reduces cable clutter and improves cable management in trays and cabinets, supporting faster commissioning and maintenance.
  • Procurement-ready for integrators and contractors
    Standard core counts, common sizes, and export packing support repeat ordering for automation projects and multi-site deployments.
Typical Applications
  • PLC control and I/O wiring
  • Instrumentation loops and sensor circuits
  • Automation panels, MCCs, and control cabinets
  • Building management systems and industrial control wiring
  • Signal routes near VFDs, motors, and switchgear
  • Tray and conduit installations requiring LSZH compliance
Process and Manufacturing Notes
  • Conductor stranding and core insulation
    Copper conductors are drawn and stranded for flexibility. XLPE insulation is applied to each core with controlled thickness for stable performance.
  • Core identification and cabling
    Cores are numbered or color-coded, then laid up to the specified core count with stable geometry to support consistent cable roundness.
  • Shield application
    A shielding layer is applied, commonly copper braid or copper tape depending on specification, to improve EMI resistance and signal stability.
  • LSZH sheath extrusion
    A low-smoke halogen-free sheath is extruded to provide route protection and fire-safety performance in enclosed environments.
  • Routine tests and inspections
    Typical checks include conductor resistance, insulation thickness, spark tests, voltage tests, shielding continuity checks, and dimensional verification. Documentation can be provided as required.
Construction
Conductor: copper, stranded
Core insulation: XLPE
Shield: copper braid or copper tape (spec dependent)
Outer sheath: LSZH compound system
Cable type: shielded LSZH control and instrumentation cable for fixed installation
Specification Table
Item Value
Cable model WDZ-KYJYRP
Application type LSZH shielded XLPE control cable
Rated voltage 300/500V or 450/750 V (spec dependent)
Conductor material copper, stranded
Core insulation XLPE
Shield type copper braid or copper tape (spec dependent)
Outer sheath LSZH (low smoke halogen free)
Core count 2C to 24C common, other counts by request
Common cross-sections 0.5 mm2 to 2.5 mm2
Typical max operating temperature up to 70 C or 90 C (design dependent, confirm per specification)
Installation fixed installation in trays, conduits, cabinets, protected routes
Packaging coils or drums, export packing available
Selection Guide
  • Choose WDZ-KYJYRP when your project requires LSZH compliance and shielding to improve signal quality in noisy electrical environments.
  • Select core count based on channel quantity and future expansion; select cross-section based on circuit current, run length, and allowable voltage drop.
  • Confirm shield type and grounding practice to ensure shielding effectiveness.
  • If the route is outdoors, underground, or subject to high mechanical risk, specify environment details for the correct sheath and protection design.
Fast RFQ Template
Product: WDZ-KYJYRP
Rated voltage: 300/500 V or 450/750 V
Core count: __
Cross-section: __ mm2
Shield type: braid / tape
Quantity: __ meters
Installation route: tray / conduit / cabinet
Required standard: __
Destination: country and port
Trade term: FOB / CIF / other
Special requirements: LSZH performance level, numbering/printing, packing marks, inspection documents
FAQ
What is WDZ-KYJYRP used for

It is used for LSZH shielded control and instrumentation circuits requiring stable signal transmission and improved EMI resistance, such as PLC wiring, sensors, and automation loops.

How does shielding help in real installations

Shielding reduces electromagnetic interference from motors, inverters, and switchgear, helping maintain reliable control signals and reducing noise-related faults.

Is WDZ-KYJYRP suitable for power distribution

It is mainly used for control and signal circuits. For main power feeders, choose a dedicated LV power cable matched to the load and installation route.

What voltage rating should be selected

Select based on your control system specification and local standard. Many projects specify 300/500 V or 450/750 V for control cables.

How do I choose core count and cross-section

Core count depends on the number of channels and devices. Cross-section depends on current demand and run length. Share your channel list and distances for matching.

Can you supply customized numbered cores and marking

Yes. Numbering, printing, packing marks, and export documentation can be provided for contractor and distributor programs.

Service of JinHong Company
  • Over Productions Service:
    JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.
  • Quality Certification Services:
    JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.
  • Profession Customer Service:
    JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.
  • Delivery And Shipping Services:
    While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.
Packaging of JinHong

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.