products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
ABC Overhead Cable
Created with Pixso.

JKLGYJ 10kV Aluminum Core Cross-linked Polyethylene Insulated Reinforced Overhead Cable

JKLGYJ 10kV Aluminum Core Cross-linked Polyethylene Insulated Reinforced Overhead Cable

Brand Name: JinHong
Model Number: JKLGYJ
MOQ: 100m
Price: 10.15-20 USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Highlight:

Overhead Insulated Cable JKLGYJ 10kV

,

JKLGYJ 10kV Aerial Bundled Cable

,

Aluminum Core Aerial Bundled Cable

Product Description
JKLGYJ insulated overhead conductor

JKLGYJ is an insulated overhead conductor suitable for overhead distribution lines requiring weather resistance, safer spacing, and high tensile strength. It is ideal for power system upgrades, rural electrification, and long-span overhead lines.

Build a stronger, less disruptive overhead power grid. JKLGYJ insulated overhead conductors are designed for outdoor distribution lines, withstanding wind, vegetation, and long spans, ensuring reliable mechanical strength and stable insulation performance.

Features of JKLGYJ

JKLGYJ is typically supplied as a 10kV insulated overhead conductor (insulated conductor) with an aluminum-based conductor (usually reinforced with steel wire for increased tensile strength) and a cross-linked polyethylene (XLPE) insulation layer. This "insulated" design is designed to improve line safety and reduce the risk of failure due to accidental contact, tree branches, and exposure to severe weather compared to bare conductors.

What JKLGYJ is Not

JKLGYJ is not a fully sheathed underground cable. It is primarily used for overhead installation on poles/towers and should be selected along with the correct accessories, fittings, and overhead system installation methods.

Typical Voltage Levels (Low/Medium Voltage Distribution)

Typically used in overhead distribution networks around 10kV (specific voltage level depends on the project). If your system is 6kV, 10kV, or other medium voltage distribution levels, please specify the rated voltage, insulation thickness, and standard requirements in your Request for Quotation (RFQ).

Applications of JKLGYJ
Utility and Distribution Projects
  • Overhead Distribution Feeders and Branch Lines
  • Rural Electrification and Grid Expansion
  • Lines traversing densely vegetated areas; clad conductors reduce fault risk.
  • Urban or Suburban Upgrades, prioritizing safety margins and minimizing outages.
  • Mountainous areas, river crossings, and long spans requiring higher tensile strength.
Industry and Infrastructure
  • Surrounding Power Distribution at Factories
  • Distribution Lines in Mining Areas and Rugged Terrain
  • Temporary or Phased Construction Power Supply on Overhead Lines (where permitted by local regulations)
Why Buyers Choose JKLGYJ
  • Safer Overhead Line Cabling Strategies
  • Clad insulation helps reduce accidental contact faults and improves the sense of security for lines in public corridors and narrow right-of-way areas.
  • Superior Span Mechanical Performance
  • Reinforced conductor options are typically used to handle higher tensile strength, longer spans, and complex terrain.
  • Weather Resistance and Outdoor Durability
  • XLPE insulation maintains stable outdoor performance under temperature fluctuations, sunlight exposure, and long-term overhead operation.
  • Reduces the risk of line disruptions in actual corridors
  • Commonly used in vegetated areas and areas where branches meet, as exposed conductors are more prone to tripping in these areas.
  • Faster utility-grade installation
  • Equipped with matching connectors, terminals, lifting clamps, and connection hardware, it is ideal for pole and line installation processes.
Structural Overview (Typical)
  • Conductor: Aluminum stranded conductor (optional: steel wire reinforcement for increased tensile strength)
  • Insulation: Cross-linked polyethylene (XLPE)
  • Optional Outer Layer: Depends on the project (some specifications may include a protective sheath)
  • Core: Overhead lines typically use single-core conductors
  • Installation Method: Overhead, secured to poles/towers using specialized hardware
Process and Manufacturing Notes
  • Conductor Stranding
  • Aluminum stranded wire is stranded to achieve the required conductivity and flexibility; a steel core can be added as needed to increase tensile strength.
  • Insulation Extrusion
  • XLPE insulation is extruded with controlled thickness and concentricity to ensure the performance of overhead power systems.
  • Crosslinking and Curing
  • XLPE is crosslinked to improve its thermal and mechanical stability.
  • Surface and Marking
  • Surface quality and continuous marking are controlled to ensure traceability, installation identification, and project acceptance.
  • Routine Inspections
  • Typical inspection items include conductor resistance, insulation thickness, spark/voltage tests according to applicable standards, and dimensional inspections.
Common Specifications Overview (Most Common)

Core Wire Type: Single-core Overhead Conductor

Common Conductor Structures (Examples): Aluminum Stranded Wire, Aluminum-Steel Composite Wire (Depending on the Project)

Common Cross-sectional Area (mm²): 10 16 25 35 50 70 95 120 150 185 240 300 400

Common Bill of Quantities Items (Examples)
  • 1 core x 50 mm²
  • 1 core x 70 mm²
  • 1 core x 95 mm²
  • 1 core x 120 mm²
  • 1 core x 150 mm²
  • 1 core x 185 mm²
  • 1 core x 240 mm²
  • 1 core x 300 mm²
Specifications (can be copied directly)
Attribute Value
Product Model JKLGYJ
Product Category Overhead Insulated Conductor (Sheathed Conductor) Distribution
Typical Voltage Rating 10kV (Please confirm required rated voltage and standard)
Conductor Material Aluminum Stranded Wire (Optional: Steel Core Aluminum Stranded Wire)
Insulation Cross-linked Polyethylene (XLPE)
Number of Cores 1 Core
Typical Size Range 10 to 400 mm² (depending on project)
Typical Applications Overhead distribution lines, rural electrification, vegetated corridors, long-span overhead lines
Installation Method Overhead, secured to poles/towers using matching clamps and accessories
Packaging Reel (standard packaging for overhead conductors)
Optional Configurations Conductor structure, insulation color, marking language, reel length diagram, accessory kit, inspection support, documentation kit
Buyer Selection Checklist
  • Confirm the rated voltage rating and applicable standards for your market
  • Confirm conductor type: All aluminum or steel core (tension/span requirements)
  • According to Confirm load current, line loss, and line route cross-sectional area length.
  • Confirm voltage level and required insulation thickness for the environment.
  • Confirm installation environment: coastal corrosion, high altitude, strong winds/freezing.
  • Confirm accessory package: lifting clamps, terminal blocks, connectors, protective accessories.
  • Confirm drum length and cutting scheme to reduce the number of joints and speed up construction.
  • Confirm documents required for power company acceptance and project handover.
Quick Inquiry Template
Product:
JKLGYJ
Rated Voltage Rating:
__
Applicable Standards/Specifications:
__
Conductor Type:
Aluminum/Steel Cored Aluminum Stranded Wire
Cross-section and Quantity:
__
Total Length (meters):
__
Line Notes:
Urban/Rural/Vegetated/Large Span/Coastal/Mountainous
Insulation Color Requirements:
__
Packaging:
Drum, Preferred Drum Length: __
Required Documents:
__
Destination:
Country and Port: __
Frequently Asked Questions
Question 1: What is JKLGYJ mainly used for?
Answer: Mainly used for overhead distribution lines, where covered conductors are used. Compared to bare conductors, JKLGYJ is better suited for improving line safety and reducing the risk of failure.
Q2 Is JKLGYJ suitable for long-span lines?
A Many projects choose reinforced conductors for long-span and high-tension lines. Span requirements, sag requirements, and mechanical loads must be confirmed during the design phase.
Q3 What is the insulation material for JKLGYJ?
A Typically, cross-linked polyethylene (XLPE) insulation is used to meet the performance requirements of outdoor overhead lines.
Q4 Can JKLGYJ replace underground medium-voltage cables?
A No. JKLGYJ is primarily used for overhead lines. Underground line systems typically require different cable structures, protection measures, and installation methods.
Q5 What accessories are needed?
A Typical overhead line hardware includes suspension and tension clamps, connectors, and line protection accessories. Specific configurations depend on pole design, span, and local power company specifications.
Q6 What information is needed for an accurate quote?
A requires the following information: rated voltage level, conductor structure (with or without reinforcement), specification list, total length in meters, roll diagram, destination, standard requirements, and necessary documentation.
Service of JinHong Company
Over Productions Service:

JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.

Quality Certification Services:

JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.

Profession Customer Service:

JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.

Delivery And Shipping Services:

While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.

Packaging of JinHong:

JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.