| Brand Name: | JinHong |
| Model Number: | WDZN-YJY |
| MOQ: | 100m |
| Price: | 11.15-16.25USD |
| Payment Terms: | T/T |
Low Smoke Zero Halogen • Fire Resistant • XLPE Insulation • PE Sheath • Non-Armored
WDZN-YJY is a dual-protection safety cable built for projects where cables must not only stop burning, but also stay operational during fire conditions.
Designed for non-direct-burial installations in ultra-high safety environments—such as high-rise towers, hospital operating areas, metro lines, airports, and emergency centers—this cable combines:
Engineered to meet stringent codes including GB/T 19666, GB 12666, GB/T 12666.6, it is tailored for projects facing the toughest fire safety acceptance checks.
| Code | Component | Function & Safety Advantage |
|---|---|---|
| WDZ | Low Smoke Zero Halogen Flame-Retardant System | Halogen-free, low-smoke formulation. Under fire, smoke density stays low (≤50%) and no corrosive halogen acid gases are released. Helps prevent flame spread and limits damage to people and equipment. |
| N | Fire-Resistant Function | Indicates fire-resistance capability in line with GB/T 12666.6 Class N. Maintains circuit integrity for approximately 90 minutes at 750°C. |
| YJ | Cross-Linked Polyethylene (XLPE) Insulation | Supports continuous operation at 90°C with high insulation resistance (≥100 MΩ·km). Low dielectric loss improves transmission efficiency. |
| Y | Polyethylene (PE) Sheath | Environmentally friendly, non-toxic outer layer with strong resistance to UV, weathering, and low temperatures. |
WDZN-YJY doesn't just slow fire; it's designed to keep critical systems energized:
Tailored for projects where fire inspections must be passed on the first attempt:
| Cores * Section (mm²) | Conductor Material | XLPE Insulation (mm) | PE Sheath (mm) | Fire-Resistant Layer (mm) | Approx. Outer Diameter (mm) | Rated Voltage (kV) | Approx. Weight (kg/km) | DC Resistance at 20°C (Ω/km) | Fire Resistance (GB/T 12666.6) |
|---|---|---|---|---|---|---|---|---|---|
| 3 * 10 + 1 * 6 | High-purity copper | 1.0 | 1.8 | 0.5 | 25.8 | 0.6/1 | 420 | ≤ 1.83 | 750°C * 90 min |
| 3 * 16 + 1 * 10 | High-purity copper | 1.0 | 1.8 | 0.5 | 29.2 | 0.6/1 | 560 | ≤ 1.15 | 750°C * 90 min |
| 3 * 25 + 1 * 16 | High-purity copper | 1.2 | 2.0 | 0.6 | 33.8 | 0.6/1 | 780 | ≤ 0.74 | 750°C * 90 min |
| 3 * 50 + 1 * 25 | High-purity copper | 1.4 | 2.2 | 0.6 | 42.3 | 0.6/1 | 1320 | ≤ 0.38 | 750°C * 90 min |
| 4 * 120 | High-purity copper | 1.6 | 2.5 | 0.8 | 53.5 | 0.6/1 | 2450 | ≤ 0.16 | 750°C * 90 min |