ZR-YJV22 XLPE Armored Cable 12/20kV Fire Resistant Cable For Underground
Product Summary
Product Details
ZR-YJV22 XLPE Armored Cable
,XLPE Armored Cable 12/20kV
,12/20kV Fire Resistant Cable
Product Description
ZR-YJV22 Flame-Retardant Armored XLPE Power Cable 0.6/1kV for Underground
ZR-YJV22 is a low-voltage copper core power cable that combines flame-retardant properties with steel tape armor, providing enhanced mechanical protection in fixed installations. This cable is commonly used in lines requiring increased fire safety and protection against compression and external stresses, such as underground conduits, trenches, cable corridors, building inlets, and industrial distribution lines. The cable typically features copper conductors insulated with cross-linked polyethylene (XLPE) and an outer sheath system that meets the relevant standard flame-retardant rating requirements.
For cross-border sourcing, ZR-YJV22 is positioned as a practical "fire safety + line protection" low-voltage feeder cable suitable for contractors and EPC purchasers working on infrastructure, public building, and industrial site projects.
Typical rated voltage: 0.6/1 kV
Please confirm the flame-retardant rating required in your project standards and Bill of Quantities (BOQ).
- 1C for high-current feeders and phase-by-phase installations (depending on the project)
- 2C for dedicated single-phase circuits
- 3C for three-phase circuits without a neutral conductor (depending on the project)
- 4C for three-phase distribution with a neutral conductor
- 5C for three-phase distribution with a neutral conductor and physical earth (PE) protection (depending on the project)
- 3+1 and 3+2 are used in many commonly used feeder configurations (depending on the project)
1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400
- 4C x 10
- 4C x 16
- 4C x 25
- 4C x 35
- 4C x 50
- 5C x 10
- 5C x 16
- 5C x 25
- 5C x 35
- 3 cores x 10
- 3 cores x 16
- 3 cores x 25
- 1 core x 95
- 1 core x 120
- 1 core x 150
- 1 core x 185
- 1 core x 240
Suitable in 3+1 and 3+2 configurations according to local practice and Bill of Materials (BOQ).
Availability depends on conductor grade, armor construction, and required standards.
-
Flame retardant rating ensures safer cable laying
Designed to help limit the spread of flame along the cable laying path, thereby improving the safety of risers, corridors, and dense cable laying.
-
Steel tape armor provides mechanical protection
The armor construction improves resistance to compression and external pressure, enhancing the reliability of underground conduits, trenches, and protected corridors.
-
XLPE Insulation Ensures Stable Low-Voltage Feeder Performance
XLPE insulation provides reliable dielectric strength and thermal properties under continuous load.
-
A Balanced Solution for Infrastructure and Industrial Projects
A viable upgrade option when standard unarmored flame-retardant cables fail to meet line conditions.
-
Easy for EPC Contractors
Common sizes, standardized construction, and reel designs facilitate bill of materials matching, phased delivery, and predictable field installation planning.
- Underground power distribution in conduits and trenches
- Building incoming lines and main low-voltage distribution lines
- Cable corridors, utility passageways, and protected tunnels
- Industrial sites with external pressure risks along cable lines
- Fixed installations requiring flame retardant ratings and armor protection
-
Copper Conductor Production
Copper is drawn and stranded to the specified conductor grade to meet resistance targets and provide suitable installation flexibility.
-
XLPE Insulation Extrusion and Crosslinking
XLPE is extruded and crosslinked to form a stable low-voltage dielectric layer.
-
Core Identification and Wiring
Insulated cores are identified and laminated in a controlled geometry; fillers and adhesives are used to maintain roundness and dimensional stability.
-
Side Layer Formation
Side layers are laid to protect the cores and provide a smooth base for the armor layers.
-
Steel Tape Armoring
Steel tape is wound in a controlled overlap pattern, primarily providing mechanical protection against compression and external pressure.
-
Flame-Retardant Outer Sheath Extrusion
A sheath compound system that meets the required standard flame retardancy rating is selected, processed, and then extruded at a controlled thickness.
-
Routine Testing and Compliance Checks
Typical checks include conductor resistance, insulation thickness control, spark testing, voltage testing, dimensional verification, and sheath integrity checks. Flame retardancy verification is performed according to the required rating.
- Conductor:
- Copper
- Insulation:
- Cross-linked Polyethylene (XLPE)
- Armor:
- Steel tape armor (22 structure, specific standard subject to change)
- Outer Sheath:
- Flame-retardant composite material (specific standard subject to change)
- Installation Method:
- Fixed, including underground conduits and protected wiring
| Attribute | Detail |
|---|---|
| Model | ZR-YJV22 |
| Cable Category | Flame-retardant armored XLPE power cable |
| Rated Voltage | 0.6/1 kV |
| Conductor | Copper stranded wire (grade subject to change) |
| Insulation | Cross-linked Polyethylene (XLPE) |
| Armor | Steel tape armor (22 structure) |
| Sheath | Flame-retardant composite material |
| Core Configuration | 1 core, 2 cores, 3 cores, 4 cores, 5 cores, 3+1, 3+2 |
| Common Cross-sectional Area | 1.5 to 400 mm² |
| Typical Maximum Operating Temperature | Up to 90°C (XLPE) (Design, specific standards depend on the situation) |
| Typical installation methods | duct, trench corridor, riser, protected fixed wiring |
| Packaging | Most sizes are packaged in reels, smaller sizes in coils |
| Optional services | Markup language, packaging marking, reel planning, documentation |
- When the project requires flame-retardant low-voltage feeder cable with steel tape armor protection for underground or mechanically sensitive lines, please select ZR-YJV22.
- Confirm the flame retardancy rating required by the reference standard.
- Select the number of cores based on the distribution scheme and neutral/protection layer requirements.
- Select the cross-sectional area based on current, line length, grouping, ambient temperature, and allowable voltage drop.
- If the line also requires low-smoke halogen-free, specify low-smoke halogen-free armored cable instead of the standard ZR sheath system.
- Product:
- ZR-YJV22
- Voltage:
- 0.6/1 kV
- Flame Retardant Requirement:
- Complies with Standard__
- Core Wire Configuration:
- __
- Cross-section List:
- __ mm²
- Total Quantity:
- __ meters
- Installation Path:
- Conduit/Trench/Corridor/Building Inlet
- Required Standard:
- __
- Destination:
- Country and Port__
- Trade Terms:
- __
- Special Requirements:
- Sheath Requirements, Markings, Reel Length, Inspection Documents
- What is ZR-YJV22 used for?
- It is used for low-voltage power distribution lines that require a flame retardant rating and steel tape armor for line protection, commonly found in conduits, trenches, corridors, and building inlets.
- What does 22 construction usually represent?
- In many market practices, it indicates a steel tape armored construction designed to improve resistance to compression and external pressure; specific requirements are subject to reference standards.
- What is the difference between ZR-YJV22 and ZR-YJV?
- ZR-YJV22 features added steel tape armor for mechanical protection, while ZR-YJV is typically unarmored. Both meet the flame retardancy requirements of relevant standards.
- Can ZR-YJV22 be used for direct burial?
- It is typically used in conduits and trenches. The suitability for direct burial depends on soil conditions, mechanical risks, and local requirements. Please provide detailed installation route information for proper selection.
- What sizes are commonly used by contractors?
- 10 to 50 mm² 4-core and 5-core cables are commonly used for building distribution, while 95 to 240 mm² 1-core cables are commonly used for high-current feeders.
- What information is needed for a quote?
- Flame retardancy rating, core configuration, cross-sectional area, total length, required standards, installation route, packaging requirements, and destination.
-
Over Productions Service:
JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.
-
Quality Certification Services:
JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.
-
Profession Customer Service:
JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.
-
Delivery And Shipping Services:
While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.
JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.