products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Control Cable
Created with Pixso.

KVV Multi-Core Control Cable – Reliable Signal & Control Wiring for Industrial

KVV Multi-Core Control Cable – Reliable Signal & Control Wiring for Industrial

Brand Name: JinHong
Model Number: KVV
MOQ: 100m
Price: 5.15-12USD/m
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Jacket Thickness:
0.381mm
Rated Voltage:
600/1000V
Sample:
Free
Productname:
Control Cable
Number Cores:
Muulti-core
Constructure:
7x7
Jacket Material:
PVC
Warranty:
10 Years
Voltage:
0.6/1kv
Insulation:
Special PVC
Sheath Color:
Black Or As Per Requirement
Color:
Black Or Customized
Specification:
61x2.5 Mm2
Core Number:
3 Core, 2 Core To 37 Core
Voltage Rating:
150V
Highlight:

pvc control cable

,

pvc multicore shielded cable

Product Description
1. Core Content and High-Conversion Marketing Proposition
KVV Industrial Control Cables – Stable Signal Transmission + Durable PVC Sheath, Supporting the Development of Global Industrial Automation Systems
  • Reliable Control Signal Transmission
  • Oil and Abrasion Resistant
  • Suitable for Control Panels
  • All-Weather Adaptability
  • Perfect for Factory Automation, Control Cabinets, and Instrumentation

Industrial control systems rely on stable signal transmission, but ordinary cables often suffer from signal distortion, sheath wear, and environmental damage, leading to control system failures and production downtime. KVV's dedicated PVC-insulated control cables, designed for specific control systems and made with robust and durable materials, are designed to solve these pain points. The cable uses high-purity Category 1/2 stranded copper conductors, PVC insulation, and a reinforced PVC outer sheath to ensure stable low-voltage signal transmission, resistance to industrial oils and abrasion, stable operation in a temperature range of -30°C to 70°C, and adaptability to complex industrial wiring. Certified to EU (CE/RoHS 3.0), North American (UL 1277), Australian (SAA), and Middle East & North Africa (SASO) standards, KVV cables are the trusted choice for manufacturing plants, automation engineers, and control system integrators worldwide.

2. What is a KVV cable?

KVV is a high-quality low-voltage (0.45/0.75kV) dedicated control cable designed for signal transmission and control command delivery in industrial automation systems, used to connect control panels, sensors, actuators, and instruments. Its optimized control structure ensures signal integrity: Category 1/2 stranded copper conductors (low resistance, stable signal transmission), PVC insulation (excellent dielectric strength, interference immunity), and a reinforced PVC outer sheath (core protection, oil-resistant, abrasion-resistant, UV-resistant).

"KVV" definition:

K = Control cable (suitable for industrial control scenarios);

V = PVC (polyvinyl chloride) insulation;

V = PVC outer sheath.

Its unique features: Unlike power cables or inverter cables, KVV is designed specifically for low-voltage control signal transmission (not high-power transmission), featuring uniform conductor resistance and low capacitance to avoid signal attenuation. Its flexible structure and durable PVC sheath make it ideal for confined wiring environments such as control cabinets and industrial conduits—crucial for precise control in automation systems.

3. Key Selling Points
Stable Control Signal Transmission:

Utilizing uniform cross-section 1/2-grade stranded copper conductors, signal attenuation is minimized (≤1.5% attenuation over 100 meters for a 1.5mm² cross-section), ensuring accurate transmission of control commands between sensors, actuators, and control panels. In automated production lines, control system error rates are reduced by 50%, making it ideal for precision instruments and process control.

Oil and Abrasion Resistance:

The reinforced PVC outer sheath with special oil-resistant additives resists industrial oils (mineral oils, lubricants), greases, and mechanical abrasion. Passing 10,000 cycles of abrasion testing, it maintains sheath integrity even in high-friction industrial environments (e.g., cable trays, machine tool gaps). No sheath cracking or leakage, with a service life of over 12 years.

Flexible installation for various control scenarios:

Category 2 stranded conductor, minimum bending radius ≤ 6 * cable outer diameter, 30% smaller than standard control cables. Easily maneuvers through narrow control cabinet gaps, cable trays, and around instruments—no special bending tools required, reducing installation time by 40% and significantly improving construction efficiency.

All-weather adaptability (-30℃ to 70℃):

The PVC sheath is formulated with antifreeze and UV resistance. Reliably operates in a variety of environments, including polar industrial control rooms at -30℃, high-temperature workshop control systems at 70℃, desert manufacturing plants at 60℃, and coastal industrial facilities. Resistant to moisture, dust, and weak acids/alkalis, suitable for most industrial environments without additional protection.

Global industrial control certifications and compliance:

CE/RoHS 3.0 (EU, compliant with EN 50200 and IEC 60228 standards), UL 1277 (North America, compliant with NFPA 70 NEC standards), SAA (Australia/New Zealand), SASO (Middle East and North Africa) certifications. We provide customized control system compliance documentation (e.g., signal transmission test reports, industrial safety certificates) for target markets to ensure smooth project approval. Popular specifications are readily available (3-day fast shipping) to support emergency automation upgrades.

4. Commonly Selling Specifications
Model Common Core Count Common Conductor Cross-sectional Area (mm²) Rated Voltage Long-Term Operating Temperature Main Performance Standards Main Certifications Hot-Selling Markets
KVV (Global Industrial Control Grade) 4,5,6,7,8,10,12,14,16 0.75,1.0,1.5,2.5 0.45/0.75kV 70℃ IEC 60228 Class 2, IEC 60332-1-2, Stable Signal CE, RoHS 3.0, IEC 60228 EU, Western Europe, Asia
KVV (UL Automation Control Type) 4,5,6,7,8,10 1.0,1.5,2.5,4 600V 70℃ UL 1277, UL 1685, Control Signal Compatibility UL, cUL, RoHS 3.0 North America, Mexico
KVV (Abrasion-resistant Industrial Grade) 4, 5, 6, 8, 10 1.5, 2.5, 4, 6 0.45/0.75kV 70℃ IEC 60228 Class 2, Enhanced Abrasion-resistant Sheath CE, UL, SAA, RoHS 3.0 Global Heavy Duty Manufacturing

Note: All specifications are in stock (fast shipping within 3 days). Bulk orders can customize the number of cores (up to 37 cores) and cross-section (0.75~6mm²), ensuring signal stability, durability, and regional certification. Cores are color-coded for easy signal identification.

5. Application Scenarios for Specific Geographic Regions

KVV cables are specifically designed to meet the control signal transmission needs of industrial automation projects worldwide, covering application scenarios in regions with high compliance requirements:

EU Market:

Factory automation production line control, CNC machine tool instrumentation cables, water treatment plant control panels, pharmaceutical production process control (compliant with CE/RoHS 3.0 standards, and meets EN 50200 and IEC 61131-2 control system standards)

North American Market:

Automotive manufacturing assembly line control, HVAC building automation systems, food processing equipment instrumentation, industrial robot control cabinets (UL 1277 certified, compliant with NFPA 70 NEC and IEEE 61010 instrumentation standards)

Australia and New Zealand:

Mining equipment control systems, coastal manufacturing plant control panels, agricultural machinery automation, remote industrial instrumentation (compliant with SAA standards) Certifications: Salt spray resistant, inland high temperature resistant, mine dust resistant

Middle East and North Africa Market:

Desert petrochemical plant control systems, oil and gas field instrumentation cables, smart factory automated production line plastic processing equipment control panels (SASO certified, heat resistant, sand resistant, oil resistant)

Global Industrial Control:

Power plant auxiliary system control, port crane control cabinets, textile mill process control, packaging machinery instrumentation (stable signal transmission, compatible with all mainstream control systems)

6. Frequently Asked Questions
What is the difference between KVV and KVVP control cables?

KVV has no shielding layer (suitable for general control scenarios with low interference); KVVP adds a copper wire braided shielding layer (suitable for high-interference environments such as near frequency converters). KVV prioritizes cost-effectiveness and stable signal transmission, suitable for general industrial control; KVVP prioritizes anti-interference performance, suitable for complex automation environments.

Can KVV be used for outdoor control system installation?

Yes. Its UV-resistant PVC sheath is suitable for outdoor control scenarios (e.g., outdoor water pump control, solar power plant auxiliary control). For long-term outdoor use in areas with heavy rain or high humidity, we recommend the KVV-OW model, specifically designed for outdoor environments and featuring an enhanced waterproof sheath.

What is the maximum control signal transmission distance for KVV cables?

For 1.5mm² cross-section cables, the stable signal transmission distance is up to 200 meters; for 2.5mm² cross-section cables, it is up to 300 meters. For distances exceeding 300 meters, we recommend increasing the conductor cross-sectional area or using our low-loss KVV-LD model with optimized insulation to reduce signal attenuation.

Are KVV conductors color-coded for easy identification?

Yes. All KVV cable conductors are color-coded (standard colors: black, red, blue, yellow-green, etc.), conforming to IEC 60309 and UL 1277 color standards. This simplifies wiring within control cabinets and reduces installation errors—custom color coding can also be provided for bulk orders based on project requirements.

What is the minimum order quantity (MOQ) for custom KVV core counts?

The MOQ for custom core counts (e.g., 18 cores, 24 cores) is 600 meters per specification. For urgent small-batch custom orders (300-600 meters), we offer priority production service. For a small surcharge, we guarantee delivery within 10 working days to meet your control system construction schedule requirements.

Is KVV compatible with PLC (Programmable Logic Controller) systems?

Fully compatible. It is fully compatible with major global PLC brands (Siemens, Rockwell Automation, Mitsubishi, Omron). Stable signal transmission ensures accurate communication between the PLC and field devices. We provide PLC system compatibility test reports for bulk orders.