Flexible YJVR Cable 0.6/1KV PVC Insulation Cable Copper Conductor

Flexible YJVR Cable 0.6/1KV PVC Insulation Cable Copper Conductor

Brand Name: JinHong
Model Number: YJVR
MOQ: 100m
Price: 1.15-2.55USD
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Conductor Material:
Copper
Insulation Material:
PVC
Application:
Underground,Industrial,Construction,overhead,Power Station
Jacket:
PVC,Non,no Jacket,PVC Or XLPE,PVC/PE
Insulation Material:
XLPE,PVC,Rubber,XLPE(XLPO),xlpe Or Pvc
Conductor Material:
Copper,Aluminum,steel Core Aluminum Strand,copper/aluminium,tin Plated
Type:
Low Voltage,Medium Voltage,High Voltage,Insulated,Rigid/Flexible Round
Standard:
IEC60502,IEC,BS,UL,JIS
Color:
Black,Red,blue,brown,Requirement
Product Name:
Medium Voltage Power Cable,Fire Resistant 4core LV Armoured Electrical Cable XLPE Copper Cable,XLPE PVC Insulated PVC Sheathed 4 Core Copper Power Cable,steel Tape Armoured Cable,Aerial Bundled Cable
Conductor:
Copper,Alulminum,Class 2 Annealed Copper Strands,Cu / Al,strand
Insulation:
XLPE,XLPE PE PVC,PVC,PE,XLPE/PE/PVC
Rated Voltage:
0.6/1KV,3.6~35kv,8.7/10,3.6/6.6,6/10
Voltage:
0.6/1KV,low Voltage,medium Voltage,300/500V,450/750V
Core:
1 Core,5 Core,duplex/triplex/quadruplex,3,Single
Sheath:
PVC,ZR-PVC,LSOH,Non-sheath,PE
Packing:
Wooden Drum,optional,Wooden-steel Drum
Conductor Type:
Stranded,copper
Name:
11KV SWA FIRE RETARDANT CABLE,welding Cable,JKLGYJ 1KV Overhead Power Cables
Armour:
Steel Wire Or Aluminum Wire Armor,Steel Tape Armour,STA/SWA/ATA/AWA,or Unarmored
Item:
XLPE Copper Cable,Medium Voltage XLPE Cable
Highlight:

Flexible YJVR Cable

,

YJVR Cable 0.6/1KV

,

0.6/1KV PVC Insulation Cable

Product Description
YJVR Flexible Power Cable Copper Conductor PVC Insulation Industrial Applications
Factory Direct Sale VVR YJVR RVVZ Copper Core Soft Wire Cables
YJVR is a Flexible XLPE Insulated PVC Sheathed Power Cable with stranded copper conductors, designed for applications requiring flexibility, reliability, and ease of installation.
Cable Designation Breakdown
  • YJ: XLPE (Cross-Linked Polyethylene) Insulation
  • V: PVC Sheath
  • R: Flexible (Stranded Copper Conductor)
Applications
  • Industrial Machinery: Connections to motors, pumps, and portable equipment requiring movement
  • Temporary Power Supply: Construction sites, event stages, and exhibition centers
  • Renewable Energy Systems: Wiring for solar panels and wind turbines where flexibility is needed
  • Building Services: Flexible power connections in commercial and residential buildings
Key Advantages
  • High Flexibility: Ideal for applications requiring frequent movement or tight bends
  • Reliability: XLPE insulation ensures stable performance under high loads and varying temperatures
  • Ease of Installation: Lightweight and pliable, reducing installation time and effort
  • Cost-Effective: Balances performance and affordability for dynamic power needs
YJVR is suitable for dynamic and fixed low-voltage applications where flexibility is critical. For enhanced fire safety, consider NH-YJVR (fire-resistant) or WDZ-YJVR (LSZH) variants. Customizable conductor sizes (1.5-300 mm²) and core counts (1-5 cores) are available. Consult technical datasheets for details.
Technical Specifications
Number of Cores Conductor Cross-Sectional Area (mm²) Cable Outer Diameter (mm) Reference Weight (kg/km)
4+1 4*4+1*2.5 14.2 320
4+1 4*6+1*4 15.6 427
4+1 4*10+1*6 18.1 636
4+1 4*16+1*10 20.8 940
4+1 4*25+1*16 24.9 1441
4+1 4*35+1*16 27.1 1853
4+1 4*50+1*25 31.6 2616
4+1 4*70+1*35 36.5 3578
4+1 4*95+1*50 44.3 4843
4+1 4*120+1*70 48.3 6110
4+1 4*150+1*70 51.2 7421
4+1 4*185+1*95 56.8 9191
4+1 4*240+1*120 63.2 11763
4+1 4*300+1*150 70.0 14995
Flexible YJVR Cable 0.6/1KV PVC Insulation Cable Copper Conductor 0
Frequently Asked Questions
What does the "YJVR" cable designation specify?
"YJVR" is a Chinese cable model code. Typically, it denotes a flexible, PVC-insulated and sheathed control cable with copper conductors. "YJ" often indicates cross-linked polyethylene (XLPE) insulation, "V" represents PVC sheath, and "R" signifies flexible/stranded conductors. It is designed for fixed installation in dry or damp indoor environments, conduits, or cable trays.
What are the standard voltage ratings and conductor specifications for YJVR cables?
Standard rated voltage is typically 450/750V. Conductors are made of annealed copper (Class 5 stranded for flexibility) and are available in a standard range of cross-sectional areas, commonly from 0.75 mm² up to 10 mm² or 16 mm², with multiple cores (e.g., 2 to 61 cores, depending on the manufacturer's product line).
What is the temperature range for operation and installation?
The long-term maximum permissible operating temperature for the conductor is usually +70°C. The minimum installation temperature is typically -15°C to prevent damage to the insulation and sheathing during handling in cold conditions.
In what applications is the YJVR cable commonly used?
It is primarily used for electrical connection and control circuits in industrial plants, machinery, instrumentation systems, and building automation where medium flexibility is required. Common applications include connections to motors, control panels, sensors, and various electrical equipment in stationary installations.
What are the key differences between YJVR and other common control cables like KVVR or RVV?
The key difference often lies in the insulation material. YJVR uses cross-linked polyethylene (XLPE), which offers better thermal stability, higher resistance to heat deformation, and slightly better electrical properties compared to the PVC insulation used in standard KVVR or RVV cables. This makes YJVR suitable for environments with slightly elevated ambient temperatures.
Is the YJVR cable flame retardant?
The standard PVC sheath offers a degree of flame retardancy. For applications requiring enhanced fire safety, look for specific variant designations like "YJVR-ZR" or "YJVR-B," which indicate halogen-free, low-smoke, and flame-retardant (LSZH) or fire-resistant constructions, respectively. Always verify the exact specification with the manufacturer's datasheet.
Can YJVR cable be used for outdoor or buried installations?
Generally, no. The standard PVC sheath is not designed for prolonged exposure to direct sunlight (UV), extreme weather, or direct burial. For outdoor use, a cable with a UV-resistant and weatherproof sheath (like specific outdoor-grade PVC or PE) is required.
How do I verify the certification and compliance of a YJVR cable?
Reputable manufacturers should provide proof of compliance with Chinese national standards (GB standards). Key standards include GB/T 9330 for control cables. For international projects, check if the cable also holds certifications like CE, RoHS, or meets equivalent IEC standards (e.g., IEC 60227). Always request the official certification documents.
Flexible YJVR Cable 0.6/1KV PVC Insulation Cable Copper Conductor 1 
Service of JinHong Company
 
Over Productions Service: 
 
JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.
 
Quality Certification Services:
 
 JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.
 
Profession Customer Service:
 
JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.
 
Delivery And Shipping Services:
 
While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.
 
Packaging of JinHong:
 
JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.