products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Electrical Cable Wire
Created with Pixso.

450 750V Copper Conductor Cable Core Pvc Insulation Flexible Twisted Pair Wire RVS

450 750V Copper Conductor Cable Core Pvc Insulation Flexible Twisted Pair Wire RVS

Brand Name: JinHong
Model Number: RVS
MOQ: 100m
Price: 0.56-0.99USD
Payment Terms: T/T
Detail Information
Place of Origin:
Anhui China
Certification:
CCC
Conductor Type:
Stranded,Solid,Solid/Flexible
Conductor Material:
Copper,etc.,Fiberglass With Nichrome Wire,solid Or Stranded Tinned Copper,Copper | Tinned Copper
Application:
Heating,Electric Conduction,Lights And Lamps,Electric Appliance,AWM Appliance Wiring Material
Type:
Insulated,Bare
Insulation Material:
Rubber,PVC,Silicone,fiber Glass,XLPE
Color:
Requirement,Yellow,can Be Customized,red Black,White/Blue/Red/Black/Brown/Yellow/Green/Transparent
Rated Voltage:
600V,300/500V,300/500V 450/750V
Product Name:
Copper Core PVC Insulation Wire,DIY Silicone Wire,anchor Silicone Copper Electric Wire 220v 3 Wire Flat Cable,silicone Rubber Electrical Wire Cable For Neon Lighting,XLPE Irradiation Wire
Conductor:
Copper Core,Tinned Copper,fiberglass Nichrome Conductor Wire,Stranded Copper,Silver & Tinned & Nickel Copper
Insulation:
Silicone Rubber,Silicone Insulation,PVC Insulation Cable,PVC,XLPE
Size:
Optional,18awg/22awg,30AWG - 4/0AWG,24awg~12awg,2-30
Rated Temperature:
200,-60C-+200C,+200℃,-60~ 200,-60'C ~ + 180'C
Packing:
305meters Per Roll,100m/roll,100 Pieces / Bag,305/610m Per Roll,optional
Material:
Silicone Rubber,silicone Wire,High Purity Copper,Tinned Copper
Standard:
UL758,IEC 60227,GB IEC JIS NEMA,IEC60502
Temperature:
150 Degree,-60℃ To 200℃,200degree,-60C~+150C
Length:
Optional,100mm,Customized Length,610m
Usage:
Heating Element,Indoor,Heating Product
Test Voltage:
3000V
Highlight:

450 750V Copper Conductor Cable

,

Flexible Twisted Pair Wire RVS

,

450 750V Twisted Pair cable

Product Description
RVS 2*2.5mm² Flexible Twisted-Pair Cable
RVS Cable is a PVC-insulated flexible stranded copper pair cable designed for low-voltage electrical connections, signaling, and control circuits. The cable's construction provides excellent flexibility and basic electromagnetic interference protection.
Cable Construction Breakdown
  • R: Flexible Stranded Copper Conductor
  • V: PVC Insulation
  • S: Twisted Pair Structure
Key Applications
  • Signaling Systems: Fire alarms, security systems, and intercoms
  • Control Circuits: Automation systems, sensors, and PLC wiring
  • Low-Voltage Lighting: LED lighting and decorative fixture connections
  • Home Appliances: Internal wiring for household devices
Product Advantages
  • EMI Reduction: Twisted pair structure minimizes signal interference
  • High Flexibility: Ideal for applications requiring frequent bending or movement
  • Cost-Effective: Affordable solution for low-voltage signaling and control
  • Easy Installation: Lightweight and simple to handle during installation
    Nominal section(mm²) Number/diameter of core(mm) Maximum outer diameter(mm) Reference weight(kg/km)
    2*0.3 2*16/0.15 4.3 12.8
    2*0.4 2*23/0.15 4.6 16.2
    2*0.5 2*28/0.15 5.8 22.9
    2*0.75 2*42/0.15 6.2 29.6
  • 450 750V Copper Conductor Cable Core Pvc Insulation Flexible Twisted Pair Wire RVS 0450 750V Copper Conductor Cable Core Pvc Insulation Flexible Twisted Pair Wire RVS 1
  • 450 750V Copper Conductor Cable Core Pvc Insulation Flexible Twisted Pair Wire RVS 2
Note: RVS cable is suitable for low-voltage applications where flexibility and EMI reduction are important. For enhanced fire safety, consider NH-RVS (fire-resistant) version, or for outdoor use, RVS with additional protection. Customizable conductor sizes (2*0.5mm² to 2*2.5mm²) available. Consult technical datasheets for detailed specifications.
Frequently Asked Questions
What does RVS cable stand for?
RVS designation breakdown:
  • R: Flexible stranded copper conductor
  • V: PVC (Polyvinyl Chloride) Insulation
  • S: Twisted pair (or Stranded pair) structure
RVS is a flexible, PVC-insulated, twisted-pair cable primarily used for low-voltage signal transmission and control circuits.
What is the main advantage of the twisted pair design?
The twisted pair structure provides basic protection against electromagnetic interference (EMI) and crosstalk. By twisting the two conductors together, external electrical noise affects both wires similarly, helping to cancel it out and ensure cleaner signal transmission for sensitive circuits like alarms or controls.
What is the standard voltage rating for RVS cable?
The standard voltage rating is 300/300V. This classifies it as a low-voltage cable, making it unsuitable for main power distribution but ideal for signaling, control, and low-power applications.
Where is RVS cable commonly used?
  • Fire Alarm & Security Systems: Wiring for smoke detectors, call points, and sensors
  • Intercoms and Doorbell Systems
  • Low-Voltage Lighting Control: Wiring for switches and control panels (e.g., for LED lighting)
  • Building Automation: Connections for sensors, thermostats, and other control devices
  • Internal wiring of household appliances
Can RVS cable be used outdoors or buried directly?
No. RVS cable is designed for indoor, dry locations only. Its PVC insulation and lack of an overall protective sheath make it unsuitable for direct burial, damp environments, or prolonged exposure to sunlight (UV), which would cause the material to degrade.
What is the packaging method for this type of wire?
Stretch Film Packaging
What safety standards does RVS cable comply with?
RVS cable typically complies with international and national standards for PVC-insulated cables, such as:
  • IEC 60227 (International Electrotechnical Commission)
  • GB/T 5023 (Chinese National Standard)
Common certifications include CE (Europe) and CCC (China Compulsory Certification).
What is the temperature range for RVS cable?
  • Operating Temperature Range: Typically -15°C to +70°C
  • Long-term Maximum Conductor Temperature: 70°C
It is important not to install it in environments outside this specified range.
What are the important installation guidelines?
  • Bending Radius: Maintain a minimum bending radius of 6 times the cable diameter to avoid damaging the conductors or insulation
  • Separation from Power Cables: Run RVS cables separately from AC power cables or cross them at a 90-degree angle to minimize interference
  • Use Conduits or Trunking: For added protection in walls, ceilings, or areas with potential mechanical damage
Why should I choose RVS cable for my project?
Choose RVS if you need a cost-effective, flexible cable for reliable low-voltage signal wiring indoors. Its twisted pair design offers a simple solution for reducing electrical noise in control circuits, and its high flexibility makes installation in tight spaces easier than with solid-core wires. For power connections, consider RVV; for outdoor use, look for cables with UV-resistant sheaths.
450 750V Copper Conductor Cable Core Pvc Insulation Flexible Twisted Pair Wire RVS 3
Service of JinHong Company
 
Over Productions Service: 
 
JinHong has a wide range of cable and conductor products for you to choose from. We will provide caring services and professional project solutions for everyone who needs them.
 
Quality Certification Services:
 
 JinHong cable products are manufactured according to GB, IEC, BS, NFC, ASTM, DIN, and other international standards. Our technical team can customize cable products that meet your requirements according to your needs.
 
Profession Customer Service:
 
JinHong provides free professional consulting services to provide you with one-stop project solution services and rapid product delivery solutions.
 
Delivery And Shipping Services:
 
While we at JinHong provide high-quality cables, we also provide good delivery solutions. While ensuring the safe delivery of products, we provide the best packaging and transportation solutions, greatly reducing customers’ transportation costs.
 
Packaging of JinHong:
 
JinHong cable packaging is provided in the form of wooden reels, corrugated boxes, and coils. The cable ends are sealed with BOPP self-adhesive tape and a non-hygroscopic sealing cap to protect the cable ends from moisture. We can print the required marks on the outside of the barrel with waterproof material according to customer requirements.