Câble NH-YJV résistant au feu, câble d'alimentation basse tension isolé XLPE
Core Technical Parameters: Safety and Quality Controllable in All Dimensions Parameter Category Specific Parameters Rated Voltage 0.6/1KV (AC) Conductor Material High-purity oxygen-free copper core (GB/T 3956-2008 Class 2 conductor, conductivity ≥97%) Insulation Material Aging-resistant cross-linked polyethylene (XLPE), temperature resistance 90℃, insulation resistance ≥100MΩ·km Sheath Material Flame-retardant polyvinyl chloride (PVC), oxygen index ≥30%, abrasion resistance
Cable d'alimentation WDZA-YJY XLPE 0,6/1KV Sous-sol LSZH Rétardant de flamme
Core Technical Parameters: Green, Intelligent, and Fully Controllable Quality Parameter Category Specific Parameters Rated Voltage 0.6/1KV (AC) Conductor Material High-purity oxygen-free copper core (GB/T 3956-2008 Class 2 conductor, conductivity ≥98%) Insulation Material Halogen-free low-smoke cross-linked polyethylene (XLPE), temperature resistance 90℃, insulation resistance ≥200MΩ·km Sheath Material Anti-aging halogen-free low-smoke polyolefin, oxygen index ≥35%, abrasion
Câble armé Swa 35mm 50mm 70mm 95mm WDZB-YJY Câble d'alimentation gainé PVC
Why WDZB-YJY Is the Preferred Choice for Global Buyers
Câble d'alimentation à faible émission de fumée et sans halogène, gaine PE, non armé
WDZ-YJY Low Smoke Zero Halogen Power Cable LSZH Flame-Retardant • XLPE Insulation • PE Sheath • Non-Armored Lightweight Design WDZ-YJY is a halogen-free, low-smoke power cable designed for non-direct-burial installations such as conduits, cable trays and overhead routes. It combines a low smoke zero halogen flame-retardant system (WDZ), cross-linked polyethylene insulation, polyethylene outer sheath, and high-purity copper conductors to deliver safer performance in fire
Câbles d'alimentation industriels XLPE robustes 4 conducteurs, câble moyenne tension
Robust XLPE Cable for Transportation & Industrial Automation WDZ-YJY23 armored cable delivers superior performance for electrical wiring in safety-critical transportation infrastructure and industrial automation systems. Four Major Advantages for Safety-Critical Projects 1. LSZH Flame-Retardant System – Fire Safety Without Toxic Gases WDZ-YJY23 is engineered to reduce harm in case of fire: Flame-retardant performance: Self-extinguishes after ignition source removal and
Câble ignifuge sans halogène 11KV, câbles à faible émission de fumée résistants au feu
WDZN-YJY LSZH Fire-Resistant Power Cable Low Smoke Zero Halogen • Fire Resistant • XLPE Insulation • PE Sheath • Non-Armored WDZN-YJY is a dual-protection safety cable built for projects where cables must not only stop burning, but also stay operational during fire conditions. Flame retardant to limit spread • Fire resistant to maintain power • Eco-friendly & non-toxic • Lightweight & easy to install Designed for non-direct-burial installations in ultra-high safety environmen
Le câble WDZ-KYJYRP XLPE LSZH câble de commande blindé
WDZ-KYJYRP LSZH Shielded Flexible Control Cable This low smoke zero halogen shielded flexible control cable is engineered for industrial automation systems, intelligent building networks, and precision equipment control. It delivers stable signals with strong anti-interference capabilities while ensuring safety and easy installation. Key Value Proposition: Flame-retardant & eco-friendly • Shielded & anti-interference • Flexible & easy to install • Accurate & stable signal
Câble de contrôle blindé flexible XLPE avec faible émission de fumée et zéro halogène
WDZ-KYJRP Low Smoke Zero Halogen Shielded Flexible Control Cable Model Decoding - Control-Grade, Shielded, Flexible Design Core Components and Benefits Code Component Meaning & Advantage WDZ Low Smoke Zero Halogen Flame Retardant Smoke density ≤50%, releases no toxic halogen gases. Complies with GB/T 17650 for Class B flame retardancy. Fire-safe with low corrosiveness, preventing the spread of fire. K Control Cable Specifically designed for low-voltage signal transmission (0
BPYJVP2 câble de conversion de fréquence recouvert de PVC pour équipement d'onduleur pétrochimique
Core Technical Parameters · Precision Quality, Data Support Parameter Category Specifications Rated Voltage 0.6/1kV (AC) Conductor Material Category 5 ultra-fine flexible copper conductor (compliant with GB/T 3956-2008 standard) Insulation Material Cross-linked polyethylene (XLPE) — withstands 90℃, excellent pulse voltage withstand Sheath Material Polyvinyl chloride (PVC); optional halogen-free low-smoke polyolefin flame-retardant sheath Shielding Structure Copper tape
Le câble de gaine en PVC BPYJVP 30 mm2 50 mm2 95 mm2 Corne de cuivre à tension moyenne
BPYJVP Inverter-Specific Cable Designed for Inverters - Clean Power, Quiet Operation, Continuous Output Modern VFD (Vehicle Frequency Converter) systems place far more demands on cables than simple power transmission. High-frequency switching, harmonic-rich waveforms, and compact industrial layouts increase the risk of interference, overheating, and instability. BPYJVP is a cable specifically designed for VFD/inverter systems of 0.6/1 kV and below, offering enhanced
Câble NH-YJV résistant au feu, isolation XLPE, âme en cuivre, câble basse tension
NH-YJV Fire-Resistant Cross-Linked Polyethylene Cable (0.6/1 kV) Optimized for high-end applications, combining safety, efficiency, and durability. Ensuring power reliability is paramount in today's harsh environments. NH-YJV cables utilize upgraded cross-linked insulation and are nationally fire-certified, providing energy-efficient transmission and making them an ideal solution. Whether you are cabling for advanced data centers, Grade A office buildings, or high-load
Câble LSZH 0.6/1 KV Classe B FR Cuivre XLPE pour alimentation WDZBN-YJY
Core Technical Parameters: Safety, Environmental Protection, and Quality Fully Controllable Parameter Category Specific Parameters Rated Voltage 0.6/1KV (AC) Conductor Material High-purity oxygen-free copper core (GB/T 3956-2008 Class 2 conductor, conductivity ≥98%) Insulation Material Halogen-free low-smoke cross-linked polyethylene (XLPE), temperature resistance 90℃, insulation resistance ≥200MΩ·km Sheath Material Anti-aging halogen-free low-smoke polyolefin, oxygen index
Rétardant de flamme 4 mm WDZ-BYJ câble 450/750V sans halogène faible fumée
WDZ-BYJ LSZH Building Wire (450/750V) Low Smoke · Zero Halogen · Flame-Retardant · 90°C Rated — Safer wiring for modern buildings When wiring runs through crowded public spaces, vertical shafts, tunnels, and equipment rooms, the biggest danger in a fire isn’t only flame—it’s smoke density and corrosive/toxic gases. WDZ-BYJ is designed for projects that want a safer evacuation environment and better protection for sensitive equipment, using LSZH (Low Smoke Zero Halogen) cross
3 4 5 Noyau 16 mm 25 mm 35 mm YJV22 câble cuivre aluminium noyau fil électrique
YJV22 Steel Tape Armored Power Cable YJV22 is an XLPE insulated, PVC sheathed, steel tape armored power cable with copper conductors, designed for robust power distribution in environments requiring mechanical protection and reliability. Cable Design Breakdown YJ: XLPE (Cross-Linked Polyethylene) Insulation V: PVC Sheath 22: Double Steel Tape Armor Applications Underground Power Networks: Direct burial in industrial sites, renewable energy farms, and urban infrastructure
4 mm-400 mm XLPE câble isolé en PVC enveloppé YJV 0.6 câble 1KV
YJV XLPE Insulated PVC Power Cable YJV is a XLPE Insulated PVC Sheathed Power Cable with copper conductors, widely used for fixed installations in power distribution networks, industrial plants, and building services. Cable Designation Breakdown YJ: XLPE (Cross-Linked Polyethylene) Insulation V: PVC (Polyvinyl Chloride) Sheath Applications Power Distribution: Underground networks, substations, and grid connections Industrial Wiring: Motors, transformers, and heavy machinery
11KV câble XLPE à noyau unique YJV câble d'alimentation haute tension Norme IEC60502
High Voltage Single Core Copper Conductor Cable YJV XLPE Insulated Cable YJV is an XLPE Insulated PVC Sheathed Power Cable with copper conductors, designed for fixed installations in power distribution networks, industrial plants, and building services. Cable Designation Breakdown YJ: XLPE (Cross-Linked Polyethylene) Insulation V: PVC (Polyvinyl Chloride) Sheath Primary Applications Power Distribution: Underground networks, substations, and grid connections Industrial Wiring:
Cable électrique à haute température 35kv YJLV22 XLPE Cable blindé isolé
Factory Customized YJLV22 Copper Conductor with XLPE Insulation YJLV22 is engineered for superior performance in demanding environments. Featuring high-temperature resistance, cost-effective aluminum conductors, and robust protection against external threats, this cable provides the ideal solution for industrial and residential power transmission projects. Product Features Cross-linked Polyethylene Insulation (XLPE) High Temperature Resistance: Operating up to 90°C with 15%
Câbles d'alimentation industriels YJLV22 avec armure à double ruban d'acier XLPE
YJLV22 Cross Linked Polyethylene Insulated XLPE Cable Designed for superior performance in challenging environments with high-temperature resistance, cost-effective aluminum conductors, and robust protection against external threats. Product Features Cross-linked Polyethylene Insulation (XPE) High Temperature Resistance: Operating up to 90°C with 15% higher transmission efficiency Durability: Anti-aging properties for long-lasting performance Low Loss: Ensures efficient power
Cable blindé YJLHV22 câble enveloppé en PVC XLPE blindé en acier isolé
YJLHV22 Rare-Earth Aluminum Alloy Power Cable – High Performance Lower Investment Code Component Meaning & Performance Advantage YJ Cross-linked Polyethylene (XLPE) Insulation Designed for 90°C continuous operation, low dielectric loss, and excellent anti-aging performance. Transmission efficiency is up to 18% higher than standard insulation. LH Rare-Earth Aluminum Alloy Conductor Alloyed with magnesium and silicon. Conductivity ≥ 62% IACS, surpassing pure aluminum conductors
Cable isolé YJLHV22 XLPE conducteur en alliage d'aluminium de terres rares
YJLHV22 Rare-Earth Aluminum Alloy Power Cable XLPE Insulation • PVC Sheath • Double Steel Tape Armoring YJLHV22 is a next-generation power cable solution built for projects that need strong electrical performance without paying copper prices. By combining rare-earth aluminum alloy conductors with XLPE insulation and double steel tape armoring, it delivers: Higher conductivity than conventional pure aluminum cables Long-term stability and anti-aging performance Significant
WDZ-YJY23 LSZH câble d'alimentation blindé XLPE isolation double protection par ruban adhésif
WDZ-YJY23 Low Smoke Zero Halogen Armored Power Cable LSZH Flame-RetardantXLPE InsulationPE SheathDouble Steel Tape Armoring WDZ-YJY23 is a safety-focused power cable developed for crowded, enclosed and high-standard environments such as high-rise buildings, metro systems, hospitals, and transportation hubs. By combining low-smoke, halogen-free flame-retardant materials with XLPE insulation, a polyethylene outer sheath, and double steel tape armor, it: Minimizes toxic gas and
YJHLV câble non blindé en aluminium XLPE câble en PVC distribution du réseau électrique
YJHLV Rare-Earth Aluminum Alloy Power Cable XLPE Insulation • PVC Sheath • Non-Armored Lightweight Design YJHLV is a specialized aluminum alloy power cable created for non-direct-buried installations such as conduits, overhead lines, and cable trays. By removing the heavy armoring structure while preserving the high-performance aluminum alloy core, it solves three common pain points: Poor conductivity of ordinary pure aluminum cables High material & installation costs of
WDZ-YJY23 Rétracteur de flamme XLPE LSZH câble Double ruban d'acier blindé Sécurité
XLPE Cable Engineered to Prevent Flame Propagation and Molten Dripping with Low Smoke Zero Halogen Flame Retardant Technology Four Major Advantages - Tailored for Safety-Critical Projects LSZH Flame-Retardant System - Fire Safety Without Toxic Gases WDZ-YJY23 is engineered to reduce harm in case of fire: Flame-retardant performance: The cable self-extinguishes after removing the ignition source and is designed to prevent flame propagation and molten dripping. Halogen-free
8.7/15kV câble électrique blindé YJV22 conducteur de cuivre bande blindée en acier
YJV22 Armoured Power Cable Copper Conductor Steel Tape Armor 8.7/15kV Applications YJV22 Armored Power Cable - 8.7/15kV Copper Conductor YJV22 is an XLPE insulated, PVC sheathed, steel tape armored power cable with copper conductors, engineered for robust power distribution in demanding environments requiring superior mechanical protection and reliability. Cable Construction Breakdown YJ: XLPE (Cross-Linked Polyethylene) Insulation V: PVC Sheath 22: Double Steel Tape Armor