High Durability YJLHV22 Cable for Municipal, Industrial & Commercial Power Projects
Product Summary
Product Details
armoured electrical cable for power projects
,YJLHV22 cable high durability
,industrial commercial power cable
Product Description
YJLHV22 is a low-voltage power cable featuring 8000 series aluminum alloy conductors, a low-smoke halogen-free flame-retardant insulation sheath, and a 22-type galvanized steel tape armored structure. Rated at 0.6/1kV, it was specifically developed to meet the dual demands of modern engineering projects in terms of power transmission safety, mechanical protection, environmental protection, and cost control.
Unlike traditional copper and ordinary aluminum cables, this cable boasts superior conductivity, flame retardancy, compressive strength, and climate adaptability. It has passed all standard tests and certifications and is widely used in large-scale municipal infrastructure, high-rise buildings, industrial parks, public transportation hubs, and underground pipeline projects worldwide. As a cost-effective and highly reliable cabling solution, it has become the preferred specification for engineering contractors, electrical designers, and bulk purchasers.
- Conductor: Tightly stranded 8000 series aluminum alloy, optimized alloy formula, enhancing creep resistance, fatigue resistance, and tensile strength.
- Insulation Layer: Low-smoke halogen-free flame-retardant polyolefin, high dielectric stability, heat resistance, and breakdown resistance.
- Inner Sheath: LSZH protective sheath, isolating the internal structure and preventing external friction and moisture damage.
- Armor Layer: Hot-dip galvanized steel strip, rust-proof, impact-resistant, compression-resistant, and tensile-resistant.
- Outer Sheath: Weather-modified LSZH material, UV-resistant, aging-resistant, moisture-proof, and low-temperature resistant.
| Parameter | Value |
|---|---|
| Rated Operating Voltage | AC 0.6/1 kV |
| Long-term Allowable Operating Temperature | ≤ 90°C |
| Maximum Short-Circuit Temperature | 250°C (duration not exceeding 5 seconds) |
| Conductor Cross-Section Range | 10mm²~400mm² |
| Core Type | Single-core, Double-core, Triple-core, 3+1-core, 3+2-core, Multi-core available upon customization |
| Flame Retardant Rating | GB/T 19666 Class A flame retardant, effectively preventing flame spread |
| Smoke Density Performance | Light transmittance ≥70% during combustion, ultra-low smoke emissions |
| Halogen Content | Zero halogens, no corrosive gases released in fire accidents |
| Minimum Bending Radius | Static laying ≥12 times cable outer diameter; Mobile laying ≥15 times cable outer diameter |
| Permissible Ambient Temperature | Above 0°C |
| Overall Tensile Strength | Armored structure improves the overall tensile strength of the cable, suitable for long-distance traction |
| Waterproof Performance | Fully sealed structure, suitable for laying in long-term humid environments |

Standards Compliance
All technical parameters strictly adhere to national GB standards and industry engineering specifications, fully meeting the acceptance requirements of common engineering projects both domestically and internationally.
Categorized by working conditions, laying methods, and project types, covering both conventional and special engineering environments:
- 3.1 Buried and Underground Pipeline Engineering (High Mechanical Pressure)
Suitable for direct burial, pipeline trench laying, integrated utility tunnels, roadbed crossings, and culvert connections. The steel sheath resists soil compression, gravel friction, vehicle vibration, and minor geological displacement. Primarily used for urban power grid renovation, rural power grid upgrades, suburban trunk lines, and municipal pipeline corridor construction.
- High-Standard Public Buildings (Strict Fire Safety Requirements)
Suitable for main power lines and branch circuits in densely populated areas, including high-rise residential buildings, large shopping malls, exhibition halls, Class A hospitals, schools, sanatoriums, hotels, and office buildings. Its low-smoke, halogen-free characteristics meet the highest fire safety standards for public buildings, ensuring safe evacuation in emergencies.
- 3.3 Public Transportation and Transportation Hubs
Suitable for subway stations, train stations, airport terminals, bus stations, and related passageways. Enclosed spaces place higher demands on flame retardancy and smoke suppression, and this cable is perfectly suited to the long-term continuous power supply and complex cable wiring environments of transportation hubs.
- Industrial Production and Warehousing Areas (Harsh On-Site Environments)
Widely used in manufacturing workshops, assembly plants, chemical industrial parks, food factories, pharmaceutical factories, large warehouses, logistics yards, and cold storage facilities. Resistant to equipment vibration, dust corrosion, high humidity, and temperature differences. Halogen-free materials comply with environmental protection and production safety regulations for the light chemical and food industries.
- 3.5 Municipal Landscape and Environmental Protection Projects
Suitable for urban park power distribution, street lighting, landscaping projects, water supply, and sewage treatment projects. The weather-resistant outer layer can withstand long-term outdoor exposure, rain, frost, and ultraviolet radiation; its moisture-proof performance is suitable for water-based infrastructure.
- Indoor and outdoor standard fixed installation
Suitable for cable trays, conduits, and wall installations in factories and buildings. Its good flexibility allows it to adapt to narrow shafts, dense conduits, and multi-turn wiring layouts.
- 4.1 Stable Electrical Performance and Reliable Conductor
The 8000 series aluminum alloy conductor solves common defects of pure aluminum cables such as easy creep, loose wiring, and poor connection stability. Even under long-term full load and frequent current changes, it maintains stable conductivity, preventing overheating at joints. Overall conductivity fully meets engineering design requirements, ensuring continuous and stable power supply.
- 4.2 Class A Fire Resistance and Environmental Performance
Utilizing a full LSZH (Low Smoke Halogen-Free) material system, the cable does not produce toxic or corrosive gases when burning, and produces extremely low smoke. It effectively inhibits flame spread, controls fire transmission, and reduces property damage. The non-toxic and pollution-free materials comply with green building and environmental protection regulations, and will not pollute the soil or air during use and disposal.
- 4.3 Superior Mechanical Protection and Extended Service Life
The galvanized steel tape armor forms a robust protective layer for the cable body, providing excellent resistance to pressure, impact, and friction, effectively preventing damage during construction and long-term operation. The rust-proofing treatment of the steel tape ensures stable protection even in humid environments, significantly extending service life and reducing the frequency of replacements.
- 4.4 All-Weather Adaptability and Anti-Aging Capability
The specially designed outer sheath offers excellent resistance to ultraviolet radiation, ozone, and weathering, allowing for stable operation year-round under various climatic conditions, including high and low temperatures, strong sunlight, heavy rain, and humidity, making it suitable for projects in different climate zones.
- 4.5 Excellent Construction Performance and Efficiency
Compared to copper armored cables, this product is lighter, reducing transportation and handling difficulties. Its optimized structural design provides excellent flexibility and bending performance, facilitating cabling in confined spaces and complex bends, effectively improving overall construction progress and saving labor costs.
- 4.6 Moisture Resistance and Resistance to Weak Chemical Corrosion
The integrated sealed structure effectively prevents moisture penetration. It exhibits a certain degree of resistance to weak acids and alkalis in common soils, maintaining stable performance even in long-term damp underground and semi-outdoor environments.
- 4.7 Significant Overall Cost Advantage
Under the premise of equivalent power transmission performance and safety standards, aluminum alloy materials significantly reduce raw material costs. Combined with low maintenance rates and long service life, this creates higher overall economic benefits for engineering projects.

- 5.1 Design and Model Selection Key Points
- Based on the load current, transmission distance, and project design drawings, select appropriate conductor cross-sectional area and core count to meet actual power requirements.
- For projects with extremely high fire protection standards or fully enclosed space projects, prioritize low-smoke halogen-free flame-retardant cables.
- For areas with harsh geological conditions and frequent external pressure, confirm the integrity of the armor and overall mechanical strength before procurement.
- 5.2 On-site Construction and Laying Specifications
- Construction Temperature: Cables must not be laid when the ambient temperature is below 0℃ to prevent brittle cracking of the insulation and sheath.
- Bending Control: Never forcibly bend or twist the cable. Follow the specified minimum bending radius to protect the internal insulation structure.
- Traction Operation: When pulling the cable, control the traction force evenly. Excessive tension can cause conductor deformation and armor displacement.
- Direct burial requirements: Lay a layer of fine sand around the cable and cover it with protective bricks or stone slabs to isolate the cable from sharp objects.
- Corrosive environment protection: Do not lay the cable in strong acid or alkali environments for extended periods. If corrosive media are present on site, a corrosion-resistant sheath must be installed.
- Terminal connections: Use dedicated connectors compatible with aluminum alloy conductors and standardize crimping and sealing processes to ensure a secure connection.
- 5.3 Procurement, Storage, and Acceptance Precautions
- Cables should be stored in a dry, ventilated, and cool warehouse, away from open flames, chemical reagents, and humid environments. Avoid prolonged open-air storage.
- Upon receiving the goods, inspect the cable's appearance, outer diameter, insulation integrity, and the clarity of markings. Randomly check product certificates and test reports to ensure batch quality consistency.
- The quantity of goods delivered should be arranged reasonably according to the construction schedule to avoid prolonged storage affecting cable performance.
- Fully Compliant with Standards: All products are manufactured strictly according to national standards, and all performance indicators have been tested by authoritative third-party institutions.
- Complete Certification Documentation: A complete set of documents is provided, including type test reports, flame retardant test reports, smoke and halogen test reports, and factory inspection certificates, supporting project bidding, on-site acceptance, and filing.
- Complete Quality Traceability: Each batch of products has complete production records, raw material inspection data, and delivery reports, enabling full-process quality supervision for large-scale projects.
- Consistent Batch Quality: Fully automated production lines and multi-stage inspection processes ensure consistent performance across batches, meeting the supply needs of long-term projects.
- Dual Adaptability: Complies with domestic engineering specifications and internationally recognized low-smoke halogen-free cable specifications, supporting both local projects and overseas procurement.
- Case 1: Urban Road and Underground Utility Tunnel Project
A large-scale urban integrated utility tunnel and road expansion project used YJLHV22 cables for direct burial throughout the entire route. The steel-tape armor can withstand long-term soil pressure and road load vibration. The cable has been operating stably for 7 years without any damage or failure. The project team highly recognized its durability and low maintenance costs.
- Case 2: Integrated Medical Park Power Distribution Project
A large medical park (including a general hospital, specialist clinics, and medical research buildings) used this cable as its main power line. Its low-smoke, halogen-free, and Class A flame-retardant properties fully meet the stringent fire protection requirements of medical facilities. The product successfully passed joint acceptance by multiple departments, ensuring uninterrupted power supply to medical equipment.
- Case 3: Large-scale Modern Industrial Park Project
A comprehensive industrial park integrating production, warehousing, and logistics selected YJLHV22 cables for workshop power distribution and outdoor buried trunk lines. Facing complex working environments such as equipment vibration, high humidity, and dust, the cable maintained stable operation throughout the year. The use of aluminum alloy materials effectively controlled the overall procurement budget of the project.
- Case 4: Integrated Transportation Hub Project
A large-scale transportation hub integrating subway, railway, and long-distance passenger transport used this cable to distribute power within enclosed passageways and station buildings. Its excellent flame retardancy and smoke suppression properties eliminated potential safety hazards in crowded, enclosed spaces. Its good flexibility simplified wiring work in dense cable wells and trunking, and shortened the construction period.
- Case 5: New Urban Area Municipal Supporting Project
This new urban area municipal supporting power supply project covered residential communities, landscape facilities, and public service buildings. YJLHV22 cable was widely used. Complete qualification documents simplified the bidding and acceptance process, and all laying methods, including buried, wall-mounted, and bridging, achieved good application results.

- Superior Raw Materials and Stable Quality: We use high-purity aluminum alloy raw materials and premium low-smoke halogen-free compounds, and are equipped with automated production equipment. From raw material warehousing to finished product delivery, we implement strict quality inspections to ensure the reliability of every cable.
- Customized One-Stop Service: In addition to standard specifications, we can also provide personalized customization services based on project design requirements, such as the number of core wires, cross-section, fixed length, and special sheaths, to meet different engineering solutions.
- Professional Technical Team Support: Our professional electrical engineering team provides free pre-sales selection, load calculation, and solution optimization services. During construction, we also provide on-site technical guidance to promptly resolve technical problems.
- Sufficient Inventory and On-Time Delivery: We maintain sufficient inventory of mainstream specifications to meet urgent orders and bulk supply needs. For large-scale, long-lead-time projects, we will develop dedicated production plans to ensure on-time delivery.
- Comprehensive Supporting Supply: We offer a full range of complementary cable accessories, connectors, and wire harnesses, enabling one-stop purchasing, simplifying the procurement process, and reducing management costs.
- Comprehensive Full-Lifecycle After-Sales Service: We establish dedicated project files for large orders. Our after-sales team continuously monitors product operation status and responds efficiently to inquiries and feedback.
- Optimal Overall Cost: We balance product quality, service, and price to help clients control project costs while ensuring project safety and stability, creating long-term value for our partners.