×
品質 NH-YJV 0.6/1kV Low Voltage Fire-resistant XLPE Power Cable for High-density Indoor & Emergency Load Projects 工場
品質 NH-YJV 0.6/1kV Low Voltage Fire-resistant XLPE Power Cable for High-density Indoor & Emergency Load Projects 工場
品質 NH-YJV 0.6/1kV Low Voltage Fire-resistant XLPE Power Cable for High-density Indoor & Emergency Load Projects 工場
品質 NH-YJV 0.6/1kV Low Voltage Fire-resistant XLPE Power Cable for High-density Indoor & Emergency Load Projects 工場
品質 NH-YJV 0.6/1kV Low Voltage Fire-resistant XLPE Power Cable for High-density Indoor & Emergency Load Projects 工場
品質 NH-YJV 0.6/1kV Low Voltage Fire-resistant XLPE Power Cable for High-density Indoor & Emergency Load Projects 工場

NH-YJV 0.6/1kV Low Voltage Fire-resistant XLPE Power Cable for High-density Indoor & Emergency Load Projects

製品仕様
原産地: 中国安徽省
ブランド名: JinHong
認定: CE、ROHS
モデル番号: NH-YJV
最低注文数量: 500M
価格: 15-32USD/m
納期: 30日間
支払い条件: T/T

製品概要

NH-YJV 0.6/1kV Fire-Resistant Low-Voltage Cable NH-YJV 0.6/1kV is a national standard fire-resistant low-voltage fixed-laying cable. Its structure consists of a high-purity copper conductor, an inorganic fire-resistant sheath, cross-linked polyethylene (XLPE) insulation, and a polyvinyl chloride ...

商品の説明

NH-YJV 0.6/1kV Fire-Resistant Low-Voltage Cable

NH-YJV 0.6/1kV is a national standard fire-resistant low-voltage fixed-laying cable. Its structure consists of a high-purity copper conductor, an inorganic fire-resistant sheath, cross-linked polyethylene (XLPE) insulation, and a polyvinyl chloride (PVC) outer sheath, with no steel tape armor.

NH Definition: The inorganic fire-resistant structure ensures continuous power supply under standard flame burning tests; YJV Definition: Cross-linked polyethylene insulation + PVC outer sheath.

Market Positioning: A preferred cable for critical load circuits in fire emergency situations, widely used in mid-to-high-end buildings, new energy, and municipal transportation projects; highly popular in domestic government tenders and bulk procurement in overseas markets such as Southeast Asia and the Middle East.

Complete Grade Technical Specifications and Full Size Range
Conductor Technical Specifications
Raw Materials: ≥99.97% electrolytic copper, conforming to IEC 60228 international standard
Conductor Type: Standard Category 2 tightly stranded copper conductor; Category 1 solid single-core copper wire, customizable, suitable for precision wiring projects
Core Wire Combinations: Seven mainstream core wire structures: 1C, 2C, 3C, 4C, 5C, 3+1C, 3+2C
Cross-sectional Area: In stock: 1.5~300mm²; Customized extra-large cross-section: 400~630mm²
Quality Control: The DC resistance of the finished conductor is strictly controlled below the standard upper limit to reduce long-term circuit power consumption.
Insulation Layer, Fire-Resistant Layer, and Outer Sheath
XLPE (Cross-Linked Polyethylene) Insulation Layer: Long-term allowable operating temperature 90℃, short-circuit instantaneous withstand temperature up to 250℃, low thermal deformation rate under high load.
Fire-Resistant Layer: Multiple layers of inorganic fire-retardant tape are wrapped between the conductor and the insulation layer; the core structure achieves fire resistance.
Outer Sheath: Anti-aging modified polyvinyl chloride (PVC), applicable ambient temperature -35℃~+70℃, moisture resistant, and resistant to slight acid and alkali corrosion.
Electrical and Fire Resistance Rating Parameters
Rated Voltage: U0/U=0.6/1kV
Factory Routine Withstand Voltage Test: 3.5kV/5min, no insulation breakdown.
Fire Resistance Rating: NH-A (fire resistance 180 minutes), NH-B (fire resistance 90 minutes), conforming to GB/T19666 international general fire resistance test standard.
NH-YJV 0.6/1kV Low Voltage Fire-resistant XLPE Power Cable for High-density Indoor & Emergency Load Projects 0
Differentiated Core Product Performance Highlights
  • Graded Fire Resistance
    Two selectable fire resistance grades meet different fire protection codes; fire pumps, emergency lighting, and other equipment can operate stably and continuously within the specified combustion time, meeting fire safety acceptance standards.
  • Superior High-Temperature Heat Dissipation
    XLPE insulation material has a dielectric loss far lower than traditional PVC insulation materials such as NH-VV, making it suitable for densely stacked wiring in cable shafts, avoiding aging caused by heat accumulation.
  • Lightweight Structural Advantages
    The unarmored streamlined cable body reduces the overall weight of the cable and the bending radius, significantly improving the efficiency of cable pulling in concealed conduits and high-rise vertical shafts.
  • Comprehensive Moisture Protection
    The integrated extruded outer sheath + tightly wrapped inner fire-resistant layer effectively prevents moisture penetration, suitable for damp basements, semi-buried cable trenches, and underground pipe racks.
  • Extra-Long Service Life
    Antioxidants and UV-resistant additives are added to the insulation layer and sheath, with a designed service life exceeding 35 years under standard installation conditions, reducing the investment for later circuit maintenance for project owners.
  • Stable and compact structure
    Low water absorption and environmentally friendly filler ensure the cable's rounded appearance and avoid damage caused by local insulation extrusion during on-site cable pulling.
Major Industrial Sectors + Detailed Segmented Application Scenarios
Super High-Rise and High-End Commercial Buildings

Application Scenarios: Fire elevator power supply, fire hydrant pump main circuit, and emergency evacuation lighting in super high-rise residential buildings, shopping malls, and luxury hotels; design institutes prioritize NH-A rating.

Medical and Government Public Works

Application Scenarios: Fire alarm linkage circuits in inpatient wards, fire alarm wiring in government office buildings, emergency backup power circuits in municipal hospitals, and main power supply for government-invested public construction projects.

New Energy Photovoltaic and Energy Storage Industry

Application Scenarios: Emergency power outage control cables for energy storage containers, fire auxiliary circuits for ground-mounted photovoltaic power stations, and dedicated wiring for BIPV (Building Integrated Photovoltaic) fire protection.

Large Transportation Hub Projects

Application Scenarios: Emergency power distribution lines in airport terminals, fire control cables in underground passages of high-speed railway stations, and evacuation power supply circuits in urban integrated bus stations.

Electronics and Light Industrial Factories

Application Scenarios: Power cables for exhaust fans in production workshops, fire alarm control circuits in factories, and exposed wiring in food processing and electronics manufacturing plants.

Core Engineer Reference: Design Matching and On-site Installation Standard Requirements
Fire Rating Selection Recommendations
  • NH-A: Super high-rise buildings, enclosed underground integrated pipe corridors, critical circuits for core medical emergency response
  • NH-B: Ordinary multi-story commercial buildings, conventional indoor factory fire protection circuits

Our technical team can provide free consultation services on matching local fire protection standards based on the project construction area.

On-site Laying Restrictions

Minimum bending radius ≥ 12 times the outer diameter of the finished cable; prevent sharp metal from scratching the outer sheath during pipe threading.

Dense Cabling Recommendations

Multi-layer bundled cables should have reasonable heat dissipation gaps; the factory provides current carrying capacity classification data for different laying methods for engineers to perform load calculations and cable selection.

Core Reference for Purchasers: Order Confirmation and Scientific Cost Control Guidelines
  • Strictly differentiate circuit characteristics: Only fire-fighting mandatory load circuits should use NH-YJV; general lighting and power circuits should use conventional YJV to avoid over-specification procurement and wasted funds.
  • Phased Construction Cooperation: Support phased delivery according to project construction progress to reduce the buyer's on-site warehousing costs and capital occupation.
  • Special Customization Requirements: For coastal salt spray areas and corrosive gas environments in workshops, enhanced anti-corrosion outer sheaths can be customized before ordering.NH-YJV 0.6/1kV Low Voltage Fire-resistant XLPE Power Cable for High-density Indoor & Emergency Load Projects 1
Multi-Regional Certification and Engineering Compliance Advantages
Domestic Certifications:
  • CCC Mandatory Certification
  • Full-Type Inspection Reports from National Authoritative Testing Institutions
  • Third-Party Fire Resistance Testing Certificates (Covering All Standards)
International Compliance:

IEC Standard Testing and Certification, Meeting the Bidding Standards and Access Rules for Engineering Projects in Southeast Asia, the Middle East, and Central Asia

Tendering Services:

All certification documents can be compiled into complete bidding materials to assist buyers in successfully passing the qualification review for domestic and international EPC bidding projects.

Global Engineering Application Cases
Case 1: Fire Protection Project for a New Municipal General Hospital in Saudi Arabia (2025)
A local EPC contractor procured 45 kilometers of mixed-specification NH-A grade NH-YJV type insulating tubing, ranging in size from 3×6mm² to 5×50mm², for use in the inpatient building's fire pumps and emergency lighting wiring. Local medical buildings strictly adhere to fire safety regulations, and all products passed third-party on-site fire safety inspections. Following project acceptance, both parties signed a long-term annual framework cooperation agreement.
Case 2: Auxiliary Fire Protection Circuit Project for a 180MW Centralized Energy Storage Park in China (2024)
A new energy company procured 32 kilometers of NH-B grade NH-YJV type insulating tubing for emergency power supply to energy storage cabinets. The compact indoor layout resulted in high ambient temperatures; the XLPE high-temperature resistant insulating tubing effectively prevented insulation overheating failure, and the entire project was completed and connected to the grid as planned.
Case 3: Emergency Power Supply Upgrade for High-Speed ​​Railway Station Expansion in China (2024)
The municipal procurement unit centrally procured 58km of multi-core NH-YJV type cables for the fire protection circuit in the underground corridor of the station; the lightweight characteristics made them suitable for dense indoor wiring, and all indicators passed the construction quality supervision and acceptance on the first attempt.
NH-YJV 0.6/1kV Low Voltage Fire-resistant XLPE Power Cable for High-density Indoor & Emergency Load Projects 2
Differentiated Factory Procurement Support Privileges
Pre-sales Technical Services for Design Engineers
  • Free assistance services including wire gauge selection, current carrying capacity verification, and bid technical parameter preparation;
  • Provide editable product data sheets and scanned copies of complete certification documents to shorten the design and bid document preparation cycle;
  • Accept production of non-standard cross-sections and custom-made sheaths for special environments.
Bulk Order Cost and Delivery Advantages
  • Factory direct supply, no middlemen markups; tiered preferential pricing for large-volume and long-term contract customers; ample inventory of copper and plastic raw materials effectively stabilizes order costs and mitigates raw material market fluctuations.
  • Standard specifications are in stock to meet the needs of urgent short-delivery orders; customized products can be arranged on dedicated production lines to shorten production cycles.
After-sales and bidding support:
  • Products meet national standards for quality assurance; on-site professional construction technical guidance is provided for large-scale projects;
  • Formal factory authorization letters and complete qualification documents are provided to help buyers improve their success rate in domestic and international engineering bids.
また好むかもしれない