×
Qualità Copper Conductor Low Voltage Cable Offering Excellent Conductivity and Mechanical Strength for Electrical Installations fabbrica
Qualità Copper Conductor Low Voltage Cable Offering Excellent Conductivity and Mechanical Strength for Electrical Installations fabbrica
Qualità Copper Conductor Low Voltage Cable Offering Excellent Conductivity and Mechanical Strength for Electrical Installations fabbrica
Qualità Copper Conductor Low Voltage Cable Offering Excellent Conductivity and Mechanical Strength for Electrical Installations fabbrica
Qualità Copper Conductor Low Voltage Cable Offering Excellent Conductivity and Mechanical Strength for Electrical Installations fabbrica
Qualità Copper Conductor Low Voltage Cable Offering Excellent Conductivity and Mechanical Strength for Electrical Installations fabbrica

Copper Conductor Low Voltage Cable Offering Excellent Conductivity and Mechanical Strength for Electrical Installations

Specifiche del prodotto
Luogo di origine: Anhui Cina
Marchio: JinHong
Certificazione: CE、ROHS
Numero di modello: YJLV22
Quantità minima di ordine: 1000M
Prezzo: 25-35USD/m
Tempi di consegna: 30 GIORNI
Termini di pagamento: T/T

Riepilogo Prodotto

YJLV22 is a standard steel-tape armored aluminum core power cable conforming to GB/T12706 and the harmonized IEC60502 industry standards. It features a five-layer structure: compacted pure aluminum conductor, cross-linked polyethylene (XLPE) insulation, PVC inner lining, double-overlapping steel ...

Descrizione del prodotto

YJLV22 is a standard steel-tape armored aluminum core power cable conforming to GB/T12706 and the harmonized IEC60502 industry standards. It features a five-layer structure: compacted pure aluminum conductor, cross-linked polyethylene (XLPE) insulation, PVC inner lining, double-overlapping steel tape armor layer, and PVC outer sheath. Unlike copper core YJV22 and alloy core YJLHV22 armored cables, this product uses high-purity electrical-grade aluminum as the conductive medium, achieving a balance between raw material costs and basic power transmission performance. Furthermore, it incorporates a steel tape armor layer specifically designed for installation environments susceptible to external mechanical shock, soil compaction, and damage from underground rodents (e.g., direct burial, trench backfilling, and road crossings). This product has gained widespread acceptance among municipal power design institutes, infrastructure EPC contractors, plant electrification retrofit investors, and major global power importers. Our production facilities can customize the shell formula and fine-tune the armor thickness according to the official construction drawings provided by our clients, and use non-standard core material combinations. All finished products undergo continuous certification testing in our factory laboratory to meet international tender document review and cross-border customs clearance requirements.

2. Complete Technical Specifications and Graded Core Wire Performance Indicators
2.1 Electrical Technical Parameters
Rated Voltage: Standard specification is 0.6/1kV low voltage; customized medium voltage specifications from 3.6kV to 35kV are available, suitable for substation interconnection buried lines.
Conductor Material: High-purity industrial aluminum rod compaction; customized anti-corrosion treated aluminum cores are available for projects in coastal saline-alkali land and chemically contaminated soil, with cross-sections ranging from 16mm² to 500mm².
Core Wire Configuration Options: Single-core, three-core, 3+1-core, four-core, 4+1-core, and other structural configurations are available, suitable for single-phase branch power supplies and three-phase four-wire main incoming line distribution designs in municipal and industrial power grids.
Insulation Electrical Performance: XLPE insulation maintains an insulation resistance of over 980MΩ·km at room temperature; controlling the conductor resistivity can stabilize power transmission performance and limit excessive voltage drop in long-distance buried trunk lines over 300 meters in large industrial clusters.
2.2 Mechanical and Armor Performance
Double-layer overlapping steel strip armor: The closed-loop protective layer effectively resists heavy backfill soil, accidental crushing by construction machinery, and gnawing by underground animals, significantly reducing the on-site cable damage rate compared to unarmored YJLV aluminum cables.
Optimized aluminum conductor stranding process: Multiple tight strandings enhance structural compactness, improve tensile strength, and reduce strand loosening and deformation caused by long-term settlement of buried pipelines.
Inner buffer layer: Isolates the rigid steel armor from the XLPE insulation layer, eliminating insulation wear caused by slight displacement of the armor due to seasonal surface deformation and external soil pressure.
2.3 Environmental Adaptability Indicators
Long-term continuous operating temperature: The XLPE insulation layer can operate stably at 90℃, and the instantaneous short-circuit peak withstand temperature reaches 250℃. Operating temperature range: -35℃~+72℃
Standard inherent environmental characteristics: Excellent waterproofness, ozone aging resistance, and resistance to general soil corrosion; the HDPE modified outer sheath can replace the ordinary PVC sheath and is suitable for underground laying environments in acid and alkali chemical industrial parks and coastal high salt spray environments.
Copper Conductor Low Voltage Cable Offering Excellent Conductivity and Mechanical Strength for Electrical Installations 0
Competitive Advantages Compared to Other Alternatives
  • Significant Raw Material Cost Optimization: Unit procurement costs are approximately 40%–55% lower than those of copper-core YJV22 armored cables of the same cross-section, resulting in significant cost savings for large infrastructure projects with tight material budgets.
  • Reduced Overall Weight: The total weight of the finished cable is approximately half that of a comparable copper-core armored cable, reducing land transportation costs and on-site hoisting and laying labor costs during concentrated construction phases.
  • Mature Industry Standardization: Large-scale standardized production shortens delivery cycles for standard specifications, supporting emergency replenishment needs to address unforeseen project construction adjustments.
3. Application Area Classification and Global Bulk Procurement Case Validation
3.1 Application Area Subdivision
  • Municipal Power Grid Upgrade and Renovation Projects: Underground trunk cable laying for converting overhead power lines to underground power grids in old urban areas; underground power layout for municipal road expansion and urban greenbelt power distribution networks crossing roads.
  • Industrial Park Construction: Laying underground main incoming cables for the power distribution networks surrounding mineral processing plants, light industrial parks, and chemical production bases.
  • Transportation Infrastructure: Underground power cabling along highway auxiliary facilities; outdoor fixed power pipelines around airports; and external power distribution projects for large railway stations.
  • Large-Scale Civil Engineering: Underground pipeline power distribution for ultra-large logistics warehouse clusters and supporting power projects for suburban new town residential complexes.
  • Special Geological Engineering: Power cabling for inland saline-alkali farmland transformation and rural power grid renovation projects in low-temperature frozen soil areas.
Copper Conductor Low Voltage Cable Offering Excellent Conductivity and Mechanical Strength for Electrical Installations 1
Three Real-World Global Project Collaboration Cases
  • Case 1: Southeast Asian Provincial Municipal Power Grid Upgrade Bidding Project
    An Indonesian municipal power contractor won a regional rural power grid upgrade project in 2025, ordering 427 kilometers of HDPE salt-resistant custom YJLV22 armored aluminum cable for roadside buried power conversion in tropical high-humidity soil environments. After more than a year of seasonal rainfall and soil erosion, no armor rusting or insulation damage occurred. The client also signed annual framework supply contracts with three surrounding counties for subsequent power upgrade plans.
  • Case 2: Eastern European Light Industrial Park Phase II Expansion EPC Project
    A Slovakian industrial park general contractor selected our company's standard-grade YJLV22 cable to replace the aging buried cable in the existing factory power grid upgrade project. The lower procurement cost and easy installation characteristics effectively reduced the total material expenditure of the project and arranged supplementary bulk orders for the buried power engineering of the new workshop.
  • Case 3: Procurement Cooperation for a New Agricultural Industrial Park in North Africa
    An Egyptian agricultural development company purchased 352 kilometers of YJLV22 4×120+1×70 armored aluminum cable for the construction of an underground power network for a large-scale modern farm in arid, high-temperature desert conditions. All products passed local power department inspection and were designated as the standard underground cable for subsequent agricultural development projects.
Copper Conductor Low Voltage Cable Offering Excellent Conductivity and Mechanical Strength for Electrical Installations 2
4. Manufacturer's Quality Control and Customized Service Advantages
4.1 Full-Chain Raw Material Inspection and Production Quality Control Management

All aluminum ingots are sourced from formally certified large-scale smelters and come with complete component testing certificates. Each batch of aluminum ingots undergoes resistivity, tensile strength, and dimensional sampling inspections before stranding. XLPE and PVC raw materials are all qualified petrochemical-grade materials, free of any recycled waste plastics. Steel strips undergo professional rust-proof pickling treatment before armoring. All finished cables undergo high-voltage withstand voltage, partial discharge, and armor continuity sampling tests before delivery; any unqualified finished products are scrapped and not shipped.

4.2 Engineer-Driven Customized Engineering Solutions

The company's in-house R&D laboratory strictly follows customer construction drawings, adjusting sheath formulations, armor thickness, and non-standard cross-sectional parameters to develop customized YJLV22 products suitable for extreme geological conditions, resistant to low temperatures and chemical corrosion. Depending on the construction team's on-site cutting habits, various packaging options can be configured, including export-grade wooden barrel packaging and industrial coil packaging, to reduce residual cable waste and optimize the overall project procurement expenditure.

4.3 Global Compliance and Complete Certification Advantages

We provide a full set of ISO9001 quality management system certification, authoritative third-party GB testing reports, and IEC conformity certification documents, along with complete English versions. All certification documents can be directly used for overseas government bidding qualification verification and customs clearance in the destination country, efficiently simplifying bidding and import administrative procedures for cross-border purchasers.

5. Professional Selection Guide and On-site Laying Specifications (For Engineers and Procurement Experts)
5.1 Pre-procurement Specification Selection Guide
  • Cross-sectional area calculation principle: Calculate the total design load current and actual buried line length based on the distribution diagram, reserving a 13%~22% cross-sectional area margin to compensate for the inherent voltage drop of aluminum conductors. For buried trunk lines exceeding 250 meters, upgrade to a larger cross-sectional area specification.
  • Environmentally Differentiated Selection Rules: Customized HDPE anti-corrosion outer sheath YJLV22 is used for projects buried in coastal saline-alkali land and chemical industrial parks; for municipal renovation projects in high-altitude permafrost areas, low-temperature modified sheath grade is selected.
  • Accessory Matching Reminder: When procuring auxiliary materials, please use dedicated aluminum crimp terminals instead of ordinary copper terminals to avoid electrochemical corrosion at cabinet connection nodes.
5.2 On-site Direct Burial Construction Standards and Specifications

Before backfilling, lay a fine sand layer under the cable to isolate sharp gravel from the outer sheath, preventing armor deformation and sheath puncture. When turning in the trench, the minimum bending radius specified in the standard should be followed to avoid damage to the inner structure. Buried lines should be kept away from underground high-temperature heat pipes to slow down the long-term aging of the sheath.

6. Core Advantages of Direct Procurement from Our Factory
  • Stable Delivery Arrangement: Three dedicated YJLV22 automated production lines and ample raw material inventory ensure that standard specifications of products are shipped within 10-17 working days after deposit confirmation, avoiding project stoppages due to material supply delays.
  • Factory Direct Sales Prices, No Middleman Markups: Large EPC bidding bulk orders can enjoy tiered bulk discounts, helping procurement managers optimize the overall project budget and improve the overall economic benefits of the project.
  • Full-cycle professional technical support: The company's experienced power cable engineering team provides free pre-sales load calculation and specification matching consultation, and offers remote technical troubleshooting guidance during customer on-site construction.
  • Flexible long-term cooperation models: Small-batch sample trial orders can be provided for on-site performance verification before large-scale bidding and procurement; long-term global distributors and engineering contractors can sign annual fixed-price framework contracts to mitigate cost fluctuation risks caused by international non-ferrous metal price volatility.
Potete inoltre gradire