×
Kwaliteit Copper Core Low Toxicity Fire Safe Wiring for High-end Public & Closed-space Engineering fabriek
Kwaliteit Copper Core Low Toxicity Fire Safe Wiring for High-end Public & Closed-space Engineering fabriek
Kwaliteit Copper Core Low Toxicity Fire Safe Wiring for High-end Public & Closed-space Engineering fabriek
Kwaliteit Copper Core Low Toxicity Fire Safe Wiring for High-end Public & Closed-space Engineering fabriek
Kwaliteit Copper Core Low Toxicity Fire Safe Wiring for High-end Public & Closed-space Engineering fabriek
Kwaliteit Copper Core Low Toxicity Fire Safe Wiring for High-end Public & Closed-space Engineering fabriek

Copper Core Low Toxicity Fire Safe Wiring for High-end Public & Closed-space Engineering

Productspecificatie
Plaats van herkomst: Anhui China
Merknaam: JinHong
Certificering: CE、ROHS
Modelnummer: WDZA-YJY
Minimale bestelhoeveelheid: 500M
Prijs: 15-30USD/m
Levertijd: 30DAGEN
Betalingsvoorwaarden: T/T

Productoverzicht

WDZA-YJY 0.6/1kV is a Class A low-smoke halogen-free flame-retardant low-voltage power cable conforming to GB and IEC LSZH standards. Model Description: WDZA = Low-smoke halogen-free + Class A high-grade flame retardant; YJY = XLPE insulation + LSZH outer sheath. All insulation and sheathing are ...

Productbeschrijving

WDZA-YJY 0.6/1kV is a Class A low-smoke halogen-free flame-retardant low-voltage power cable conforming to GB and IEC LSZH standards.

Model Description: WDZA = Low-smoke halogen-free + Class A high-grade flame retardant; YJY = XLPE insulation + LSZH outer sheath. All insulation and sheathing are made of halogen-free environmentally friendly polymer materials, without added halogen raw materials.

Structure: High-purity dense copper conductor + XLPE insulation layer + environmentally friendly halogen-free filler + low-smoke halogen-free outer sheath, no flame-retardant inorganic coating layer, no metal armor.

Market Positioning: Suitable for mandatory wiring in confined spaces, large public buildings, and high-standard new energy projects with strict requirements for smoke and toxic gas control; mainstream bidding cables for airports, subways, integrated pipe corridors, high-end hospitals, and landmark commercial complexes; widely exported to high-standard infrastructure procurement markets in Europe, Southeast Asia, and the Middle East.

2. Complete Layered Technical Parameters and Specifications
2.1 Conductor Technical Specifications

Raw Materials: ≥99.97% electrolytic copper, conforming to IEC60228 standard; Two options: Category 1 solid round copper, Category 2 tightly stranded copper

Core Wire Combination: 1C/2C/3C/4C/5C/3+1C/3+2C seven-core structure

Cross-section Range: Standard stock: 1.5mm²~300mm²; Extra-large custom specifications: 400~630mm², suitable for special high-current projects

Quality Control: The DC resistance of the finished conductor is strictly lower than the standard upper limit to suppress long-term circuit power loss.

2.2 Insulation, Filler, and Outer Sheath Parameters

XLPE Insulation: Long-term allowable operating temperature 90℃, short-circuit instantaneous withstand temperature up to 250℃, low thermal deformation, maintaining stable insulation performance even under high-density bundled heat accumulation.

Inner Filler: Halogen-free, low-smoke, environmentally friendly filler material, low water absorption, maintains cable roundness under open flame and does not release toxic fumes.

Outer Sheath: Special low-smoke, halogen-free modified polyolefin sheath, applicable ambient temperature: -30℃~+70℃, with excellent anti-aging, moisture-proof, and mild chemical corrosion resistance, zero halogen content.

2.3 Electrical and Flame Retardant Testing Standards

Rated Voltage: U0/U=0.6/1kV

Factory Power Frequency Withstand Test: 3.5kV/5 minutes without breakdown

Fire Resistance: Class A flame retardant + low-smoke, halogen-free characteristics; smoke density and toxicity index meet national authoritative testing standards for low-smoke, halogen-free materials.

Copper Core Low Toxicity Fire Safe Wiring for High-end Public & Closed-space Engineering 0

3. Seven Core Product Performance Advantages
3.1 Ultra-Low Smoke Emission Characteristics

When exposed to open flame, it produces only a small amount of light smoke, not dense black smoke; ensuring visibility in fire evacuation areas such as enclosed tunnels, underground alleys, and dense cable shafts, significantly improving the safety of personnel escape.

3.2 Halogen-Free and Non-Toxic Combustion Characteristics

The raw materials do not contain halogen elements such as chlorine and bromine; it does not release toxic or corrosive halogen gases during combustion, avoiding equipment corrosion and personnel poisoning, and meeting high standards of environmental protection and fire protection regulations.

3.3 Class A Advanced Flame Retardant Performance

Class A flame retardant performance effectively prevents the vertical spread of flames along the cable trunk line; under conditions of dense multi-row bundled laying, it effectively limits the spread of fire, superior to ordinary ZB/ZC grade flame retardant cables.

3.4 Excellent High-Temperature Insulation Stability

XLPE insulation performance is superior to PVC insulated cables, with low dielectric loss, making it suitable for densely stacked cabling in enclosed cable shafts with poor natural heat dissipation.

3.5 Environmentally Friendly Raw Materials

The entire cable contains no harmful halogens or heavy metal additives, meeting international green building material certification requirements and making it an ideal choice for LEED green building projects.

3.6 Lightweight and Flexible Installation Performance

The unarmored streamlined structure offers moderate bending performance, facilitating pre-embedded conduit installation and high-rise vertical shaft cabling, reducing on-site labor input.

3.7 Extra-Long Service Life

The LSZH sheath incorporates antioxidant and UV-resistant formulations, achieving a nominal design service life exceeding 35 years under standardized installation conditions, reducing subsequent renovation costs for project owners.

4. Five Major Industry Sectors + Detailed Application Scenarios
4.1 Rail Transit and Underground Integrated Pipe Gallery

Scenario: Public power distribution circuits in subway stations, general power cabling in underground public tunnels, power supply for subway auxiliary equipment; WDZA-YJY cables are mandated by design institutes for enclosed spaces.

4.2 Airport and Large Transportation Hub Construction

Scenario: Public lighting in airport terminals, auxiliary power distribution in waiting halls, conventional power loops in underground passages; LSZH Class A flame-retardant cables are commonly used in large transportation infrastructure.

4.3 Grade A Hospitals and High-End Public Medical Buildings

Scenario: Public power supply for inpatient wards, auxiliary power distribution cabling for medical equipment, fixed laying of underground cable trenches in hospitals; medical buildings have strict regulations for controlling toxic gases in case of fire.

4.4 Landmark Commercial Complexes and Super High-Rise Green Buildings

Scenario: Public power trunk lines in super high-rise office buildings, power distribution circuits in shared areas of large shopping malls, fixed cabling within green-certified commercial real estate.

4.5 Energy Storage and Large-Scale Photovoltaic New Energy Projects

Application Scenarios: Non-emergency auxiliary power circuits for energy storage containers; indoor centralized power distribution wiring for ground-mounted photovoltaic power stations; low-smoke, non-toxic cables are required for enclosed equipment rooms in new energy parks.

Copper Core Low Toxicity Fire Safe Wiring for High-end Public & Closed-space Engineering 1
5. Key Specifications for Design Matching and On-Site Installation for Engineers

Grade Selection Standards: WDZA complete cable set is used for enclosed tunnels, underground pipe corridors, Class A hospitals, and core areas of super high-rise buildings; for open-air ordinary factories, WDZB/YJY can be downgraded to optimize project costs. Our technical team provides free consultation services on matching local fire protection regulations.

Laying Construction Restrictions: Minimum bending radius ≥ 12 times the outer diameter of the finished cable; during cable pulling, prevent sharp pipe ends from scratching the low-smoke, non-toxic cable sheath.

Dense Shaft Laying Tips: When laying in multiple layers of bundles, maintain a fixed heat dissipation gap; the manufacturer provides current carrying capacity data tables for different laying methods for engineers to calculate loads and select cables.

6. Buyer-Oriented Order Selection and Scientific Budget Control Guidelines

Reasonable Model Division: Strictly distinguish between enclosed, sealed spaces and open, general spaces; configure WDZA-YJY only for enclosed high-fire-risk areas, and select standard YJV for open, non-critical areas to reduce duplicate procurement costs.

Phased Construction and Delivery: Support phased delivery according to project construction progress, reducing on-site warehousing costs and capital tied up for the buyer.

Customized Upgrade Services: For coastal high-salt-spray environments, salt-spray-resistant enhanced LSZH sheaths can be customized before formal ordering.

Advantages in Cross-Border Standard Certification and Engineering Compliance

Domestic Qualifications: CCC mandatory certification, national authoritative third-party LSZH and flame retardant full-type test reports, low smoke toxicity test certificate.

International Compliance: Complies with IEC60332 and IEC61034 international LSZH testing standards, meeting the green building bidding requirements of the EU, Southeast Asia, and the Middle East.

Bidding Assistance: Complete certification materials can be compiled into formal bidding documents, assisting buyers in successfully passing government bidding qualification reviews and overseas high-standard EPC project assessments.

Three Real-World Engineering Application Cases from Home and Abroad
Case 1: Power Distribution Project for a New International Airport Terminal in the Middle East (2025)

The local EPC contractor procured 82 kilometers of mixed-specification WDZA-YJY series cables, ranging in size from 3×6mm² to 4×185mm², for indoor public power distribution in the terminal building. Local aviation construction strictly adhered to Low Smoke Non-toxic (LSZH) fire safety standards; all products passed third-party on-site smoke density testing. A long-term annual framework cooperation contract was signed after project acceptance.

Case 2: Power Distribution Project for an Underground Utility Tunnel in a New Metro Line in China (2024)

The municipal rail transit procurement department centrally procured 67 kilometers of WDZA-YJY series multi-core cables for conventional power distribution inside the tunnel. The tunnel environment was enclosed, requiring the cables to have low smoke and non-toxic characteristics. All testing indicators passed the construction quality supervision and acceptance.

Case 3: Indoor Auxiliary Cabling Project of a Large-Scale Shared Energy Storage Park in China (2024)

A new energy company purchased 43 kilometers of WDZA-YJY cable for the auxiliary power circuit of the energy storage equipment room; low-smoke halogen-free cables were used in the indoor enclosed equipment room, and the entire project was successfully completed and connected to the grid as planned.

Copper Core Low Toxicity Fire Safe Wiring for High-end Public & Closed-space Engineering 2
Factory-Specific Customized Procurement Support and Cooperation Advantages
Providing Pre-sales Technical Support for Design Engineers
  • Free auxiliary services including specification selection calculation, current carrying capacity check, and bidding technical parameter sorting; providing editable PDF data sheets and a complete set of scanned certification documents.
  • Customized production of low-smoke halogen-free sheaths for non-standard cross-sections and special environmental modifications can be accepted according to the actual project situation.
Bulk Procurement Cost and Delivery Advantages
  • Direct supply from the factory, no middlemen markups; tiered preferential pricing for large-volume and long-term contract customers; stable inventory of copper and low-smoke halogen-free raw materials, reducing the impact of raw material price fluctuations.
  • Mainstream standard specifications are in stock to meet urgent short-term order needs; customized specifications can be arranged with dedicated production lines to shorten production cycles.
After-sales and Bidding Assistance Services
  • All products comply with national standard quality assurance; professional technicians can be arranged to provide on-site construction and wiring guidance for large-scale landmark projects.
  • Issuing formal factory authorization letters and complete qualification documents to increase the buyer's chances of winning bids in high-standard domestic and international engineering projects.
U mag ook van houden