1.5mm2 إلى 400mm2 كابل مقاوم للحريق NH-VV كابل الطاقة PVC 0.6/1kV
NH-VV Fire Resistant PVC Power Cable 0.6/1kV for Emergency Power Circuits NH-VV is a fire-resistant low-voltage power cable designed, according to relevant standards, to maintain circuit integrity and operate continuously for a period of time during fire exposure. It is commonly used in emergency and life-safety power circuits requiring continuous circuitry, such as emergency lighting feeders, fire pump power supplies, smoke exhaust fans, critical ventilation systems, and
كابل مقاوم للحريق بـ 5 نوى ZC-VV22 كابل طاقة مدرع PVC 0.6/1kV
ZC-VV22 PVC Armored Power Cable 0.6/1kV for Tough Fixed Installations ZC-VV22 Flame-Retardant Armored Power Cable ZC-VV22 is a low-voltage PVC-insulated, PVC-sheathed, steel-tape armored power cable designed for fixed installation routes requiring enhanced mechanical protection and superior flame retardancy. It is commonly used in underground conduits, trenches, cable corridors, and building inlets, locations where external pressure, backfill stress, or field handling risks
ZR-YJV22 كابل مدرع XLPE 12/20kV كابل مقاوم للحريق للاستخدام تحت الأرض
ZR-YJV22 Flame-Retardant Armored XLPE Power Cable 0.6/1kV for Underground ZR-YJV22 is a low-voltage copper core power cable that combines flame-retardant properties with steel tape armor, providing enhanced mechanical protection in fixed installations. This cable is commonly used in lines requiring increased fire safety and protection against compression and external stresses, such as underground conduits, trenches, cable corridors, building inlets, and industrial distributio
كابل مضاد للحريق ZR-YJV 0.6/1kV إلى 33kV كابلات مقاومة للحرارة
ZR-YJV Flame-Retardant XLPE Power Cable 0.6/1kV for Safer Cable Routes ZR-YJV is a low-voltage copper core power cable with a flame-retardant design that helps limit the spread of flame along the cable's path, making it ideal for building wiring and industrial installations, especially in locations where fire safety requirements specify the use of flame-retardant cables. It typically features copper conductors, cross-linked polyethylene (XLPE) insulation, and a sheath system
كابل نحاسي XLPE مقاوم للحريق 500 فولت NH-YJV 4 نوى 5 نوى كابل مقاوم للحريق
NH-YJV Fire-Resistant XLPE Copper Power Cable for Emergency Feeders NH-YJV is a fire-resistant low-voltage copper core power cable designed for emergency feeders and critical distribution lines that, according to relevant standards, must remain energized for a period of time under fire conditions. It features cross-linked polyethylene (XLPE) insulation to ensure stable thermal and electrical performance, and a dedicated fire-resistant layer to help maintain circuit integrity
3.6/6kV 6/10kV كابل XLPE المقاوم للنار NH-YJV لمغذيات الطوارئ
NH-YJV Fire Resistant XLPE Power Cable 0.6/1kV for Emergency Feeders NH-YJV is a fire-resistant low-voltage cross-linked polyethylene (XLPE) power cable designed to maintain circuit integrity and operate continuously for a period of time during fire exposure, in accordance with applicable standards. It is typically used in emergency and life-safety power circuits to ensure power continuity for evacuation and firefighting operations. NH-YJV features copper conductors, XLPE
أسلاك دوائر القيادة في حالات الطوارئ المقاومة للحريق، كابل تحكم متعدد النوى NH-KVV
NH-KVV Fire Resistant Multi-Core Control Cable for Emergency Command Circuits NH-KVV is a fire-resistant multi-core control cable used to ensure the continued operation of critical control, monitoring, and command circuits during a fire, according to specified standards and required durations. It is widely used in emergency system interlocking and control cabling in buildings, transportation facilities, and industrial sites where circuit continuity is a critical component of
كابل تحكم NH-KVV المقاوم للحريق لدوائر التحكم ذات الجهد المنخفض الحرجة
NH-KVV Fire-Resistant Control Cable for Critical LV Control Circuits NH-KVV Fire-Resistant Control Cable NH-KVV is a fire-resistant control cable designed to maintain control and command circuits for a specific period of time under fire conditions, the exact duration depending on applicable standards. It typically consists of copper conductors, a fire-resistant layer (usually mica-based), PVC insulation, and a PVC outer sheath. Therefore, NH-KVV is ideal for emergency control